Hubbell GAI-TRONICS 293-003 Manual Download Page 10

P

AGE 

9 of 19

S.M.A.R.T. ADA-C

OMPLIANT 

E

MERGENCY 

P

HONES

42004-351H

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-351h.doc
02/05

Setup

Hardware Configuration

The hardware configuration options are explained in detail in the following sections, and the necessary
jumper settings are identified to enable or disable each option.  We recommend reading each section,
recording the selected options, making the necessary changes, and creating a record of your settings.  See
Figure 7 on page 10 for the jumper locations.

Auto-answer Configuration

Factory Setting

:  Auto-answer feature enabled

The Auto-answer feature enables or disables the automatic answering of an incoming call, which allows
TMA to monitor the health of this phone via polling.  When the Auto-answer feature is enabled, the
phone automatically answers the call and attempts to communicate with TMA.  If the caller is not TMA,
then the phone rings its sounder to alert a user to lift the handset off-hook.

Enable

:  Insert the J14 jumper on pins 2 and 3.

Disable

:  Insert the J14 jumper on pins 1 and 2  (Do not use this setting except under the direction of

GAI-Tronics personnel.)

N

OTE

:

  The Auto-answer feature must be enabled during remote programming, and to allow the

GAI-Tronics Telephone Management Application PC to contact the phone.

Polarity Configuration

Factory Setting

:  Non-polarity sensitive

This telephone can be configured to be polarity or non-polarity sensitive.  With the non-polarized setting,
the telephone regardless of tip and ring polarity.  With the polarized setting, the telephone only operates
with the telephone line’s positive terminal connected to the tip.  Use the Polarity Sensitive setting to allow
a line voltage reversal disconnect signal to disconnect the call.

Non-polarity Sensitive

:  Insert the J6 jumper on pins 2 and 3.

Polarity Sensitive

:  Insert the J6 jumper on pins 1 and 2.

Summary of Contents for GAI-TRONICS 293-003

Page 1: ...ng an Emergency Call from a S M A R T Phone All Models 3 Placing a Non Emergency Call Models 294AL 003 and 298 003 Only 3 Receiving a Call 3 Disconnecting Calls 3 Installation 4 Safety Guidelines 4 Ge...

Page 2: ...ncy push button call push button standard telephone keypad Braille tag and visual call received indicator 297 003 Flush mount stainless steel front panel including an emergency push button Braille tag...

Page 3: ...mber i e a busy signal or no answer the emergency phone will automatically dial the first backup or roll over number Again in the event an emergency call cannot connect to first backup telephone numbe...

Page 4: ...eady PlacingaNon EmergencyCall Models294AL 003and298 003Only To place a non emergency call 1 Press the CALL push button 2 Wait for dial tone 3 Use the keypad to dial the desired number 4 At the end of...

Page 5: ...not touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface The Model 40404 045 Power Supply must be connected to an ac source within 4...

Page 6: ...e enclosure for cable entry For example if conduit is installed create an access hole using a Greenlee type punch that is equivalent in size to the conduit diameter 5 When the telephone line has been...

Page 7: ...19 S M A R T ADA COMPLIANT EMERGENCY PHONES 42004 351H s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 351h doc 02 05 Figure 3 Model 293 003 293AL 003 and 294AL 003 Component...

Page 8: ...back of the enclosure and connect the pre installed modular plug to the jack 4 Using the Setup section of this manual Make hardware configuration changes See the Hardware configuration section on page...

Page 9: ...E 8 of 19 S M A R T ADA COMPLIANT EMERGENCY PHONES 42004 351H s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 351h doc 02 05 Figure 6 Model 297 003 and 298 003 Mounting Detai...

Page 10: ...call and attempts to communicate with TMA If the caller is not TMA then the phone rings its sounder to alert a user to lift the handset off hook Enable Insert the J14 jumper on pins 2 and 3 Disable In...

Page 11: ...phone adjustments are made using potentiometers on the emergency phone PCBA R106 is the speaker volume adjustment and R88 is the microphone sensitivity adjustment Refer to Figure 7 for the potentiomet...

Page 12: ...g any volume adjustments we recommend mounting the front panel to the enclosure and again testing the phone Auxiliary Output Each telephone includes one isolated solid state switch capable of switchin...

Page 13: ...changed we recommend writing down the key sequence from the Command column of Table R 1 Basic Programming Commands Having the programming information written down allows you to enter the key sequence...

Page 14: ...1 command to program these three auto dial numbers The three auto dial telephone numbers are labeled as 11 primary 12 first roll over and 13 second roll over You can program these for three different...

Page 15: ...g is completed and the phone placed back on hook the following process must be followed For single button emergency phones 1 Remove the phone from the back box or enclosure 2 Disconnect the emergency...

Page 16: ...t duration multiply the desired time limit in minutes by 120 For example to determine the call duration entry for a call time out of five 5 minutes do the following 5 minutes 120 600 To enter a call t...

Page 17: ...d through the use of the maintenance access PIN The maintenance access PIN should be distributed only to trained maintenance personnel If your S M A R T Phone requires service contact your GAI Tronics...

Page 18: ...to 60 C Relative humidity to 95 no condensation Model 293 003 Enclosure construction Valox high impact glass reinforced polyester painted safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203 2 101...

Page 19: ...n Canada IC Certification Number 882B GTC S M A R T Ringer Equivalence Number 4B Connection Method CA11A Replacement Parts Part No Description 293 003 293AL 003 294AL 003 297 003 298 003 233 Model 233...

Page 20: ...d equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications...

Page 21: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Reviews: