Approvals

Safety of Information Technology Equipment ...................................................................... UL/CSA 60950

Enclosures for Electrical Equipment..................................................................................... UL 50, Type 3R

47 CFR Part 68

Certification Number .......................................................................................... US: ADGTE04B0414HAC

Ringer Equivalence Number..................................................................................................................... .4B

Network connection (USOC).................................................................................................................. RJ11

IC Information (Canada)

IC Certification Number ............................................................................................882B-GTC S.M.A.R.T.

Ringer Equivalence Number..................................................................................................................... .4B

Connection Method.............................................................................................................................CA11A

Replacement Parts

Part No.

Description

293

-001

293AL

-001

294AL

-001

297

-001

298

-001

233-001

Model 233-001 Tamper-Resistant
Screwdriver

„

„

„

„

„

12562-102

Emergency PCBA Replacement Kit
(Standard)

„

„

„

„

„

51035-005

PCBA, Keypad, metallic

„

„

28299-007

Tamperproof Screws
(Flush-mount models)

„

„

28229-004

Tamperproof Screws, 1-1/8 inch

„

„

„

12520-006

Push Button Replacement Kit
(1.5-inch, red)

„

„

„

„

„

12520-007

Push Button Replacement Kit
Black

„

„

40404-045

Plug-in Power Supply

„

„

„

„

„

12521-001

Microphone Replacement Kit

„

„

„

„

„

12522-003

Speaker Replacement Kit

„

„

„

„

„

51035-011

Keypad, plastic
(also used for local programming)

„

„

„

61504-048

Keypad Cable Assembly
(also used for local programming)

„

„

„

„

„

Summary of Contents for GAI-TRONICS 293-001

Page 1: ...298 001 Only 3 Americans with Disabilities Act ADA Functionality 4 Installation 5 Safety Guidelines 5 General Installation Guidelines 5 Tamper Resistant Hardware 5 Conduit Installation Details 6 Model...

Page 2: ...cast aluminum enclosure painted safety yellow that is designed to be surface mounted and includes a 12 button Braille keypad an emergency push button and a call off hook button 297 001 Flush panel Em...

Page 3: ...uration Answering options All of the above telephones are line powered telephones and can be connected to any of the following Central Office CO line to the Public Switched Telephone Network PSTN 24 V...

Page 4: ...1 2 The emergency operator must press the key to acknowledge the call 3 Once acknowledged the CALL RECEIVED WHEN LIT lamp on the phone s front panel illuminates and communication can begin PlacingaNon...

Page 5: ...The telephone detects the DTMF signal and transmits a three digit location identification code to identify which emergency telephone is originating the call This location code can be displayed on a D...

Page 6: ...ith the phone Please consult our Service Center at 800 492 1212 for further information Do not install telephone jacks in wet locations unless the jack is specifically designed for wet locations Do no...

Page 7: ...e enclosure from the bottom Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries Please refer to the exa...

Page 8: ...e Refer to conduit installation details on page 6 NOTE Use silicone sealant or equivalent around and inside all conduit entries 4 Pull the telephone line through the conduit Connect the telephone line...

Page 9: ...ANT EMERGENCY PHONES PAGE 8 of 29 d standard ioms current release 42004 instr manuals 42004 352k doc 06 06 Figure 6 Model 293AL 001 Figure 7 Model 294AL 001 Figure 8 Models 293 001 293AL 001 and 294AL...

Page 10: ...e telephone line and cable fitting 4 Telephone line connections directly to TB1 are acceptable 5 If using the modular jack remove the cover and connect the red and green wires of the telephone line to...

Page 11: ...PUB 42004 352K ADA COMPLIANT EMERGENCY PHONES PAGE 10 of 29 d standard ioms current release 42004 instr manuals 42004 352k doc 06 06 Figure 11 Model 297 001 and 298 001 Mounting Details...

Page 12: ...ase 42004 instr manuals 42004 352k doc 06 06 Figure 12 Model 297 001 and 298 001 Component Locations shown with connection to optional GAI Tronics 530FB 531A Beacon Connecting a Beacon Figure 12 above...

Page 13: ...pins 2 and 3 Disable Insert the J14 jumper on pins 1 and 2 Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled during remote progr...

Page 14: ...to Figure 13 for the location of TB2 The auxiliary output allows peripheral equipment such as beacons video cameras and alarm generators to be activated when the EMERGENCY push button is pressed The r...

Page 15: ...en the front panel is tightly mounted in the enclosure After making any volume adjustments we recommend mounting the front panel to the enclosure and testing the phone again Automatic Line Level Compe...

Page 16: ...Disconnect the keypad from J13 12 Install the phone in the back box or enclosure For emergency phones with a CALL push button and keypad Disable password protection by removing the jumper from J9 1 P...

Page 17: ...mper on pins 2 and 3 3 Using a touch tone telephone call the emergency telephone The emergency telephone automatically answers the call and generates a splash tone followed by a success tone single be...

Page 18: ...See Figure 8 and Figure 12 for details Contact GAI Tronics Field Service Department for details 2 Temporarily move the EMERGENCY push button switch harness from connector J7 to the CALL push button co...

Page 19: ...ameters See the Programming Sequences section below A success tone single tone DTMF tone is generated each time a new parameter is accepted An error tone double beep is generated to indicate an error...

Page 20: ...he first backup or roll over number Again in the event an emergency call cannot connect to first back up telephone number the emergency phone will automatically dial the second backup or roll over num...

Page 21: ...sequence ends in 2 instead of 1 None Emergency Button Auto dial Number 3 DD 3 Same as Emergency Button Auto dial Number 1 except the sequence ends in 3 instead of 1 None Call Button Auto dial DD 4 Sa...

Page 22: ...oringFeature When the Silent Monitoring feature is enabled the splash tone is eliminated and silent monitoring can begin without notifying individuals near the telephone Feature Key Sequence Descripti...

Page 23: ...sconnect Option 1 2 N N This feature programs the maximum length of a call if no other disconnect features are used The valid entries are 1 99 representing 1 minute increments and 0 representing 4 5 h...

Page 24: ...es the three digit location identification ID number To enable the ID feature set L 1 To disable the ID feature L 0 Enter the three digit location identification code in the sequence N N N For Example...

Page 25: ...gency Button Auto dial Number 2 DD 2 None Emergency Button Auto dial Number 3 DD 3 None Call Button Auto dial Number DD 4 None Primary Dial Tone Delay 10NN Infinite Secondary Line Dial Tone Delay 11NN...

Page 26: ...authorization number RA Equipment should be shipped prepaid to GAI Tronics with a return authorization number and a purchase order number If the equipment is under warranty repairs will be made witho...

Page 27: ...n PCBA printed circuit board assembly Conformal coated Model 293 001 Enclosure construction Valox high impact glass reinforced polyester painted safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203...

Page 28: ...er 4B Connection Method CA11A Replacement Parts Part No Description 293 001 293AL 001 294AL 001 297 001 298 001 233 001 Model 233 001 Tamper Resistant Screwdriver 12562 102 Emergency PCBA Replacement...

Page 29: ...ble is experienced with this equipment GAI Tronics telephone for repair or warranty information please contact GAI Tronics Corporation at 800 492 1212 or www gai tronics com If the equipment is causin...

Page 30: ...ide and contains sensitive business and technical information that is confidential and proprietary to GAI Tronics GAI Tronics retains all intellectual property and other rights in or to the informatio...

Page 31: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: