background image

ATTENTION!  Wiring Instructions:  If your fixture is equipped with a multi-tap ballast and if no voltage was 
specified on the purchase order, the ballast has been wired for operation on a 277 volt circuit (347v in Canada).  

If other than 277volts is required, i.e.; 120v, 208v, 240v, connect incoming voltage lead to required voltage on terminal

block.

AFL20 – Architectural Floodlight 

Installation Instructions

P.O. Box 60080 • 16555 East Gale Ave.

City of Industry, California 91716-0080

626/968-5666 • FAX 626/330-3861

WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.  

Failure to do so may result in serious personal injury.

MAINTENANCE: To maintain light efficiency and prevent fixture overheating, lenses must be kept clean and

free of dirt, dust, leaves, trash and mineral deposits from water. For optimum performance a regularly

scheduled maintenance program should be followed.
LAMP NOTE: All lamps must be rated for “Universal Burning Position” because fixture tilt changes lamp

orientation.  DO NOT operate luminaire with missing or damaged lens.
CAUTION:  All wiring should be done by a qualified electrician.  KEEP THIS SHEET FOR FUTURE REFERENCE.
FIXTURE IS APPROVED FOR ABOVE GRADE INSTALLATION ONLY.   

Revised 3/26/12        ECN 120326011          Status 15                                                                       

  

  

  

  

  

  

  

  

  

  

  

  

  

 

  

Part No. 95450

Housing Gasket

Housing

Stop Ar

Swivel Bolt

Swivel Spacer

m

Slip Hinge

Pins

Lens Frame

Ballast

J

-20 x 3

K

" Lg. Hex

Socket Cap Screws

(

F" 

A

llen Wrench)

Lens and Lens Gasket

~

Reflector

Captive Reflector 

Mounting Screws

(4)10-32 x 

K

" Lg.  

(Phillips screwdriver)

AFL22 lamp position shown. See

catalog for AFL21, 23, 24, 25, 26

C

- 16 

Set Screw

Tenon Mount Swivel

!

Tools Required:

F

" Allen Wrench

3

32

" Allen Wrench

L

" Socket and Ratchet

AFL21 Horizontal Flood
AFL22 Vertical Flood
AFL23 Medium Flood
AFL24 Narrow Flood
AFL25 Spot
AFL26 Narrow Spot

MOUNTING: The AFL20  mounts to any 2

"

pipe tenon (2

C"

O

.

D

. x 4

K"

minimum length).  Refer to optional mounting device instructions for
attachment to conduit system.

!

Reviews: