Pub. 42004-645L2C
Model 723-801 SmartSeries
®
Remote Subset Amplifier
Page: 9 of 15
d:\standard ioms - current release\42004 instr. manuals\42004-645l2c.doc
01/04
Internal Adjustments
Station Address for SmartSeries
®
Systems
To set the station address HI and LO (on the Base-24 PCBA), perform the following steps:
1.
Loosen the 4 captive screws that secure the front panel.
2.
Locate the address controls.
3.
Use the rotary switch labeled
HI ADDR
(on the Base-24 PCBA) to set the 1
st
digit of the hexadecimal
address (for example, the A in address A6). Use the rotary switch labeled
LO ADDR
(on the Base-24
PCBA) to set the 2
nd
digit of the hexadecimal address (for example, the 6 in address A6) of the station
address.
Note
: During configuration, each station is assigned a unique address. The address may
only be set to the value assigned in the system configuration. It is recommended that this address be
marked on the enclosure for future reference.
4.
Plug the amplifier into the enclosure.
5.
Setting the station address to the correct value, and re-installing the amplifier causes the station to
initiates a configuration download request. The time required to complete the download depends
upon system configuration and system activity, but several seconds is typical.
6.
When you are done with the adjustment, tighten the 4 screws.
Station Address for Page/Party
®
Systems
To set the station address HI and LO (on the Base-24 PCBA), perform the following steps:
1.
Loosen the 4 captive screws that secure the front panel.
2.
Locate the address controls.
3.
Set the address on the replacement assembly to 04 (HI = 0, LO = 4) and plug it into the enclosure.
4.
When you are done with the adjustment, tighten the 4 screws.
Although they typically do not require adjustments, the following internal adjustments can be made:
Audio Transmit Level, Handset Receiver Volume, Tone Volume, and Station Reset.