background image

6

Figure 1

Figure 2

The cursor can be moved between Current selection, Phase splitting, Winding

temperature, Conversion temperature, Data query, Clock modification, Host

parameters and other options by pressing the cycle key. The selection key can be

used to select the options contained in the seven main menus mentioned above.

When the cursor chooses the current, press the selection key to select the current.

When the cursor is separated, when the cursor is separated, press the select key,

and the phase can be displayed cyclically between AB, BC, CA, AO, BO, CO, ab, bc,

ca, ao, Bo and Co. Press the start key to move the cursor to the tap, press the select

key number to change between 0-9 (10 bits), press the start key to move the cursor to

one bit, press the select key number to change between 0-9.

When the cursor is in the winding temperature, pressing the start key can make the

cursor scroll between three data bits, and the selection key can make the data of

each data bit circulate between 0 and 9.

When the cursor is in the conversion temperature, press the select key, reduced

Summary of Contents for HZ-3110

Page 1: ...HZ 3110 Transformer DC Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...s I Introduction 1 II Safety Measure 1 III Configuration 1 IV Technical Data 2 V Presentation Of The System 2 VI Test and Operating 3 VII Caution 9 VIII Guarantee and After Sales Service 9 IX Packing...

Page 3: ...It is a test instrument of high precision simple direct way to achieve fast transformer measurement II Safety Measure 1 Before using this equipment you must carefully read the manual 2 The equipment...

Page 4: ...ment is always working at minimum power state effective energy saving reduce heat 7 320 x240 matrix of ultra small pixel 65Ktrue color LCD 8 With calendar clock and power storage can store 1000 groups...

Page 5: ...S up key press the key after selecting the current The microcomputer control to realize all testing process I I Current output terminals I is the positive current I is the negative current V V Voltage...

Page 6: ...firm meanwhile insure a well connection of the earthing wire A Single phase testing method to see the following drawing B magnetic assisted connections see picture 3 to 5 suitable Y N d 11junction gro...

Page 7: ...5 Picture 3 4 5 respectively measure low voltage Rac Rba Rcb connection 2 Instrument operation instructions 1 The boot interface displays as shown in figure 1...

Page 8: ...d when the cursor is separated press the select key and the phase can be displayed cyclically between AB BC CA AO BO CO ab bc ca ao Bo and Co Press the start key to move the cursor to the tap press th...

Page 9: ...ding temperature press the start button to start measurement 2 After selecting the current press the start button to start charging LCD display charging After a few seconds Testing is displayed indica...

Page 10: ...select key to reduce data and press the start key to increase data 5 Move the cursor to the host parameters in figure 2 then press the select key to enter the interface as shown in figure 6 Figure 6 P...

Page 11: ...he range and select the suitable current and carry testing 4 After the test press RESET and winding device will disconnect the power supply discharge alarm Ammeters back to zero then restore status an...

Reviews: