- 24 -
① In standby mode, the meter displays the pre-setting current.
② In cutting mode, the meter displays the actual cutting current, when adjust the
current, the meter will display the pre-setting current again, after adjusting, meter
displays the actual current again.
5.Secondary menu
The secondary menu set the post gas flow time and monitoring the consumables life
time
In order to avoid nozzle and electrode over use, can select monitoring alarm function.
Piercing times and cutting time over the set value, the alarm code E85 will warning or stop
Operation
:
① In standby mode, press “OPERATE” key 5 seconds, turn to secondary menu;
② Rotate the parameter adjust knob, choose secondary menu code, press cutting
mode select knob and enter parameter adjusting;
③ Rotate the parameter adjust knob, adjust the parameter value, press cutting
model selection mode to save the parameter;
④ Press “operation mode select” key 5 seconds again to quit the secondary menu.
If there is no any of operation in 30 seconds, it will quit the secondary menu
automatically.