l
If BFD session parameters are specified, the modified parameters take effect.
l
If BFD session parameters are not specified, go to
Step 3
If the fault persists, collect the following information and contact Huawei technical support
personnel.
l
Results of the preceding troubleshooting procedure.
l
Configuration files, log files, and alarm files of the devices.
----End
Relevant Alarms and Logs
Relevant Alarms
None.
Relevant Logs
None.
11.2.4 Dynamic BFD Session Fails to Be Created
Common Causes
This fault is commonly caused by one of the following:
l
BFD is not enabled for the protocol.
l
The route to the peer of the BFD session does not exist in the routing table.
l
The interface is prohibited from creating a BFD session.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
11 Reliability
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
333