l
If the
Line protocol current state
field displays
DOWN(BFD status down)
, the interface
status is set to
BFD status down
after the BFD session detects a link fault. Then, go to
l
If the
Line protocol current state
field displays
UP
but the interface cannot forward packets,
the forwarding module is faulty. See the section
forwarding fault.
Step 2
Run the
display bfd session
all
command to view the status of the BFD session.
l
If the BFD session is
Down
l
If the BFD session is
Up
, go to
.
Step 3
Run the
display current-configuration
configuration
bfd-session
command to check that the
process-interface-status
command is configured.
l
If the
process-interface-status
command is configured, the interface is set to
DOWN(BFD
status down)
because the BFD session detected a fault and went Down.
l
If the
process-interface-status
command is not configured, go to
Step 4
If the fault persists, collect the following information and contact Huawei technical support
personnel.
l
Results of the preceding troubleshooting procedure.
l
Configuration files, log files, and alarm files of the devices.
----End
Relevant Alarms and Logs
Relevant Alarms
None.
Relevant Logs
None.
11.2.3 Changed BFD Session Parameters Do Not Take Effect
Common Causes
This fault is commonly caused by the following:
l
After parameters of a BFD session have been changed, changed configurations are not
committed.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
11 Reliability
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
331