Figure 6-31 Removing the outdoor fan blades (for NetCol500-A018)

FusionModule800 Smart Small Data Center

User Manual

6 O&M

Issue 01 (2021-02-05)

Copyright © Huawei Technologies Co., Ltd.

439

Summary of Contents for V100R021C00

Page 1: ...FusionModule800 Smart Small Data Center V100R021C00 User Manual Issue 01 Date 2021 02 05 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...s document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of th...

Page 3: ...may be found in this document are defined as follows Symbol Description Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates...

Page 4: ...e and environment deterioration Change History Changes between document issues are cumulative The latest document issue contains all updates made in previous issues Issue 01 2021 02 05 This issue is the first official release FusionModule800 Smart Small Data Center User Manual About This Document Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd iii ...

Page 5: ...binet 20 3 1 2 Converged Cabinet 22 3 1 3 Components of Single Row Cold and Hot Aisle Containment 24 3 2 Power Supply and Distribution System 26 3 2 1 Technical Specifications 26 3 2 2 Working Principles 28 3 2 3 Key Hardware Devices 28 3 2 3 1 Power Distribution Module 28 3 2 3 2 6 kVA UPS 29 3 2 3 3 Battery Module 30 3 2 3 4 PDU2000 31 3 2 3 4 1 Non intelligent PDU2000 31 3 2 3 4 2 Optional Inte...

Page 6: ... 3 8 Environment Monitoring System 66 3 4 3 8 1 Optional WLDS900 Water Sensor 66 3 4 3 8 2 Optional Electrode Water Sensor 67 3 4 3 8 3 T H Sensor 67 3 4 3 8 4 Temperature Sensor 68 3 4 3 8 5 Ambient T H Sensor 69 3 4 3 8 6 Smoke Detector 70 3 4 3 9 Cabinet Electronic Clasp Lock 71 3 4 3 10 Optional Room Access Control System 73 3 4 3 10 1 Access Actuator 73 3 4 3 10 2 Fingerprint and Card Reader ...

Page 7: ...ontainments 106 4 2 3 Adjusting the Positions of Aisle Side Sealing Plates 111 4 2 4 Installing a Cabinet 114 4 2 5 Optional Installing the eLight 116 4 2 6 Installing a Smart Cooling Product 119 4 2 6 1 Materials 119 4 2 6 2 Layout Principles 124 4 2 6 3 Installing an Outdoor Unit 125 4 2 6 3 1 Installation Requirements 125 4 2 6 3 2 Space Requirements 127 4 2 6 3 3 Securing an Outdoor Unit 129 4...

Page 8: ...ay and an ETH Converter 191 4 2 9 9 Routing the Cable to a WLDS900 Water Sensor 194 4 2 9 10 Installing an Electrode Water Sensor 199 4 2 9 11 Optional Installing an In Room Access Actuator 200 4 2 9 12 Optional Installing an In Room Double Door Magnetic Lock 202 4 2 9 13 Optional Installing an In Room Single Door Magnetic Lock 205 4 2 9 14 Optional Installing an In Room Fingerprint and Card Reade...

Page 9: ...missioning 251 5 1 1 1 Checking Before Power On 251 5 1 1 2 Single UPS Operations 251 5 1 1 2 1 Starting a UPS Using Mains Power 251 5 1 1 2 2 Shutting Down a UPS 253 5 1 1 2 3 Performing EPO 253 5 1 1 3 Parallel System Operations 254 5 1 1 3 1 Starting the UPSs Using Mains Power 254 5 1 1 3 2 Shutting Down a Parallel System 255 5 1 1 3 3 Performing EPO 257 5 1 2 Connecting the Lithium Battery Sup...

Page 10: ...I 317 5 3 11 5 4 Setting Parameters on the VCN IVS Client 320 5 3 11 6 Commissioning a Network Video Recorder IVS1800 Scenario 322 5 3 11 6 1 Setting Parameters on the IVS1800 WebUI 322 5 3 11 6 2 Setting Parameters on the iClient 326 5 3 12 Linkage Control 332 5 3 12 1 Linking the Emergency Ventilation with Cabinet Electronic Clasp Lock Open 334 5 3 12 2 Link Smoke Alarm with Cabinet Electronic C...

Page 11: ...ng a PDU2000 400 6 4 2 Replacing Power Supply and Distribution System Components 401 6 4 2 1 Replacing a Surge Protection Module 401 6 4 2 2 Replacing a Fuse 403 6 4 2 3 Replacing an Indicator 403 6 4 2 4 Replacing a UPS2000 G 405 6 4 2 5 Replacing a Lithium Battery 409 6 4 2 6 Replacing the Monitoring Board from the ATS Subrack 410 6 4 2 7 Replacing an ATS Subrack 411 6 4 3 Replacing Cooling Syst...

Page 12: ...6 4 4 11 Replacing a Remote T H Sensor 33010516 471 6 4 4 12 Replacing a Temperature Sensor 472 6 4 4 13 Replacing a Smoke Sensor 473 6 4 4 14 Replacing a WLDS900 Water Sensor and Water Detection Rope 475 6 4 4 15 Replacing an Electrode Water Sensor 478 6 4 4 16 Replacing an eLight Strip Light 478 6 4 4 17 Replacing an eLight Actuator 479 6 4 4 18 Replacing an eLight Power Supply 480 6 4 4 19 Repl...

Page 13: ... warranty Follow local laws and regulations when installing operating or maintaining the equipment The safety instructions in this document are only supplements to local laws and regulations Huawei will not be liable for any consequences of the following circumstances Operation beyond the conditions specified in this document Installation or use in environments which are not specified in relevant ...

Page 14: ...for installation operation and maintenance Before handling a conductor surface or terminal measure the contact point voltage and ensure that there is no risk of electric shock After installing the equipment remove idle packing materials such as cartons foam plastics and cable ties from the equipment area In the case of a fire immediately leave the building or the equipment area and turn on the fir...

Page 15: ...tches caused during equipment transportation or installation in a timely manner Equipment with scratches cannot be exposed to an outdoor environment for a long period of time Before operations ensure that the equipment is firmly secured to the floor or other solid objects such as a wall or an installation rack Do not use water to clean electrical components inside or outside of a cabinet Do not ch...

Page 16: ...ipment Professionals personnel who are trained or experienced in equipment operations and are clear of the sources and degree of various potential hazards in equipment installation operation maintenance Trained personnel personnel who are technically trained have required experience are aware of possible hazards on themselves in certain operations and are able to take protective measures to minimi...

Page 17: ... powered facilities must be performed by qualified personnel Cabling When routing cables ensure that a distance of at least 30 mm exists between the cables and heat generating components or areas This prevents damage to the insulation layer of the cables Do not route cables behind the air intake and exhaust vents of the equipment Ensure that cables meet the VW 1 or ZB flame spread rating requireme...

Page 18: ...with ESD packaging materials before storing or transporting them Figure 1 1 Wearing an ESD wrist strap Neutral Ground Voltage It is recommended that the three phase loads be equalized and the neutral ground voltage be kept at less than 2 V to meet power distribution requirements 1 4 Installation Environment Requirements To prevent fire due to high temperature ensure that the ventilation vents or h...

Page 19: ...ng at heights Wear personal protective equipment such as the safety helmet and safety belt or waist rope and fasten it to a solid structure Do not mount it on an insecure moveable object or metal object with sharp edges Make sure that the hooks will not slide off Set a restricted area and eye catching signs for working at heights to warn away irrelevant personnel Carry the operation machinery and ...

Page 20: ...e wooden or fiberglass ladders when you need to perform live working at heights When a step ladder is used ensure that the pull ropes are secured and the ladder is held firm Before using a ladder check that it is intact and confirm its load bearing capacity Do not overload it Ensure that the ladder is securely positioned The recommended angle for a ladder against the floor is 75 degrees as shown i...

Page 21: ...ents or cables inside Metal shavings from drilling may short circuit boards inside the equipment Obtain the consent from the customer and subcontractor before drilling Wear goggles and protective gloves when drilling holes When drilling holes protect the equipment from shavings After drilling clean up any shavings that have accumulated inside or outside the equipment Moving Heavy Objects DANGER Wh...

Page 22: ... Cooling System Safety Welding At least two persons are required on a welding site A welder must have a work permit A welding site must be free from inflammables Ensure that a fire extinguisher wet wiper and water container are available A burning welding torch must not be placed on a component or on the floor and must not be placed in a metal container with acetylene and oxygen Otherwise the gas ...

Page 23: ...recautions for battery handling and master the correct battery connection methods DANGER Do not expose batteries at high temperatures or around heat generating devices such as sunlight fire sources transformers and heaters Excessive heat exposure may cause the batteries to explode Do not burn batteries Otherwise the batteries may explode To avoid leakage overheating fire or explosions do not disas...

Page 24: ...rared radiation organic solvents and corrosive gases Take fire prevention measures Place and secure batteries horizontally Note the polarities when installing batteries Do not short circuit the positive and negative poles of the same battery or battery string Otherwise the battery may be short circuited Check battery connections periodically ensuring that all bolts are securely tightened When inst...

Page 25: ...ery The safety precautions for lithium batteries are similar to those for lead acid batteries except that you also need to note the precautions described in this section WARNING There is a risk of explosion if a battery is replaced with an incorrect model A battery can be replaced only with a battery of the same or similar model recommended by the manufacturer When handling a lithium battery do no...

Page 26: ...00 Doing so may affect the power supply to equipment which will interrupt services Exercise caution when manually shutting down the UPS inverter for transferring to bypass mode or when adjusting the UPS output voltage level or frequency Doing so may affect the power supply to equipment Exercise caution when setting battery parameters Incorrect settings will affect the power supply and battery life...

Page 27: ...nd county level data centers of the government vertical industry small sized second level branches and large sized offices in the financial industry and equipment rooms of small and medium sized enterprises The following figure shows the position of the FusionModule800 in the product family FusionModule800 Smart Small Data Center User Manual 2 Product Description Issue 01 2021 02 05 Copyright Huaw...

Page 28: ...le800 in the financial industry 1 FusionModule5000 2 FusionModule2000 3 FusionModule800 4 FusionModule500 FusionModule800 Smart Small Data Center User Manual 2 Product Description Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 16 ...

Page 29: ... cables are separately routed to minimize the electromagnetic interference The UPS is configured with a manual maintenance bypass switch When the equipment is working properly the switch is locked to prevent electrical accidents caused by misoperations If the cooling system is faulty due to problems such as a power failure the equipment room environment is used to facilitate heat dissipation In th...

Page 30: ...products facilitate flexible expansion Fast and Flexible Deployment The integrated design supports the relocation of equipment with offices Flexible deployment based on the dimensions of the equipment room and the power consumption of each cabinet is supported to meet the requirements of capacity expansion IT cabinets are flexibly configured with servers and storage and network devices to meet ent...

Page 31: ...ium sized enterprises and branches of large companies Target markets Asia Pacific Africa including high temperature areas in North Africa Europe and Middle East 380 415 V 3Ph N 50 60 Hz power systems are supported FusionModule800 Smart Small Data Center User Manual 2 Product Description Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 19 ...

Page 32: ...amework 3 Gas spring 4 Side sealing plate 5 Cabinet electronic clasp lock 6 Converged Cabinet 3 1 1 Cabinet Cabinets are classified into the Converged Cabinet IT cabinet and network cabinet FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 20 ...

Page 33: ... kg Converged Cabinet 410 kg Color Black Material High intensity class A carbon cold rolled steel plate and zinc coated steel plate Ventilation channel Front and rear ventilation channels Space for installing the IT cabinet and network cabinet Each cabinet provides 42 U available space the position of each U is marked on the vertical mounting bars The maximum depth for installing devices inside th...

Page 34: ...ing Hole L x W IT cabinet 980 mm x 400 mm Network cabinet 980 mm x 600 mm 3 1 2 Converged Cabinet The Converged Cabinet consists of the indicator module rack mounted UPS module input and output power distribution module monitoring module smart cooling product control unit and rack mounted smart cooling product FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 ...

Page 35: ...Figure 3 4 Converged Cabinet FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 23 ...

Page 36: ...le Row Cold and Hot Aisle Containment The components of single row aisle containment include an enclosed framework door components and binding plates or M shaped cable troughs Single row cold and hot aisle containment Figure 3 6 Layout of single row cold and hot aisle containment FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technolo...

Page 37: ... dedicated keys Figure 3 7 Front door Figure 3 8 Rear door Cable Trough Optional Cable troughs are clamped one by one to form a whole A cable trough is assembled by clamping two side panels one pallet and one baffle used to separate ELV optical fiber cables from ELV network cables and electrical route A from electrical route B FusionModule800 Smart Small Data Center User Manual 3 System Architectu...

Page 38: ...ooling products The N architecture of the UPS system is supported IT power distribution supports a maximum of four cabinets The air cooled smart cooling product consists of the indoor unit and outdoor unit and is supplied with mains power The management system consists of the ECC800 Pro VCN IVS1800 optional camera optional cabinet electronic clasp lock temperature sensor temperature and humidity s...

Page 39: ...ingle power input Supported UPS selection UPS2000 G 6 kVA Power supply and distribution mode Normal temperature N Power system 380 V 400 V 415 V 50 60 Hz 3 Ph N PE PDU2000 Input voltage range 187 V AC 264 V AC 1 Ph Maximum input current 32 A FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 27 ...

Page 40: ...bution Module Table 3 4 Power distribution module specifications Item Specifications System parameters Single input IT load power 8 5 kW two 6 kVA UPSs one smart cooling product front operation front and rear maintenance Dimensions H x W x D 130 5mm 442mm 450mm FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 28 ...

Page 41: ...x subrack 6 C125A 2P MCB 3 2 3 2 6 kVA UPS The UPS2000 G 6KRTLL is an online transformerless UPS It consists of main power circuits such as EMI and PFC INV and the monitoring unit The UPS supports 48 V lithium battery input and multiple UPSs can be connected in parallel T he UPS provides USB RS232 and RS485 ports Figure 3 11 Front and rear views of a 6 kVA UPS FusionModule800 Smart Small Data Cent...

Page 42: ...t guide and Modbus user manual a The USB port supports the standard Modbus protocol and can be connected to the NetEco through a USB cable 3 2 3 3 Battery Module The UPS uses 48 V lithium battery modules to provide backup power Only the ESM 48100B1 and ESM 48150B1D are applicable to the 6 kVA UPS The 100 Ah and 150 Ah battery modules have the same panels and ports but different dimensions Figure 3...

Page 43: ... 3 2 3 4 PDU2000 3 2 3 4 1 Non intelligent PDU2000 By default IEC sockets are configured for all PDU2000s GB sockets are optional Figure 3 13 Full height PDU2000 NOTE Figures provided in this document are for reference only Table 3 6 PDU2000 specifications Type Model Output Port IEC PDU2000 32 1PH 20 4 B9 full height 20 x C13 4 x C19 GB PDU2000 32 1PH 20 4 B2 full height 20 10A 4 16A FusionModule8...

Page 44: ...he communication status normal or abnormal of the monitoring board Remotely set the input overcurrent warning threshold overvoltage alarm threshold and undervoltage alarm threshold through a serial port or locally set these parameters Working status indicator The PDU has a built in input status indicator which indicates the working status of the PDU Input alarm If any of input overcurrent overvolt...

Page 45: ...ectric energy 3 2 3 5 ATS Subrack Figure 3 15 ATS subrack 1 Dual input indicator 2 Monitoring board 3 Route II switch button 4 Route I II status display window 5 Handle FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 33 ...

Page 46: ...g or minor alarm Steady red major or critical alarm 2 AUTO ATS working mode indicator Steady green automatic control mode Steady red manual mode or non firefighting power disconnection 3 I Route I power status indicator Steady green normal Steady red abnormal FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 34 ...

Page 47: ...uct meet the environmental protection requirements The environmental protection mark is as follows Figure 3 17 Environmental protection mark Table 3 9 Indoor unit technical specifications Item NetCol5000 A013HX0E1 Excluding Heater and Humidifier Power system 208 V AC 240 V AC 50 Hz 60 Hz 1 Ph N PE 2 Ph PE Voltage tolerance If upstream voltage fluctuation exceeds the rated voltage 10 you are advise...

Page 48: ... H x W x D b 486mm 442mm 800mm Package dimensions H x W x D 710mm 610mm 1000mm Net weight Gross weightb 49 4kg 66 8kg IP rating IP20 a The cooling capacity of the smart cooling product is obtained when the indoor dry bulb temperature is 37 8 C the indoor wet bulb temperature is 20 8 C and the outdoor dry bulb temperature is 35 C The actual cooling capacity varies depending on the indoor and outdoo...

Page 49: ... type Class B Class B Class B Protection level IPX4 IPX4 IPX4 Outdoor unit application environments are classified by severity as follows Class A controlled environment indoor environments where the ambient temperature and humidity are controlled including rooms where people live Class B uncontrollable environment indoor environments where the ambient temperature and humidity are not controlled or...

Page 50: ... smart cooling product is derated when the altitude ranges from 1000 m to 4000 m The maximum outdoor operating temperature decreases 1 C and the nominal cooling capacity decreases by 1 for each additional 200 m Installation Requirements Table 3 12 Installation requirements Installation Mode Rack mounted Vertical Difference Between the Indoor and Outdoor Units Outdoor unit placed higher than the in...

Page 51: ...rainpipe connectors with external threads are provided in standard configuration Drainpipes and BSPP 1 2 inch connectors with internal threads should be prepared by the customer Ports Table 3 13 Ports Item Specifications Refrigerant gas pipe L 60 m reserved port 5 8 inch 15 9 mm thread connection 60 m L 80 m reserved port 7 8 inch 22 2 mm thread connection Refrigerant liquid pipe L 60 m reserved p...

Page 52: ...r unit 3 3 3 2 Outdoor Unit The outdoor unit consists of the DC variable frequency compressor oil separator gas liquid separator filter dryer fan and refrigerant pump only for the low temperature outdoor unit Figure 3 19 Exterior of the outdoor unit of a normal temperature model FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technolog...

Page 53: ... high temperature model Figure 3 21 Exterior of the outdoor unit of a low temperature model 3 4 Monitoring System FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 41 ...

Page 54: ...smart module Figure 3 22 Management system network diagram Table 3 14 Network diagram description Device Maximum Quantity Port Camera 3 FE VCN IVS1800 1 FE Smart ETH gateway 8 FE Access actuator 2 One access actuator connects to at most one magnetic lock one access control device one exit button and one emergency door release button FE NetCol5000 A013 smart cooling product 4 FE UPS2000 4 RS485 Smo...

Page 55: ... Access control equipment A standard room level access management system is integrated to manage and monitor key information such as door status card swiping and permission setting Figure 3 23 Layout of the access control system NOTE The access actuator should be installed near the door have a maximum of 3 5 m cabling distance away from the magnetic lock and have a maximum of 5 m cabling distance ...

Page 56: ...e and humidity on the floor plan Facial recognition is supported through an app installed on a tablet computer After facial recognition information is added click Facial Enter to start the facial recognition If you do not have facial recognition permission or an error occurs during facial recognition you can use the user name and password login manner After logging in to the app installed on the t...

Page 57: ...module when a smoke alarm is generated the door of the linked cabinet is not opened If the door is opened an alarm door status alarm is generated If the protected area of the fire extinguishing system is outside the smart module when a smoke alarm is generated key hardware devices on the rear door of the linked cabinet are opened 3 4 3 Key Hardware Devices 3 4 3 1 ECC800 Pro 3 4 3 1 1 Product Conf...

Page 58: ... control module Color Black Installation requirements Can be installed in a 1 U space in a standard 19 inch cabinet Environmental protection RoHS5 REACH WEEE Figure 3 25 ECC800 Pro rear view 1 53 5V DC_OUT1 2 53 5V DC_OUT2 3 AC_INPUT1 4 AC_INPUT2 Power Port The ECC800 Pro provides four power ports including two AC input ports AC_INPUT1 and AC_INPUT2 and two DC output ports DC_OUTPUT1 and DC_OUTPUT...

Page 59: ... indicator 3 AIDI_1 4 AIDI_2 5 COM1 AIDI_4 6 COM3 12V 7 WAN1 8 LAN1 POE 9 LAN2 POE 10 WAN2 11 COM4 CAN 12 COM2 AIDI_5 13 AIDI_3 14 DO 12V 15 RF_Z 802 15 4 16 WLAN reserved 17 4G 18 SW button NOTE The WLAN port is reserved and cannot be connected to a WLAN antenna for WLAN communication FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Te...

Page 60: ...stem and WAN2 is used for maintenance The ports support autonegotiation of 10 100 1000 Mbit s communication rates Connect shielded network cables to the WAN ports LAN port Supports two LAN ports which can be connected to the LAN The ports support autonegotiation of 10 100 1000 Mbit s communication rates Connect shielded network cables to the LAN ports RS485 serial port expansion Output voltage 13 ...

Page 61: ...IDI_4 and COM3 12V ports Group 3 12 V of the AIDI_3 and COM2 AIDI_5 ports Wireless communicatio n Supports wireless communication that complies with IEEE802 15 4 4G Supports the 4G module SMS sending and 3G communication and provides a standard SIM card slot 1 China 2G and 4G networks support China Unicom or China Mobile SIM cards and 3G networks support only China Unicom SIM cards 2 Outside China...

Page 62: ...ports RF_Z 802 15 4 networking Table 3 19 ECC800 Pro RF_Z parameters Item Specifications RF_Z operating frequency 2405 2480 MHz RF_Z EIRP max 8 dBm Table 3 20 ECC800 Pro 4G parameters Item Specifications Operating frequency 4G LTE FDD covering frequency bands B1 B3 B5 B7 B8 and B20 LTE TDD covering frequency bands B38 B40 and B41 3G WCDMA covering frequency bands B1 B5 and B8 2G GSM covering frequ...

Page 63: ...n4 GE3 Pin5 GE3 Pin6 GE2 Pin7 GE4 Pin8 GE4 Indicator Green indicator Linked steady on Yellow indicator ACT data communication blinking Table 3 22 COM1 AIDI_4 COM2 AIDI_5 port pin definitions Item Description Pin sequence Pin1 RS485 Pin2 RS485 Pin3 12V DC_OUT Pin4 RS485 Pin5 RS485 Pin6 DI FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei ...

Page 64: ... 12V DC_OUT Pin4 RS485 Pin5 RS485 Pin6 Pin7 Pin8 GND Indicator Green indicator Power output indicator Steady on The 12 V DC output is normal Off No 12 V DC output is provided Table 3 24 COM4 CAN port pin definitions Item Description Pin sequence Pin1 RS485 Pin2 RS485 Pin3 Pin4 RS485 Pin5 RS485 Pin6 Pin7 CAN_H Pin8 CAN_L FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issu...

Page 65: ... Table 3 25 AIDI_1 AIDI_2 and AIDI_3 ports pin definitions Item Description Pin sequence Pin1 Type_1 Pin2 Type_2 Pin3 12V DC Pin4 Type_3 Pin5 Type_4 Pin6 DI Pin7 DI Pin8 GND Indicator Green indicator Power output indicator Steady on The 12 V DC output is normal Off No 12 V DC output is provided Table 3 26 DO 12V port pin definitions Item Description Pin sequence Pin1 Pin2 Pin3 12V DC_OUT Pin4 Pin5...

Page 66: ...s normal the program is being loaded Off The power supply is abnormal Blinking at long intervals The software runs properly the indicator blinks at 0 5 Hz on for 1s and then off for 1s or the ECC800 Pro registers with the NetEco successfully Blinking at short intervals The ECC800 Pro does not register with the NetEco the indicator blinks at 5 Hz on for 0 125s and then off for 0 125s ALM Red Alarm ...

Page 67: ...s to 5s to enter the wireless network pairing mode The RF_Z indicator is blinking at super short intervals In wireless network 802 15 4 pairing mode press and hold down the button for 3s to 5s to exit the pairing mode or the system automatically exits the pairing mode after 30 minutes without pressing the button The RF_Z indicator is blinking at long intervals Press and hold down the button for mo...

Page 68: ...nerates a forewarning indicating that power will be limited due to ambient overtemperature or generates a protection shutdown alarm due to ambient overtemperature or undertemperature Power input overvoltage or undervoltage protection Reverse DC input connection Slight current imbalance Output overvoltage Hibernation Off The converter generates no protection alarms Blinking at long intervals The co...

Page 69: ...ability Remote management You can monitor manage and upgrade one or more smart cooling products using the remote management function provided by Huawei Configuration synchronization You can synchronize parameters between smart cooling products on the touchscreen optional of the Converged Cabinet ECC800 Pro WebUI or ECC800 Pro app One click export You can export the alarms and logs of a smart cooli...

Page 70: ...s in real time over the app The recommended model is T5 10 Figure 3 29 PAD Table 3 31 PAD structural specifications Item Specifications Dimensions L x W x H 243 mm x 164 mm x 7 8 mm Weight About 460 g Table 3 32 PAD technical specifications Item Specifications Touchscreen 10 1 inch 1920 x 1200 resolution IPS screen and multi touch Storage Machine 32 GB Memory 3 GB Extension card Micro SD a maximum...

Page 71: ...or 4980 mAh rated value WiFi connection web page browse time about 6 5 hours Power adapter charge time about 3 5 hours 5 V 2 A adapter 3 4 3 4 WiFi Module The WiFi module provides WiFi signals for equipment such as pads and mobile phones to interact with the host computer Figure 3 30 WiFi module Table 3 33 Technical specifications Item Specifications Wireless standard IEEE 802 11n IEEE 802 11g and...

Page 72: ...sing Storage humidity 5 90 RH non condensing Power 0 8 W 3 4 3 5 ETH Converter The ETH converter is used to convert the Modbus RTU protocol or CAN protocol to the Modbus MAC protocol for connecting to the PoE bus Figure 3 31 ETH converter 1 Status indicator 2 BLINK button 3 COM1 communications port 4 COM2 communications port 5 48 V power port 6 PoE port FusionModule800 Smart Small Data Center User...

Page 73: ...hen off for 0 5s for 10 seconds E label Supported Indicators Table 3 35 ETH converter indicators Indicat or Color Name Status Description PWR Green Power input status indicator Steady on The power input is normal Off There is no power input RUN Green Operating status indicator Off The power supply is abnormal Blinking at long intervals The ETH converter successfully registers with the ECC800 Pro a...

Page 74: ...gateway allows the extension of the 53 5 V DC power supply and FE communication for the ECC800 Pro and can be flexibly deployed in a smart module Figure 3 32 Smart ETH gateway 1 PWR_IN cascading power port 2 FE_1 cascading signal port 3 POE_1 2 ports 4 POE_3 4 ports 5 48V_OUT1 power output port 6 48V_OUT2 power output port 7 FE_2 cascading signal port 8 PWR_OUT cascading power port 9 BLINK button ...

Page 75: ...minal with an indicator 10 100M communications rate complying with IEEE802 3 IEEE802 3u IEEE802 3af at BLINK button If you press the BLINK button the RUN indicator blinks intermittently at super short intervals blinking at super short intervals for 0 5s and then off for 0 5s for 5 seconds Indicators Table 3 37 Indicators on a smart ETH gateway Indica tor Color Name Status Description PWR Green Pow...

Page 76: ... current is overloaded Off The PoE output is normal or not connected 3 4 3 7 Optional eLight The eLight system consists of the eLight power system eLight actuator eLight strip light and cables Figure 3 33 eLight strip light Figure 3 34 eLight actuator NOTE The appearance of the eLight actuator depends on the actual delivery FusionModule800 Smart Small Data Center User Manual 3 System Architecture ...

Page 77: ...lor indicates only the highest alarm severity eLight fault The eLight disconnects from the ECC800 Pro and blinks in red Table 3 39 eLight technical specifications Item Specifications eLight power supply Rated input voltage 220 230 240 V AC Frequency 50 60 Hz Output 93 W 24 V DC Certification CE eLight actuator Rated input voltage 24 V DC Two output channels The I output is connected to the RGBW fl...

Page 78: ...umidity range 5 95 non condensing 3 4 3 8 Environment Monitoring System 3 4 3 8 1 Optional WLDS900 Water Sensor The WLDS900 water sensor with the BOM number of 33010352 consists of a water detection cable a water detector and a conversion cable Figure 3 35 WLDS900 water sensor Table 3 40 Technical specifications of the WLDS900 water sensor Item Specification Operating voltage 12 V DC 9 16 V DC Ope...

Page 79: ...s electrode probes and cables Figure 3 36 Electrode water sensor Table 3 41 Technical specifications of the electrode water sensor Item Specification Operating temperature 40 C to 80 C Storage temperature 40 C to 80 C Service life 10 years 3 4 3 8 3 T H Sensor FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 67 ...

Page 80: ...o connect to six NTC temperature sensors each RJ45 port connecting to three NTC temperature sensors Signal port RS485 Power supply 5 16 V DC typical value 12 V DC Power consumption 280 mW Storage environment 40 C to 70 C Weight About 85 g 3 4 3 8 4 Temperature Sensor The temperature sensor BOM number 33010348 is used for surface temperature measurement industrial process control and measurement in...

Page 81: ...10ºC to 55ºC Operating voltage 10 16 V DC Storage temperature 40ºC to 70ºC 3 4 3 8 5 Ambient T H Sensor Figure 3 39 Appearance The T H sensor BOM number 33010516 uses an RJ45 port NOTE The appearance of the T H sensor depends on the onsite delivery FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 69 ...

Page 82: ...ange 20 C to 80 C Temperature accuracy 0 5 C 25 C 1 C full measuring range Operating temperature 20 C to 80 C Operating voltage 9 16 V DC Storage temperature 40 C to 80 C Output Two RJ45 ports bidirectional cascading 3 4 3 8 6 Smoke Detector A smoke detector detects smoke around cabinets FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei ...

Page 83: ...tor is steady on Operating temperature 10 C to 55 C Ambient humidity 95 RH Dimensions H x W x D 31 mm x 75 mm x 51 mm with the base Weight 50 g 3 4 3 9 Cabinet Electronic Clasp Lock The cabinet electronic clasp lock is used to manage access control It can be automatically unlocked or manually locked and unlocked FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 202...

Page 84: ...le 3 47 RJ45 port definitions No Pin Description Description 1 RS485 RS485 2 RS485 RS485 3 12 V power supply 12VDC 4 RS485 RS485 5 RS485 RS485 6 7 8 Ground GND FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 72 ...

Page 85: ... intervals blinking at 10 Hz on for 0 05s and then off for 0 05s The cycle lasts for 5s ALM Red Alarm indicator Stead y on A system failure alarm is generated Off The system is normal 3 4 3 10 Optional Room Access Control System 3 4 3 10 1 Access Actuator The access actuator is the control component for the aisle door in a smart module It connects to the ECC800 Pro controller over FE and wireless ...

Page 86: ...ltage of 36 60 V DC POE input One POE port that complies with IEEE802 3at POE port FE communication 10 100M communications rate Wireless communicat ion One wireless communication port that complies with IEEE802 15 4 mutual backup with FE communication AI DI port Two AI DI ports can connect to the fire alarm and exit button DO DI port One 12 V DC power output that controls magnetic locks terminal O...

Page 87: ...rch for a network and start networking Hold down the button for more than 10 seconds to clear network parameters Address DIP switch 4 pin address DIP switch E label Supported Indicators Table 3 50 Access actuator indicator description Indicator Color Name Status PWR Green Power input status indicator Steady on The power input is normal Off There is no power input FusionModule800 Smart Small Data C...

Page 88: ...nication fails or the access actuator fails to register with the ECC800 Pro the indicator blinks at 4 Hz on for 0 125s and then off for 0 125s Blinking The indicator blinks at super short intervals for 0 5s blinking at 10 Hz on for 0 05s and then off for 0 05s and then turns off for 0 5s The cycle lasts for 5s ALM Red Alarm indicator Steady on A system failure alarm is generated Off No system alar...

Page 89: ...n off for 0 05s Blinking intermittently at super short intervals The access actuator is searching for a network the indicator blinks at super short intervals for 0 5s and then turns off for 0 5s Communications Ports The access actuator provides one DO port LOCK GND and one DI port GATE COM Table 3 51 lists the LOCK GND GATE COM port pin definitions Table 3 51 LOCK GND GATE COM port pin definitions...

Page 90: ...d reader with a keypad Item Specifications Dimensions L x W x H 156 mm x 53 mm x 38 mm Rated operating voltage 12 V DC 15 Rated operating current 300 mA 15 Card type supported IC card Authorized storage A maximum of 3000 authorized users with a maximum of 6000 fingerprints Communications mode RS485 and Wiegand communications ports FusionModule800 Smart Small Data Center User Manual 3 System Archit...

Page 91: ...hree Authorized fingerprint collection LED indicator The indicator blinks blue red and blue in order Fingerprint reader The indicator turns on white Buzzer sounds The buzzer sounds once Card swiping LED indicator The indicator blinks blue red and blue in order Buzzer sounds The buzzer sounds once 3 4 3 10 3 Fingerprint and Card Reader Figure 3 45 Fingerprint and card reader 1 Fingerprint reader 2 ...

Page 92: ...der The indicator is off Unauthorized fingerprint collection LED indicator The indicator blinks blue red blue red and blue in order Fingerprint reader The indicator turns on white Buzzer sounds The buzzer sounds three Authorized fingerprint collection LED indicator The indicator blinks blue red and blue in order Fingerprint reader The indicator turns on white Buzzer sounds The buzzer sounds once C...

Page 93: ...13 2 V DC rated voltage 12 V DC Operating current Static standby current 80 mA dynamic operating current card swiping key pressing 150 mA minimum input current 12 V DC 300 mA Communication mode Wiegand communications port 3 4 3 10 5 Magnetic Lock Figure 3 47 Double door magnetic lock FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 2021 02 05 Copyright Huawei Tech...

Page 94: ...n be ceiling mounted Figure 3 49 C3220 camera Table 3 57 C3220 camera technical specifications Item Specifications Image sensor 1 2 7 two megapixel progressive scan CMOS Minimum illumination Color 0 002 lux F1 2 AGC ON 1 30s shutter speed Black White 0 0005 lux F1 2 AGC ON 1 30s shutter speed 0 lux infrared illuminator enabled Wide dynamic range 120 dB Focal length 2 8 12 mm FusionModule800 Smart ...

Page 95: ...ss bandwidth Up to 160 Mbit s access bandwidth with intelligent services enabled Video transfer 16 channel 1080p up to 160 Mbit s forwarding bandwidth 64 channel 1080p up to 320 Mbit s forwarding bandwidth Up to 160 Mbit s forwarding bandwidth with intelligent services enabled Playbac k Downlo ad 16 channel 1080p up to 80 Mbit s playback bandwidth 32 channel 1080p up to 160 Mbit s playback bandwid...

Page 96: ...orts Three USB ports two USB 2 0 ports on the front panel and one USB 3 0 port on the rear panel Audio input 1 channel RCA port Audio output 1 channel RCA port Alarm port 4 channel alarm input 2 channel alarm output Other specificatio ns Power consumpti on 8 hard disks included 124 W Power supply 110 220 V AC Weight hard disks excluded 6 60 kg Dimensions H x W x D 86 mm x 442 mm x 467 mm 3 4 3 11 ...

Page 97: ...h Ingress and egress bandwidth The ingress bandwidth does not exceed 128 Mbit s The egress bandwidth does not exceed 256 Mbit s Table 3 61 Hardware specifications Item Specifications Number of disks 2 Whether the hard disk supports hot swap No Supported hard disk type 3 TB 4 TB 6 TB or 8 TB SATA disks CPU type and maximum number of supported CPUs 1 x ARM Cortex A17 Quad core Max 1 4 GHz Memory cap...

Page 98: ...ased on requirements The system mainly monitors following devices Power equipment smart cooling product Power distribution module UPS and so on Environment equipment water sensor temperature and humidity sensor and so on Video equipment camera and so on Access control equipment A standard access management system is integrated to manage and monitor key information such as door status card swiping ...

Page 99: ...100 1000BASE T Ethernet ports four 10GE SFP ports S5731 H24P4XC Twenty four 10 100 1000BASE T Ethernet ports four 10GE SFP ports 3 4 5 Optional Edge Data Center Management System The edge data center management system monitors the running status of the entire network on the GIS home page After an abnormal site is detected you can double click it to access the site monitoring page Environment energ...

Page 100: ...ng Solution Equipotential Grounding for Cabinets in the Module A general ground bar is configured in the Converged Cabinet The ground terminals in other cabinets are connected to the general ground bar by cables with a cross sectional area no less than 16 mm2 The general ground bar is connected to the floor ground bar FEB or collective ground bar 25 mm x 3 mm copper bar laid along cable trays or w...

Page 101: ... grounding The ground bar does not have to be insulated The ground terminal should be greater than or equal to M8 A yellow ground label such as is attached close to the main ground terminal for cabinets Connect equipotential cables to metal components without carrying currents in the module such as metal doors and windows cable trays and ESD floor supports Each equipotential cable has a minimum cr...

Page 102: ... lithium batteries as well as the signal cables for the smart cooling product water sensor T H sensor smoke detector video and intelligent spring lock 3 7 Fire Extinguishing System Huawei provides only sensors for the fire extinguishing system in the smart module Other components need to be prepared by the customer FusionModule800 Smart Small Data Center User Manual 3 System Architecture Issue 01 ...

Page 103: ...ects exist If necessary clean the terminals and tighten the bolts If the battery bolts are loosely connected the voltage drop may be too high or the battery may be burnt when the current is large Table 4 1 General tools and instruments Name Specifications and Appearance Protective gloves Marker Measuring tape 5 m Level Step ladder 2 m Phillips screwdriver M4 M6 and M8 Flat head screwdriver 2 5 mm ...

Page 104: ...ool Utility knife Needle nose pliers Diagonal pliers RJ45 crimping tool Insulation tape Wire stripper Hydraulic pliers Wire clippers Crimping tool Power cable cutter Power cable crimping tool Clamp meter Multimeter FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 92 ...

Page 105: ...ts for installing smart cooling products Name Specifications and Appearance Flashlight Hacksaw Pallet truck Electronic balance Antifreeze gloves Cutter Welding torch 5 silver welding rod Oxygen Acetylene Hot melt device Clamp meter FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 93 ...

Page 106: ...nge must be at least 4 0 MPa d Vacuum pump airflow 2 4 L s absolute vacuum 60 Pa e For equipment with humidifiers ensure that the water pipe thread sealant can resist temperatures higher than 85 C and the following requirements are met Applicable to all pipe materials Anaerobic metal pipe thread sealant with PTEF as the padding Maximum gap 0 5 mm Pressure resistance above 1 6 MPa Compliant with th...

Page 107: ...Bearing capacity Standard live load of the computer room 8 12 kN m2 Suspended load of the main equipment room 1 2 kN m2 Standard live load of the battery room 16 kN m2 Passed Failed Levelness Allowed deviation 3 2000 mm Passed Failed Equipment room height 2 6m Passed Failed Equipment room area 8 30 m2 Passed Failed Door size Height 2 2 m width 0 9 m Passed Failed Elevator Elevator bearing capacity...

Page 108: ... water to the humidifier Passed Failed NOTE If any of the requirements is not met contact Huawei technical support NOTICE The UPS can generate large leakage currents A circuit breaker equipped with an RCD is not recommended If leakage protection is required select a recommended upstream circuit breaker for the smart module Table 4 4 Recommended circuit breaker NetCol500 Load Recommende d Cable and...

Page 109: ...ct Huawei technical support Figure 4 1 Site space requirements 4 1 5 Installation Scenarios NOTE The component layout illustrates only the positions of components The actual component installation positions prevail Different quantities of batteries can be installed in the Converged Cabinet depending on configurations Figure 4 2 shows the recommended layout FusionModule800 Smart Small Data Center U...

Page 110: ... 2 and 3 refer to the cabinet number and A and B refer to the PDU2000 number You are advised to number cabinets from left to right The Converged Cabinet does not have to be numbered PDU2000s are deployed at the cabinet rear door and are recommended to be numbered from exterior to interior FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei ...

Page 111: ...gure 4 5 and Figure 4 6 show the dimensions of NetCol500 A018 NetCol500 A020 and NetCol500 A021 NOTE NetCol500 A018 NetCol500 A020 and NetCol500 A021 are installed in the same way This manual uses figures of NetCol500 A018 as examples Figure 4 4 Installation dimensions of NetCol500 A018 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Te...

Page 112: ...MPa 145 psi 1 MPa 10 2 kgf cm2 4 2 Hardware Installation The angle of door opening by the gas spring is 110 Ensure that the door opening angle is less than 110 4 2 1 Transportation and Unpacking FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 100 ...

Page 113: ...tire module is installed Procedure Step 1 Use a pallet truck to transport the cabinet to the installation position Step 2 Check that the cabinet package is intact Step 3 Cut off and remove the binding straps and remove the packing Step 4 Remove the pallet from a common cabinet IT cabinet and network cabinet 1 Remove the plastic bag and take out the fitting box 2 Check the cabinet exterior for dama...

Page 114: ...sliders NOTE Obtain the paper documents about the UPS from the fitting box 2 After checking that the Converged Cabinet is intact remove the L shaped brackets that secure the cabinet to the pallet a Open the front and rear doors of the cabinet and remove the cabinet lower sealing plates b Remove the L shaped brackets c Reinstall the cabinet lower sealing plates and close the front and rear doors of...

Page 115: ...abinet lower sealing plates 3 Connect the ramps to the rear door side of the pallet and extend the ramps and then clamp the sliders at the bottom of the ramps as shown in Figure 4 11 Optional FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 103 ...

Page 116: ...re 4 12 Figure 4 12 Overtemperature mark If none of the three marks turn black the transportation meets requirements and the outdoor unit can be installed after its package is removed as instructed in Unpacking the Outdoor Unit If the mark with 60 turns black unpack the outdoor unit and open its top cover front panel and left front panel Then check whether there is trace of liquid around the safet...

Page 117: ...inst the packing list If some fittings are missing or do not comply with the packing list record the information and contact your local Huawei office immediately Step 4 After checking that the outdoor unit is intact remove the four bolts that secure the outdoor unit to the pallet as shown in Figure 4 13 Figure 4 13 Removing an outdoor unit Step 5 If necessary hoist the outdoor unit according to Fi...

Page 118: ...ported to the destination place and unpacked Context If the site elevator is too small to transport a cabinet remove the aisle containment from the cabinet Reassemble them after transporting them to the installation position Then perform subsequent operations FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 106 ...

Page 119: ...onal Cut off the cable tie on the PAD cable in the Converged Cabinet and pull the cable into the cabinet through the front door NOTICE Record the PAD cable route because you need to bind the PAD cable along the original route in subsequent installation Figure 4 17 Removing the PAD cable Step 3 Loosen the gas spring nuts using an adjustable wrench and remove the gas springs FusionModule800 Smart Sm...

Page 120: ... is heavy Arrange at least two persons to carry the door Before removing a cabinet door disconnect the ground cable between the cabinet door and the cabinet Figure 4 19 Removing the cabinet doors Step 6 Remove the top plate from the cabinet using a Phillips screwdriver FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd ...

Page 121: ...air director Figure 4 21 Removing the air director Step 8 Remove the screws securing the aisle containment to the cabinet using a Phillips screwdriver and remove the aisle containment from the cabinet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 109 ...

Page 122: ...e the removed components with the cabinets by referring to Step 8 Step 2 NOTICE During the process of reinstalling an air director when pushing the air director into the aisle containment align the positioning poles shown by 1 in Figure 4 23 at the bottom of the left and right sides of the air director with the positioning holes in the aisle FusionModule800 Smart Small Data Center User Manual 4 In...

Page 123: ...net An IT cabinet is not configured with aisle side sealing plates before delivery If you need to place the IT cabinet at an end of the row install aisle side sealing plates on the cabinet side facing the aisle exterior Totally there are six aisle side sealing plates to be removed from the Converged Cabinet Each end cabinet needs to be installed with three aisle side sealing plates Procedure Step ...

Page 124: ...NOTICE The sealing plate fasteners are packed in the accessory package of the Converged Cabinet Align the sealing plate fasteners with those in front of the appropriate sealing frame Install other aisle sealing plate fasteners in the same way Figure 4 25 Installing sealing plate fasteners for an end cabinet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 0...

Page 125: ...l aisle side sealing plates on the end cabinet side facing the aisle exterior using the screws removed in Step 1 Figure 4 27 Installing aisle side sealing plates for an end cabinet Step 6 Install aisle side sealing plates on the aisle exterior side of the other end cabinet in the same way End FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Hua...

Page 126: ...inet cannot be opened or closed properly NOTE To ensure the cabinet steadiness adjust all the six anchor bolts at the bottom of the cabinet in place After leveling the anchor bolts in the first and last rows use a flat head screwdriver to level the anchor bolts in the middle row until they are in close contact with the ground Do not remove the anchor bolts Otherwise rework is required if the cabin...

Page 127: ...ting kits of the Converged Cabinet are bound to the upper right positions on the front and rear door posts of the cabinet Remove the connecting kits before installing them The connecting kits of other cabinets are secured to the front door posts of the cabinets Remove the connecting kits before installing them Figure 4 29 Combining cabinets FusionModule800 Smart Small Data Center User Manual 4 Ins...

Page 128: ...ons Tools Phillips screwdriver step ladder Materials eLight and its accessories The BOM number of the eLight system is 52220928 Procedure Step 1 Install the strip light NOTE If the strip light is longer than the aisle cut the strip light to an appropriate length remove the protective cap from the end of the strip light and install the cap at the cutting position of the strip light 1 Reserve the en...

Page 129: ...Pull the strip light and extension cable straight and interconnect the terminals Figure 4 31 Installing a strip light NOTE The figure is for reference only The eLight strip light can be installed only for a maximum of nine cabinets Step 3 Install the eLight actuator and power module 1 Open the rear door of the end cabinet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Iss...

Page 130: ...f the top panel as shown by 2 in Figure 4 32 Figure 4 32 Install a mounting support for the eLight actuator and power module 4 Clamp the eLight actuator and power module onto the mounting kit Figure 4 33 Installing the eLight actuator and power module 1 eLight actuator 2 eLight power module Step 4 Connect cables to the eLight system FusionModule800 Smart Small Data Center User Manual 4 Installatio...

Page 131: ...s Optional Refrigerant R410A If the one way length of the pipe connecting the indoor and outdoor units is less than or equal to 30 m no R410A refrigerant needs to be purchased If the length is greater than 30 m and less than or equal to 80 m R410A refrigerant needs to be purchased FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technolo...

Page 132: ...sponding to the measured outer surface temperature from Table 4 5 If the deviation between the saturation pressure and the measured internal is greater than 0 2 MPa the refrigerant does not meet the requirements and needs to be replaced Figure 4 35 Checking the refrigerant Table 4 5 Mapping between the saturation pressure and the saturation temperature for R410A Saturation Temperatu re C Gauge Pre...

Page 133: ...1 94 52 3 11 15 1 16 34 1 99 53 3 19 16 1 19 35 2 04 54 3 26 17 1 23 36 2 1 55 3 34 18 1 27 37 2 15 NOTE 1 MPa 10 bar 145 psi 10 2 kgf cm2 Oil Trap Figure 4 36 shows the oil trap specifications Figure 4 36 Oil trap unit mm Optional Gas Pipe Liquid Pipe and Thermal Insulation Foam Table 4 6 lists the specifications for pipes and thermal insulation foam FusionModule800 Smart Small Data Center User M...

Page 134: ... Drainpipe connector BSPT 1 2 inch delivered with the smart cooling product 2 Rigid pipe conversion adapter BSPP 1 2 inch connected to a rigid pipe with inner screw threads 3 Rigid pipe made of PP R or other material 4 Pagoda conversion adapter BSPP 1 2 inch connected to a pipe with inner screw threads 5 Hose clamp 6 Hose made of EPDM or other material NOTE The object shown in the broken line box ...

Page 135: ...e site ground resistance must be less than 0 1 ohm The fireproof level of the cables must be at least VB Table 4 7 lists the cables to be connected onsite When connecting cables fit them with protective hoses Table 4 7 Cable specifications Application Scenario Specifications Remarks Outdoor unit power cable optional Electrical power cable 600 V ZA RVV 3 x 6 mm2 black three core wires brown blue gr...

Page 136: ...rinciples are as follows If the outdoor unit is placed higher than the indoor unit the maximum height deviation between them should be less than or equal to 30 meters Install an oil trap every 5 6 meters in the vertical direction along the gas pipe If the indoor unit is placed higher than the outdoor unit the maximum height deviation between them should be less than or equal to 8 meters NOTICE The...

Page 137: ...gure 4 40 Layout of downward piping 1 Oil trap 2 Tilted gas pipe 3 Indoor unit 4 Tilted liquid pipe 4 2 6 3 Installing an Outdoor Unit 4 2 6 3 1 Installation Requirements FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 125 ...

Page 138: ...clean areas that are away from residential areas At a high place with strong winds install the outdoor unit against a wall to ensure the normal operating of fans Install baffle plates when necessary take this measure to prevent wind from blowing down the outdoor unit Try to install an outdoor unit against a wall If the site conditions cannot meet the requirements and the local outdoor temperature ...

Page 139: ...talling single outdoor unit If the outdoor unit cannot be installed against a wall or the local outdoor temperature may be below 10 C NetCol500 A018 or 0 C NetCol500 A020 or 10 C NetCol500 A021 place an air baffle at the air intake side of the outdoor unit based on the Figure 4 43 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technolo...

Page 140: ... air exhaust and intake of the smart cooling product being affected by the guardrail structure The picture is only for reference adjust based on the on site situation if necessary Optional Multiple Outdoor Units When multiple outdoor units are to be installed if they cannot be installed against a wall or the local outdoor temperature may be below 10 C NetCol500 A018 or 0 C NetCol500 A020 or 10 C N...

Page 141: ... tilt degree cannot exceed 15 Do not hold the fan guard on the shell Otherwise it will be deformed Do not touch the blades using hand or any other object Procedure Step 1 Determine the four mounting holes of the outdoor unit based on the installation dimensions and drill holes in the concrete base Step 2 Align the outdoor unit mounting holes with the holes in the concrete base and secure the outdo...

Page 142: ...d pipe needle valve of the indoor unit stop valve Figure 4 47 shows a smart cooling product stop valve Figure 4 47 Stop valve 1 Needle valve nut 2 Rear cover nut 3 Black plastic nut Procedure Step 1 Remove the rear cover nut from the stop valves using an adjustable wrench Step 2 Open the stop valves on the gas pipe and liquid pipe of the indoor unit in turn using a 5 mm hex key FusionModule800 Sma...

Page 143: ...sed When exhausting nitrogen ensure that the rubber hose is secured Otherwise personal injury will be caused as a result of the air current impact NOTICE There should be a great sound of airflow during the exhausting Figure 4 49 Exhausting nitrogen from an indoor unit 1 Pressure gauge 2 Gas pipe needle valve 3 Liquid pipe needle valve NOTE When exhausting nitrogen do not remove the valve plug in c...

Page 144: ...top pipe routing If there is only one smart cooling product only one assembly of gas pipe and liquid pipe is included Secure the entire pipe assembly to the cabinet interior onsite route pipes from the top or bottom based on site requirements Top Pipe Routing NOTICE When routing pipes from the top do not route the pipes over servers or other devices to protect the servers or other devices from bei...

Page 145: ... cabinet a Remove the ten cable rings from the side routed pipe in the rear of the IT cabinet as shown in Figure 4 52 Figure 4 52 Removing cable rings b Lay out pipes inside the IT cabinet as shown in Figure 4 53 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 133 ...

Page 146: ...e pipe layout Figure 4 54 Bottom pipe routing inside the converged cabinet Optional for installing the second smart cooling product Laying out pipes inside the IT cabinet Figure 4 55 shows the pipe layout FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 134 ...

Page 147: ... the smart cooling product are tightened Context Tools adjustable wrench 250 mm x 30 mm hex key 5 mm torque wrench 17 19 27 30 36 DANGER Before welding exhaust all nitrogen from the refrigerant pipe to avoid explosion and personal injury FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 135 ...

Page 148: ...ped with thermal insulation foam When a low temperature outdoor unit is configured the stop valve of the indoor unit should be wrapped with thermal insulation foam Procedure Step 1 Route pipes based on the engineering requirements and weld pipes in the medium segment by referring to Figure 4 57 NOTICE Exercise caution during welding to avoid burning components such as rubber rings inside the cabin...

Page 149: ...ities using alcohol or a wet cloth For any scratch contact Huawei technical support for replacement 2 Hold the copper pipe after the pipe nut with one hand and keep the pipe nut and the stop valve screw thread on the same center line Secure the pipe nut to the stop valve with the other hand and tighten the nut using a torque wrench as shown in Figure 4 58 NOTICE Tighten the liquid pipe stop valve ...

Page 150: ...for the nut of the liquid pipe stop valve is 70 N m and that for the nut of the gas pipe stop valve is 100 N m The torque greater than the failure torque will damage the screw thread Table 4 8 Torque requirements Item Pipe Nut Needle Valve Nut Rear Cover Nut Nut Size Tighteni ng Torque N m Nut Size Tighteni ng Torque N m Nut Size Tighteni ng Torque N m Liquid pipe stop valve 27 35 37 17 10 19 15 1...

Page 151: ...t stop valve pipe is installed the stop valve plug should be closed Open the stop valve plugs of the outdoor unit gas pipe and liquid pipe after vacuumization is complete to avoid refrigerant leaks Figure 4 59 Pipe ports on the outdoor unit Step 5 Weld the routed pipe and the pipe port reserved outside the cabinet End 4 2 6 6 Connecting Water Pipes The water pipes to be connected onsite include hu...

Page 152: ...ier Water Inlet Pipe Context This section applies only to models with humidifiers The smart cooling product water inlet pipe inside the cabinet can be routed from the bottom or top Determine the pipe routing mode based on site conditions Figure 4 61 shows how to connect a water inlet pipe FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei ...

Page 153: ...inlet pipe out of the smart cooling product fitting bag Route the pipe through the water inlet hole at the bottom and connect the pipe to the water inlet solenoid valve as shown in Figure 4 62 NOTICE Check that the water inlet solenoid valve is tightened with two to three circles of screw threads exposed Figure 4 62 Installing the humidifier water inlet pipe FusionModule800 Smart Small Data Center...

Page 154: ...ing to the actual conditions Figure 4 63 shows the top routing of the water inlet pipe Figure 4 63 Top routing of the water inlet pipe Route the bottom water inlet pipe a Break the rubber ring on the water pipe hole at the bottom of the cabinet b Figure 4 64 shows the bottom routing of the water inlet pipe FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05...

Page 155: ...ipe routing mode based on site conditions In top pipe routing connect the drainpipe to the check valve and then to the cabinet top The drain outlet reserved on the top of the cabinet connects to an external pipe over the drainpipe connector in the fitting bag In bottom pipe routing the drainpipe connects to an external pipe over the drainpipe connector in the fitting bag Figure 4 65 shows how to c...

Page 156: ... Hose clamp 6 Hose made of EPDM or other material NOTE The object shown in the broken line box is the drainpipe connector with outer screw threads delivered with smart cooling products The hose clamp part 5 is used in standard configuration Other parts are not configured and need to be purchased onsite Top Pipe Routing Step 1 Connect the check valve to the other end of the drainpipe as shown in Fi...

Page 157: ...when the drainpipe connects to the check valve It is recommended that the check valve be installed in a position lower than the smart cooling product otherwise water leaked from the check valve may affect the running of the smart cooling product After routing pipes secure them to the pipe component using cable ties The drainpipe inside the indoor unit should be wrapped with the thermal insulation ...

Page 158: ...p 1 Take out a drainpipe connector from the fitting bag and put the connector on the other end of the drainpipe as shown in Figure 4 68 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 146 ...

Page 159: ...n site requirements The drainpipe inside the indoor unit should be wrapped with the thermal insulation pipe in accessories 1 Break the rubber ring on the water pipe hole at the bottom of the cabinet 2 Figure 4 69 shows the bottom drainpipe routing FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 147 ...

Page 160: ...icated for testing the leaks of the indoor unit and the pipes connected to it The measuring range of the pressure gauge must be greater than or equal to 4 0 MPa and the tolerance range of the rubber hose must be greater than or equal to 4 5 MPa During the pressure preservation process do not remove the rubber hose and pressure gauge otherwise nitrogen may leak FusionModule800 Smart Small Data Cent...

Page 161: ...MPa NOTICE If the outlet pressure of the reducing valve is greater than 3 0 MPa components may be damaged Figure 4 70 Leakage test with nitrogen 1 Nitrogen cylinder 2 Reducing valve 3 Low pressure gauge 4 High pressure gauge 5 Gas pipe needle valve 6 Liquid pipe needle valve Step 3 Inject 3 0 MPa nitrogen and preserve the pressure for 24 hours The system pressure should stay constant under unchang...

Page 162: ...art cooling product control unit 1 Ground point 2 Rectifier 3 PSU 4 FE_2 port for connecting a smart ETH gateway PoE or LAN ports on the ECC 5 FE_1 port for connecting a smart ETH gateway PoE or LAN ports on the ECC 6 CAN_IN input port of the teamwork CAN and northbound RS485 port 7 RS485 12 V port for connecting the T H sensor 8 USB 9 DP 10 COM FE 11 CAN_OUT output port of the teamwork CAN and no...

Page 163: ...s the cable connections to the smart cooling product NOTICE After connecting the T H sensors in the aisle in series connect them to the RS485 port on the front panel of the smart cooling product control unit Do not pull cables J1 J2 J3 and J4 and their terminals casually Ensure that the cables are connected securely FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 ...

Page 164: ... L and N on the indoor unit INPUT1 port on the control unit 2 x 1 5 mm2 3 Signal cable for the indoor and outdoor units X2 1 X2 2 and X2 3 ports on the indoor unit P Q and E ports on the electric control box of the outdoor unit 3 x 16 AWG with the shield layer that can be grounded 4 J1 cable X101 X102 X103 and X104 ports on the indoor unit J1 port on the control unit 5 J2 cable X101 X102 X103 and ...

Page 165: ...able FE 1 port on the control unit If the smart ETH gateway is configured connect the cable to the PoE port on the smart ETH gateway If no smart ETH gateway is configured connect the cable to the WAN_2 port on the ECC800 Pro Four shielded twisted pairs 24 AWG 11 Ground cable Ground point on the control unit IT cabinet ground copper bar 4 mm2 12 Indoor unit power cable L converged cabinet XT2 9 XT2...

Page 166: ... signal cable routing of the second indoor unit Figure 4 75 Cable routing of the second indoor unit Figure 4 76 shows the power and signal cable routing of the third indoor unit FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 154 ...

Page 167: ... thermal insulation foam Check that all nitrogen has been exhausted from the indoor unit Ensure that stop valves for the gas pipe and liquid pipe of the indoor unit are open Verify that stop valves for the gas pipe and liquid pipe of the outdoor unit are closed Context Tools pressure gauge measuring range 4 0 MPa rubber hose withstanding a pressure of at least 4 5 MPa vacuum pump Procedure Step 1 ...

Page 168: ...tes or longer after making sure that the cooling system does not leak and that the pressure displayed on the vacuum pump is less than or equal to 60 Pa absolute pressure When the pressure stops dropping pump for another 10 minutes Step 5 After vacuumization close all valves of the pressure gauge and the vacuum pump without disconnecting it Preserve the pressure for 10 minutes and verify that the a...

Page 169: ...nut of indoor unit and outdoor unit Step 9 Wrap the gas pipe stop valve liquid stop valve and the pipes connected to the stop valve with stop valve sponge the thickness is 5 mm End 4 2 7 Installing Power Supply and Distribution Devices 4 2 7 1 Installing Lithium Batteries Procedure Step 1 Install and check according to the installation guide If there are no floating nuts on both sides of the rack ...

Page 170: ...e installed certain clearances should be reserved The space for each ESM should be at least 3 U The ESMs cannot be directly stacked or vertically placed Install ESMs from bottom to top It is advised to install ESMs on four layers Figure 4 79 Correct installation End 4 2 7 2 Installing a PDU2000 Context The PDU2000 can be half height full height or horizontal Select the PDU2000 model based on the p...

Page 171: ...ing screws Figure 4 80 Installing a PDU2000 in the Converged Cabinet with lithium batteries NOTE The preceding figure shows how to install the PDU2000 inside the Converged Cabinet where the customer installs their equipment FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 159 ...

Page 172: ... 1 Open the rear door of the cabinet 2 Secure the PDU2000 Figure 4 82 Installing a PDU2000 Step 3 Optional Install an intelligent full height PDU2000 1 Open the rear door of the cabinet 2 Install a mounting kit for the PDU2000 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 160 ...

Page 173: ...84 Installing a PDU2000 Step 4 Optional Install a horizontal PDU2000 1 Open the rear door of the cabinet 2 Secure the horizontal PDU2000 to the installation position using screws FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 161 ...

Page 174: ...binet with lithium batteries End 4 2 7 3 Optional Installing an ATS Subrack 1 Install guide rails 2 Install the subrack FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 162 ...

Page 175: ...talling Cable Troughs If cable troughs are configured perform the following steps to install them 4 2 8 1 Removing a Binding Plate Prerequisites A cable trough is determined to be installed Context Install a binding plate at the top of the cabinet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 163 ...

Page 176: ...ide Cable Trough Context Install two 600 mm wide cable troughs on the top of every 600 mm wide cabinet When installing cable troughs first install two cable troughs at the top of the end cabinet and then install the other cable troughs at the top of other cabinets along the aisle in sequence Figure 4 89 shows a 600 mm wide cable trough Its BOM number is 21501142 FusionModule800 Smart Small Data Ce...

Page 177: ...cabinet top Install strong current power cable troughs at red binding plates and weak current power cable troughs at blue binding plates Procedure Step 1 Keep a vertical plate of the cable trough flush with the top surface of the cabinet and clamp the clasps into the square holes in the first row counting from the front door to the rear door as shown in Figure 4 90 Figure 4 90 Clamping a vertical ...

Page 178: ... as shown in Figure 4 92 Figure 4 92 Installing the other vertical plate Step 4 Press a supporting plate along the two vertical plates down to the place between the four clasps and the cable bridge as shown in Figure 4 93 Ensure that the supporting plate is fully into the clasps NOTE When installing the supporting plate do not remove the grommet strip on the U shaped trough FusionModule800 Smart S...

Page 179: ...e two adjacent square holes in the middle In actual conditions determine the square holes as required Figure 4 94 Installing a partition plate Step 6 Install adjacent cable troughs in the same way Step 7 Rotate the interconnecting wrench and clamp it into the clasps until the wrench is horizontal as shown in Figure 4 95 This operation interconnects the cable troughs FusionModule800 Smart Small Dat...

Page 180: ...lling Monitoring Devices 4 2 9 1 Installing the SIM Card and Antenna If a subscriber identity module SIM card and an antenna are configured perform the following steps to install them Procedure Step 1 Record the positions of the signal cables connected to the panel of the ECC800 Pro main control module and then disconnect the signal cables Step 2 Remove the ECC800 Pro main control module and then ...

Page 181: ...e cabinet top 2 Route the antenna cable into the cabinet through the signal cable hole at the top of the cabinet and then to the appropriate port on the ECC800 Pro 3 Connect the antenna cable to the antenna port on the ECC800 Pro Figure 4 98 Installing an antenna cable End 4 2 9 2 Installing a PAD Prerequisites Cabinets have been combined FusionModule800 Smart Small Data Center User Manual 4 Insta...

Page 182: ...pport to match the dimensions of the PAD to be installed Figure 4 100 Adjusting screws 1 Screws Step 2 Remove nuts from the PAD support insert the support into the mounting holes on the cabinet front door and reinstall the nuts to secure the support to the front door FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 17...

Page 183: ...TICE Ensure that the PAD is installed securely and reliably Figure 4 102 Installing a PAD Step 5 Connect the cable from the USB port on the ECC800 Pro to the charging port on the PAD NOTICE If the PAD screen needs to remain on for a long time during usage adjust the brightness to below 80 End FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Hua...

Page 184: ...LAN switch installation position in the IT cabinet and install guide rails and floating nuts Step 2 Install the mounting ears delivered with the LAN switch and secure the LAN switch to the rack rails in the front of the cabinet NOTE This section describes only the installation method The actual product appearance prevails FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Iss...

Page 185: ...N switch NOTE Two power modules need to be installed for a 24 port LAN switch onsite End 4 2 9 4 Installing T H Sensors and Aisle Temperature Sensors 02312PBL 4 2 9 4 1 Layout of T H Sensors and Temperature Sensors NOTE The figures are for reference only Install the devices based on site requirements If the total number of IT cabinets and network cabinets is less than six two aisle T H sensors are...

Page 186: ...x the second NetCol is installed in the IT cabinet to the right of the Converged Cabinet If more than six IT cabinets and network cabinets are configured the second or third NetCol is installed in the middle cabinet between the Converged Cabinet and the farthest cabinet Figure 4 107 T H sensor configuration for an even number of cabinets Figure 4 108 T H sensor configuration for an odd number of c...

Page 187: ...ep 1 Install T H sensors 1 Open the front door of a cabinet 2 Install the T H sensor base at the right post position of the IT cabinet about 1 6 m high above the floor in the aisle and then clamp the T H sensor onto the base FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 175 ...

Page 188: ...ch 8 is used to switch the temperature display mode The device address is set in binary mode 1 is the least significant bit and 6 is the most significant bit ON indicates 1 and OFF indicates 0 The address range is 1 to 4 Figure 4 112 DIP switch definitions for T H sensors NOTE The numbers 1 4 indicate the DIP switch settings of the T H sensors FusionModule800 Smart Small Data Center User Manual 4 ...

Page 189: ...F OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF Step 3 Connect the communications cables to the T H sensors NOTE The figure shows the layout of eight cabinets The actual cable connections depend on the onsite configuration Figure 4 113 Cable connections to T H sensors and temperature sensors FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 0...

Page 190: ...e sensor to the cabinet and keep them 20 mm away from the sensor probe Temperature sensors must not be in touch with metal parts or cabinets Ensure that the temperature sensor on the rear door of the cabinet is installed on the side without a PDU2000 Verify that the temperature sensors face the inside of the cabinet to ensure accurate measurement of cabinet interior temperatures Install other temp...

Page 191: ...cts three T H sensors are configured 4 2 9 5 1 T H Sensor Layout NOTE The figure is for reference only Install the devices based on site requirements The NetCol remote T H sensors are attached to the leftmost and rightmost IT cabinets near aisle columns Installing a T H sensor when only one NetCol is configured FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 ...

Page 192: ...s are configured Optional Figure 4 117 T H sensor configuration Installing T H sensors when three NetCols are configured Optional a Configure T H sensors in scenario 1 Figure 4 118 T H sensor configuration b Configure T H sensors in scenario 2 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 180 ...

Page 193: ...be adjusted as required Step 2 Set the DIP switch address of the T H sensor to 11 Table 4 11 DIP switch setting on a T H sensor Address DIP Switch Sequence No 1 2 3 4 5 6 11 ON ON OFF ON OFF OFF NOTICE The default addresses of T H sensors purchased from Huawei are 1 After the addresses are set set Cold aisle sensor to Enable on the ECC800 Pro WebUI Otherwise the T H sensors will not work The path ...

Page 194: ...he camera installation method see the documents delivered with the camera Install the camera at the front right position in the aisle and ensure that the camera can monitor the entire front area of the smart module especially PAD operations Procedure Step 1 Align the mounting holes in the dome camera base with those in the mounting plate and screw the camera to the mounting plate as shown in Figur...

Page 195: ...lly 0 75 degrees vertically or 0 355 degrees in the revolving direction to achieve an appropriate angle Figure 4 122 shows the adjustment methods Figure 4 122 Triple axis adjustment Step 2 Install the mounting plate with the camera at the top of the front door of the end cabinet as shown in Figure 4 123 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Co...

Page 196: ...the ECC800 Pro to energize the camera 3 Appoint one person to log in to the camera control software and observe the image on the monitor and another person to rotate the lens to cover the target area 4 Appoint one person to observe the image displayed on the monitor and another person to adjust the Zoom screw T to W to achieve an appropriate angle of coverage 5 Assign one person to observe the ima...

Page 197: ...camera base as shown in Figure 4 125 This prevents the blockage of the infrared light and photoresistor Figure 4 125 Installing an inner cover Step 6 Install the front cover of the camera in the direction shown in Figure 4 126 and tighten the screws on the front cover NOTICE Before installing the camera front cover remove the protective film from it FusionModule800 Smart Small Data Center User Man...

Page 198: ...move the two black screws on the rear of the chassis cover and take off the chassis cover Figure 4 127 Removing the chassis cover 2 Remove two black screws on each side of the chassis and the silvery white one on top of the hard disk tray raise the hard disk tray by 45 degrees and take out the upper and then lower layers of hard disk tray Figure 4 128 Removing the hard disk tray FusionModule800 Sm...

Page 199: ...cing downwards hold the screw in the red framed part to lower the hard disk tray until it is level and fasten the black screws on the left and right sides and the white screw on the top Figure 4 130 Fastening the screw on the panel and the screws on the hard disk tray 5 Connect data and power cables to hard disks Connect hard disk cable ports P0 P3 to hard disks on the lower layer hard disk tray a...

Page 200: ...to 800 mm for additional purchase if required for IVS1800 installation Do not attach rubber feet on the IVS1800 to save space during cabinet installation 1 Confirm the installation location of guide rails in the cabinet Install cage nuts two at the front and three at the back on each side to secure the guide rails at the proper position in the cabinet as shown in the lower left figure The lower ri...

Page 201: ...wer right figure CAUTION Before installing a guide rail check the F L F R labels on the guide rail to identify whether it is for the left or right and which part is the front or rear F L indicates the front end of the left guide rail and F R indicates the front end of the right guide rail Figure 4 134 Installing a guide rail 3 Install a filler panel for guide rails Fasten the M6 screws to install ...

Page 202: ...nuts 5 Install mounting ears Use a PH2 screwdriver to secure the mounting ears to both sides of the front panel of the device with four screws on each side When the device is near the front door of the cabinet fasten screws in hole groups 1 and 2 when the device is near the rear door fasten screws in hole groups 2 and 3 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue...

Page 203: ...g ears on the front mounting bars of the cabinet as shown in the lower right figure Figure 4 138 Securing the device Step 3 Power on the device 1 Turn on the power switch 2 Check the indicators on the front panel of the device for its running status End 4 2 9 8 Installing a Smart ETH Gateway and an ETH Converter If a smart ETH gateway is configured perform the following steps to install it Prerequ...

Page 204: ... the top of the cabinet Figure 4 139 Position 1 for installing a smart ETH gateway 1 Smart ETH gateway If M shaped cable troughs are not deployed for the Smart Module install the smart ETH gateway on the top of the cabinet Figure 4 140 Position 2 for installing a smart ETH gateway 1 Smart ETH gateway FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyr...

Page 205: ...42 Figure 4 142 Installing a smart ETH gateway 1 Align the upper slot of the guide rail for the smart ETH gateway with the upper part of the guide rail and pre mount it onto the guide rail 2 Press the lower part of the smart ETH gateway to clamp the smart ETH gateway onto the guide rail 3 Shake the smart ETH gateway in different directions to ensure that it is reliably installed Step 3 Connect the...

Page 206: ... Converged Cabinet The water detection cable and water detector are interconnected using the conversion cable A single water detection cable is 5 meters long If a longer cable is required connect the male connector of a water detection cable to the female connector of another One water detector can be connected to a maximum of nine water detection cables Figure 4 143 Detector positions 1 Water det...

Page 207: ...cable 5 Water detection cable end A connected to the conversion cable 6 Water detection cable Figure 4 145 Laying out the water detection cable NOTE The following uses the five cabinet layout as an example 1 Water detector cable 2 Water detector FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 195 ...

Page 208: ...detector as shown in Figure 4 146 Figure 4 146 Removing the cover from the water detector 2 Install the water detector bottom plate in the Converged Cabinet using two M3 screws as shown in Figure 4 147 NOTE The screws for installing a water detector bottom plate are in the Converged Cabinet fitting bag FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Cop...

Page 209: ...e end B connected to the water detection cable 2 Water detection cable end A connected to the conversion cable NOTE The water detection cable and conversion cable are interconnected through the male and female connectors Step 3 Connect the other end of the conversion cable to the water detector as shown in Figure 4 149 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue ...

Page 210: ...ep 7 Step 6 Drill holes in the floor with the same dimensions as the expansion bolts for the fastener Use the expansion bolts to secure the fastener to the floor as shown in Figure 4 150 Figure 4 150 Installing fasteners NOTICE When laying out the water detection cable ensure that the water detector is close to the Converged Cabinet to facilitate further cable connections Step 7 Place the water de...

Page 211: ...he following steps to install it Procedure Step 1 Place the water sensor on the floor under the Converged Cabinet Step 2 Route the water sensor cable through the cable hole in the lower cover plate of the Converged Cabinet for the hot aisle Step 3 Connect it to the water sensor cable connected to the ECC Figure 4 152 Signal Cable Routing End FusionModule800 Smart Small Data Center User Manual 4 In...

Page 212: ...e its cover Figure 4 153 Removing the cover of a waterproof box Step 2 Take out the delivered marking off template and mark the mounting holes in the installation position Step 3 Drill holes and install expansion anchor bolt sleeves 1 Drill holes into the wall to a depth of 45 50 mm using a hammer drill Partially tighten the expansion bolts and vertically insert them into the holes Knock the expan...

Page 213: ...pansion sleeve 6 Wall 7 Rubber mallet 8 Socket wrench Step 4 Secure the waterproof box to the wall Figure 4 155 Securing a waterproof box Step 5 Take out the access actuator and clamp it along the guide rail FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 201 ...

Page 214: ...stalled Figure 4 156 Installing an access actuator Step 6 Reinstall the waterproof box cover Figure 4 157 Reinstalling the waterproof box cover End 4 2 9 12 Optional Installing an In Room Double Door Magnetic Lock Prerequisites Verify that the room door is a revolving double swing wooden door and that the door frame is wider than 42 mm The cable routes are planned FusionModule800 Smart Small Data ...

Page 215: ...ure 4 158 Figure 4 158 Marking mounting holes 1 Door frame 2 Cutout template 3 Door panel Step 3 Remove the hoisting strip using the delivered hex key NOTE Four hex socket screws need to be removed in this step Figure 4 159 Removing the hoisting strip Step 4 Secure the hosting strip using the delivered screws as shown by 1 in Figure 4 160 NOTICE Pay attention to the direction of the hoisting strip...

Page 216: ...pins of a magnet 2 Insert the assembled magnet into the positioning holes in the door and secure the magnet to the door using the screws and rubber pad delivered with the electronic lock as shown in Figure 4 162 NOTE When securing the magnet to the door panel do not over tighten the screws so that the rubber pad is elastic The rubber pad will adjust the magnet to a correct position because of its ...

Page 217: ... a revolving single swing wooden door and that the door frame is wider than 42 mm The cable routes are planned Context The BOM number of a single door magnetic lock is 02070081 A single door magnetic lock is installed on a room door Procedure Step 1 Fold the cutout template delivered with the device 90 degrees along the dotted line as shown by 2 in Figure 4 163 Step 2 Close the door place the cuto...

Page 218: ...p Figure 4 164 Removing the hoisting strip Step 4 Secure the hosting strip using the delivered screws as shown by 1 in Figure 4 165 NOTICE Pay attention to the direction of the hoisting strip and ensure that the bulging surface of the magnetic lock faces the magnet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 206 ...

Page 219: ...re 4 166 Connecting cables 1 Cable outlet Step 6 Secure the magnetic lock as shown by 2 in Figure 4 165 Step 7 Install the magnet 1 Take out the magnet and knock the positing pins of the magnet into the magnet using a rubber mallet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 207 ...

Page 220: ... Figure 4 168 Installing a magnet 1 Rubber pad Step 8 Optional Adjust the magnet 1 If the magnet cannot attract the door properly after power on place a magnetized metal part near the magnet to check whether the magnet provides a proper magnetic force 2 If the magnetic lock and the magnet do not work properly check and troubleshoot the circuit End 4 2 9 14 Optional Installing an In Room Fingerprin...

Page 221: ...re 4 169 Installing a fingerprint and card reader with a keypad Step 2 Mark the mounting holes using a marker and drill holes using a hammer drill Figure 4 170 Marking mounting holes unit mm Step 3 Install the baseplate as shown by 3 in Figure 4 169 Step 4 Route the cable of the fingerprint and card reader with a keypad through the cable hole in the baseplate as shown by 4 in Figure 4 169 FusionMo...

Page 222: ...der is 02070173 It is recommended that the device be installed outside a room 1 4 1 6 m above the floor Do not install the product in a place with heavy dust or exposed to sunlight Procedure Step 1 Remove the screws set aside from the fingerprint and card reader and take off the baseplate as shown by 1 in Figure 4 171 Figure 4 171 Installing a fingerprint and card reader Step 2 Mark the mounting h...

Page 223: ... baseplate as shown by 5 and 6 in Figure 4 171 End 4 2 9 16 Optional Installing an In Room Card Reader with a Keypad Context The BOM number of a card reader with a keypad is 02070172 It is recommended that the device be installed outside a room 1 4 1 6 m above the floor Do not install the product in a place with heavy dust or exposed to sunlight Procedure Step 1 Remove the screws set aside from th...

Page 224: ...card reader with a keypad through the cable hole in the baseplate as shown by 4 in Figure 4 173 NOTE The card reader with a keypad is connected to the access actuator by a network cable Step 5 Check that cables are correctly connected Step 6 Secure the card reader with a keypad to the baseplate as shown by 5 and 6 in Figure 4 173 End FusionModule800 Smart Small Data Center User Manual 4 Installati...

Page 225: ...the exit button NOTE The exit button is connected to the access actuator by a network cable Step 5 Route the cable through the cable hole Step 6 Reinstall the exit button and the cover End 4 2 9 18 Optional Installing an In Room Emergency Door Release Button Context The BOM number of an emergency door release button is 02070053 It is recommended that the device be installed outside a room 1 6 m ab...

Page 226: ...rill and route cables out of the cable hole Step 4 Install the emergency door release button Figure 4 177 Installing an emergency door release button 1 Install the base of the emergency door release button as shown by 1 in Figure 4 177 2 Install the glass panel of the emergency door release button as shown by 2 and 3 in Figure 4 177 3 Tighten screws of the emergency door release button using a Phi...

Page 227: ...way from the plug except for special circumstances For example a label shall not be attached to the bending part of a cable or attached in some positions that may affect cable installation If a label conflicts with a cable tie attach the label to the outer side of the cable tie Attach labels to both ends of a cable Requirements for Neatly Routing and Binding Cables To route and bind cables in an a...

Page 228: ...en arrangement by thickness conflicts with arrangement by color Figure 4 180 Binding cables in different colors Cable Spacing Requirements Comply with the following requirements if possible to lay out different types of cables 1 Separate AC and DC power cables from diverse non shielded signal cables Keep the cable spacing greater than 100 mm or use grounded metal for isolation purposes Do not bind...

Page 229: ...o prevent stress on certain wires as shown in Figure 4 182 Figure 4 182 Cable connections 5 Protect cable holes in a metal kit with grommet strips Alternatively ensure that the holes are rounded free from burrs or sharp edges 6 Keep cables far away from heat sources such as radiators and heat vents If unavoidable take heat resistant measures 7 Keep cables far away from operating components such as...

Page 230: ...e 4 183 Cutting off the excess part of a cable tie 3 Do not use cable ties at a place where the cables are bent Otherwise the cable cores may break due to strong stress as shown in Figure 4 184 Figure 4 184 Binding cables in a bending area 4 Ensure that the cable ties are wrapped and secured in the same direction and do not generate interference with subsequent operations as shown in Figure 4 185 ...

Page 231: ...mer can purchase power cables as required The recommended specifications of mains input power cables are as follows 7 5 kW and 8 5 kW loads cable BOM code 25030893 Electronic Electric Cable 600V 1000V ZA YJV 5x10mm2 Black 5Cores Yellow Green Red Blue Black 80A CE FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 219 ...

Page 232: ...70 plastic cable ties that can be installed on holes at the top of the cabinet for binding cables as shown in Figure 4 187 Figure 4 187 Installing a plastic cable tie FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 220 ...

Page 233: ... Cable Route Figure 4 188 Smart ETH gateway cable route 1 Signal cable 2 Power cable FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 221 ...

Page 234: ... 1 Connect the general ground point in each cabinet to the general ground bar in the Converged Cabinet 2 Connect the general ground bar in the Converged Cabinet to the floor ground bar or collective ground bar FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 222 ...

Page 235: ...re 4 190 Converged Cabinet ground bar Figure 4 191 Cabinet ground point FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 223 ...

Page 236: ... 5 1 1 Cable Routing Description Figure 4 193 Cable holes for routing cables over the top of the Converged Cabinet 1 Holes for pipes of smart cooling products 2 Power cable holes 3 Signal cable holes 4 Input power cable holes FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 224 ...

Page 237: ...utlets of cabinets for ease of cable routing Rodent proof mesh Use diagonal pliers to cut cable inlet and outlet holes on rodent proof meshes based on the number and specifications of cables as shown in Figure 4 195 Wire bushing Cut a cross in the middle of a wire bushing using an electrician s knife as shown in Figure 4 196 Figure 4 195 Cutting a hole in a rodent proof mesh FusionModule800 Smart ...

Page 238: ... 1 Place binding cables routed across the cabinet interior 4 3 5 1 2 Optional Connecting Cables to the ATS Subrack 1 Connect the ATS input power cables NOTICE Connect the ground cable first 2 Connect output power cables from the ATS to the Converged Cabinet FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 226 ...

Page 239: ...Cabinet see the Electrical Wiring Diagram The power distribution subrack position in the cable connection description is for reference only The actual position prevails Procedure Step 1 Connect input power cables to the PDU 1 Remove the transparent protective panel at the rear of the PDU 2 Connect input power cables to the PDU FusionModule800 Smart Small Data Center User Manual 4 Installation Guid...

Page 240: ...evails If the cable length needs to be adjusted adjust the cable to a proper length based on the actual position of the power distribution module crimp the terminal and then connect the cable Crimp a cord end terminal on the live wire as shown in Figure 4 200 Crimp an OT terminal on the PE wire and neutral wire as shown in Figure 4 201 Figure 4 200 Preparing a cord end terminal 1 Cable 2 Cord end ...

Page 241: ...s 5 Heat gun Procedure Step 1 Connect output power cables to the PDU Figure 4 202 Connecting output power cables to the PDU for IT cabinets in Asia Europe and Africa FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 229 ...

Page 242: ...ing Cables connect to the same positions on the power distribution subrack irrespective of whether cables are routed through the top or bottom of the Converged Cabinet but the cable routes inside the cabinet are different FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 230 ...

Page 243: ... for the signal cable and water sensor cable 3 Holes for the input power cable and battery cabinet power cable 4 Holes for the smart cooling product refrigerant liquid pipe 5 Holes for the smart cooling product refrigerant gas pipe FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 231 ...

Page 244: ...ls Phillips screwdriver flat head screwdriver diagonal pliers protective gloves Material cable tie Procedure Step 1 Connect the PDU2000 cables NOTICE Connect cables to the PDU2000 based on the type of the PDU2000 and the silk screen on the wiring port The following cable connection is for reference only FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Co...

Page 245: ...the opening Step 3 Lay out the PDU2000 cables on the top of the cabinet and reinstall the rodent proof mesh Step 4 Connect the cord end terminal on the IT cabinet output power cable routed out of the Converged Cabinet to the PDU2000 cable port in the cabinet as shown in Figure 4 207 FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Techno...

Page 246: ... The BOM number of the intelligent PDU2000 is 02120701 The installation position of the intelligent PDU2000 depends on the actual delivery Procedure Step 1 Connect the signal cable from the COM port on the intelligent PDU2000 to the COM port on the ETH converter Step 2 Connect a cable from the POE port on the ETH converter to the POE port on the smart ETH gateway FusionModule800 Smart Small Data C...

Page 247: ...nts The figure is for reference only Figure 4 208 Connecting signal cables for the intelligent PDU2000 1 ETH converter 2 Smart ETH gateway End Example The signal cable is delivered with the materials If it is lost use a standard network cable FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 235 ...

Page 248: ...r Function Description 1 Orange and white RS485 A 2 Orange RS485 B 3 Green and white NC 4 Blue RS485 A 5 Blue and white RS485 B 6 Green NC 7 Brown and white NC 8 Brown NC FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 236 ...

Page 249: ...re connected Table 4 14 Recommended power cable specifications Model Wiring Termina l Numbe r of Phases Rated Voltage External Circuit Breaker Cable Cross section al Area Terminal Type Torque for Tighteni ng Bolts 6 kVA AC input and output 1 220 V AC 230 V AC 240 V AC 32 A type D 6 mm2 OT 6 mm2 M5 terminal 2 N m Battery input 48 V DC 125 A type D 25mm2 OT 25 mm2 M8 terminal 7 N m NOTE If customers...

Page 250: ...e UPS b Connect communications cables between lithium batteries From bottom to top connect the COM_OUT port on the lithium battery to the COM_IN port on the lithium battery above it c A build out resistor needs to be installed on the COM OUT port of the lithium battery on the top Figure 4 210 Connecting cables between the batteries and the UPS 1 UPS rear 2 BCB box 4 3 6 Management System Cable Con...

Page 251: ...of another network cable to the RS485_IN port on the electronic clasp lock of the first cabinet among even numbered cabinets and connect the other end of the network cable to the COM3 port on the ECC800 Pro Figure 4 211 Installing cabinet electronic clasp lock cables NOTE It is recommended that inter cabinet cables be routed from the top of the cabinets End 4 3 6 2 Connecting a Monitoring Cable to...

Page 252: ... the smart ETH gateway to the 53 5VDC_OUT1 or 53 5VDC_OUT2 port on the ECC800 Pro using a power cable Step 3 Connect the FE_2 port on the smart ETH gateway to the LAN_2 POE port on the ECC800 Pro using a network cable End 4 3 6 3 Connecting IVS Cables Prerequisites Cables have been prepared Procedure Step 1 Connect one end of the ground cable to the ground terminal on the device and the other end ...

Page 253: ...n the power switch on the panel to start the device End 4 3 6 4 Connecting a Cable to the WLDS900 Water Sensor Prerequisites Water sensor cables have been routed The monitoring cables to be connected have been prepared Procedure Step 1 Connect one end of the network cable that has been routed to the water detector to the AIDI_3 port on the ECC800 Pro FusionModule800 Smart Small Data Center User Ma...

Page 254: ...ave been prepared It is recommended that cables of the in room access control system be routed through a trough in a wall NOTE Cables installed on the surface of a wall need to be routed through a pipe for protection FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 242 ...

Page 255: ...tep 1 Remove the covers from the waterproof box and cable holes of the access actuator Step 2 Connect cables by referring to Figure 4 216 1 Connect the smart ETH gateway to the access actuator using a cable 2 Connect the single double door magnetic lock to the access actuator using a cable 3 Connect the access controller to the access actuator using a cable 4 Connect the exit button to the access ...

Page 256: ...for a fingerprint and card reader 04093981 03 cable BOM number for a fingerprint and card reader with a keypad 04093981 04 4 Cable BOM number 04093981 05 5 Cable BOM number 04093981 06 Step 3 Reinstall the covers of the waterproof box and cable holes End 4 3 6 6 Optional Connecting Cables to the ATS Subrack Prerequisites The ATS subrack has been installed The required cables have been prepared Fus...

Page 257: ...inguishing non monitoring cable 3 Optional Connect a DG monitoring cable 4 4 Verifying the Installation Smart Cooling Product Installation Check Table 4 15 Indoor unit installation checklist Item Check That Check Result Fan The fan is secured Passed Failed The fan has no foreign matter inside Passed Failed Liquid level detector The liquid level detector is secured Passed Failed FusionModule800 Sma...

Page 258: ...esult Pipe connectors are correct The refrigerant pipe tilts and has supports Passed Failed The hose clamps and cable ties of the drainpipe are secured Passed Failed The refrigerant pipe and water pipe are wrapped with thermal insulation foam Passed Failed All pipes have been checked for leaks Passed Failed Water pipe joints have been sealed by sealant Passed Failed The pipes are not bent by a lar...

Page 259: ... and complete Passed Failed 8 The cabinet has no waste tape cable ties paper or packing materials around it Passed Failed 9 All components are properly installed and no component is left onsite Passed Failed 10 Block empty cable holes using plugs or lids Passed Failed Cable Installation Check Table 4 19 Cable installation check items No Check That Check Result 1 All cable joints are secured proper...

Page 260: ... smart cooling product input voltage is within the range of rated voltage 10 and the input frequency is within the range of rated frequency 3 Hz Passed Failed 4 The length of ground cables and power cables is correct Passed Failed 5 Lugs for power cables and PGND cables are soldered or crimped securely Passed Failed 6 Power cables and PGND cables are routed and bundled separately from other cables...

Page 261: ...esult 12 DIP switches on devices are correctly set Passed Failed Customer Sign Check Data FusionModule800 Smart Small Data Center User Manual 4 Installation Guide Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 249 ...

Page 262: ...t breakers NOTE If the indicator of an SPD module is green the SPD module is running properly If the indicator is red the SPD module is faulty and must be promptly replaced Step 2 Switch on the power input circuit breaker outside the cabinet to power on the cabinet NOTE If the green power indicator on the cabinet front panel lights up the cabinet is powered on properly Step 3 Optional Check that t...

Page 263: ...cuited Cables and terminals are securely connected Battery cables and terminals are connected correctly and voltages comply with industry standards Power cables and signal cables are correctly identified Cables are neatly routed and securely bound Devices are installed and cables are routed in ways that facilitate modification capacity expansion and maintenance The UPS is properly grounded The vol...

Page 264: ...capacity Battery Capacity Description Default value 4 200 Ah Value range 1 50 Ah to 48 2400 Ah The value increases by 50 Ah each time you press SELECT Step 3 Press and hold ON MUTE for more than 5s Release the button when you hear a beep sound The UPS starts to work in normal mode FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Tech...

Page 265: ...nverter to Transfer the UPS to the No Output State Step 1 Shut down loads Step 2 Perform the startup operation on the UPS The UPS shuts down the inverter and transfers to bypass mode If mains parameters are inconsistent with bypass parameters the UPS transfers to standby mode Step 3 Switch off the AC input circuit breaker Km and output circuit breaker Q for the UPS After all indicators turn off an...

Page 266: ...s will enter the bypass mode Switch on the AC output circuit breakers Q1 and Q2 The UPSs enter the standby screen and the parallel system works in bypass mode Press and hold SELECT for 1s on a non setting screen to access the login screen for parameter settings The initial password is 123 Enter the correct password to access the UPS setting mode Figure 5 5 Password setting screen FusionModule800 S...

Page 267: ... and branch output circuit breakers for the parallel system to start loads one by one End 5 1 1 3 2 Shutting Down a Parallel System Shutting Down a Single UPS in the Parallel System Step 1 Perform the shutdown operation for a UPS in the parallel system Then the UPS shuts down and generates no output Other UPSs work without being affected Step 2 Disconnect the parallel communications cables of the ...

Page 268: ... Transferring the Parallel System to No Output Mode Step 1 Shut down loads Step 2 Perform the shutdown operation on each UPS in the parallel system All UPSs shut down the inverters and transfer to bypass mode Step 3 Switch off the AC input circuit breakers Km1 and Km2 and the general AC input circuit breaker Km for the UPS system Switch off the AC output circuit breakers Q1 and Q2 and the general ...

Page 269: ...he lithium battery communicates properly with the SMU If the indicator blinks fast 4 Hz the communication is interrupted In this case check that the communications cable is properly connected Step 3 Observe the lithium batteries for 15 minutes The batteries are running properly if the alarm indicators are off Step 4 Hold down the MANUAL ON OFF buttons on the lithium battery panels for more than 5s...

Page 270: ...lves on the gas pipe and liquid pipe for the outdoor unit are open Procedure Step 1 Switch on the circuit breakers for the indoor and outdoor units on the upstream PDB NOTICE The electric heating belt of the crankcase starts working Before starting the compressor ensure that the electric heating belt of the crankcase has been preheated for more than 12 hours Otherwise Huawei will not repair the co...

Page 271: ...smart cooling products in the same group cannot be the same address range 1 32 The smart cooling product addressed 1 is the master one that collects processes and delivers data You are advised to set the value to an integer in the range of 1 to the number of smart cooling products in the current group Procedure Step 1 Log in to the ECC800 Pro WebUI as admin Step 2 Choose Monitoring Cooling NetCol5...

Page 272: ...unning avoidance Table 5 2 Setting teamwork control parameters for three smart cooling products Parameter Smart Cooling Product No 1 2 3 Teamwork function Enable Enable Enable Teamwork group no 1 1 1 Air conditioner address 1 2 3 Number of air conditioners in this group 3 Number of running air conditioners in this group 3 Rotation Enable Rotation period The parameter can be set by the day ranging ...

Page 273: ...rt Cooling Product No 1 2 3 4 Teamwork function Enable Enable Enable Enable Teamwork group no 1 1 1 1 Air conditioner address 1 2 3 4 Number of air conditioners in this group 4 Number of running air conditioners in this group 4 Rotation Enable Rotation period The parameter can be set by the day ranging from one day to 30 days as required FusionModule800 Smart Small Data Center User Manual 5 Power ...

Page 274: ...ol cable connection and teamwork control parameter settings End 5 2 2 3 Setting the Maximum Outdoor Fan Speed If the equipment room is near a noise sensitive place such as an office or a meeting room limit the rotational speed of the indoor fan within 80 to lower the noise Procedure Step 1 Choose Monitoring Cooling NetCol5000 A1 Running Parameters Indoor Fan Parameters set Max speed of indoor fan ...

Page 275: ...pipe length L L should be less than or equal to 80 metes If L exceeds 80 meters contact Huawei technical support Table 5 4 Equivalent length of pipe assemblies Pipe Outer Diameter 90 degree Bend 180 degree Bend 5 8 inch gas pipe 0 3 m 0 6 m 3 8 inch liquid pipe 0 2 m 0 4 m 7 8 inch gas pipe 0 42 m 0 8 m 1 2 inch liquid pipe 0 25 m 0 5 m Table 5 5 lists how to calculate the amount of refrigerant to...

Page 276: ...hoose Monitoring Cooling NetCol5000 A1 The page for commissioning smart cooling products is displayed NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails If no manual operation is performed within 25 seconds after you click On the device will automatically run following the preset logic and the compressor and in...

Page 277: ...ssure and check whether the suction pressure and exhaust pressure of the compressor are within the proper ranges Choose Running Info Electronic Expansion Valve Information check EEV suction overheating degree The proper range is 4 15 C Table 5 6 lists the proper exhaust pressure ranges NOTE The proper range of the air suction pressure is 0 7 1 6 MPa and the pressure ratio air exhaust pressure to a...

Page 278: ...edle valve nuts when the charge is complete Check whether a needle valve leaks by applying soapy water to the valve vent or using a halogen leak detector If it leaks contact Huawei technical support Figure 5 8 Charging refrigerant 1 Refrigerant cylinder 2 Electronic balance 3 Pressure gauge 4 Connection nut 5 Gas pipe needle valve 6 Liquid pipe needle valve 3 On the Diagnostic Mode Parameters page...

Page 279: ...ows 7 and later versions It is recommended that the screen resolution be 1366 x 768 or higher Browser IE9 and later versions Firefox and later versions Chrome and later versions Procedure Step 1 Connect a network cable between the PC network port and the WAN_1 port protected by a security mechanism on the ECC800 Pro Table 5 7 Default IP addresses for the WAN and LAN ports on the ECC800 Pro Port De...

Page 280: ...If the WAN_1 port IP address is 192 168 8 10 subnet mask is 255 255 255 0 and default gateway is 192 168 8 1 set the PC IP address to 192 168 8 12 subnet mask to 255 255 255 0 and default gateway to 192 168 8 1 Step 3 Set LAN parameters NOTE If the ECC800 Pro connects to a LAN and a proxy server has been selected perform Step 3 3 and Step 3 4 If the ECC800 Pro connects to the Internet and the PC i...

Page 281: ...ibility View and add the web access address to the compatibility view 2 Choose Tools Internet Options Security and add the ECC800 Pro access address to the list of trusted sites Figure 5 10 Adding an address 3 Enable file download and set the security level of the trusted site to low FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei T...

Page 282: ...ick Delete 3 In the Delete Browsing History dialog box select all options except Password and click Delete Step 5 Log in to the ECC800 Pro WebUI 1 Enter https monitoring IP address such as monitoring IP address https 192 168 8 10 in the address box of the browser and then press Enter to enter the WebUI login page Figure 5 12 WebUI login page 2 On the login page enter the preset user name admin and...

Page 283: ...rating system is not flashed The mobile device has sufficient battery reserve You have obtained the IP address of the ECC800 Pro as well as the user name and password used for WebUI login A PC with an IP address in the same network segment as that of the ECC800 Pro is prepared and the PC has connected to port WAN1 on the ECC800 Pro Procedure Step 1 Download and obtain the app installation package ...

Page 284: ...angeme after the WiFi function is enabled The password is valid only after you hold down the button for the first time to enable the WiFi function If you enable the WiFi function on the WebUI there is no preset password After the WiFi function is enabled the password for a mobile phone to connect to the WiFi network is Changeme When you log in to the app using a pad the system prompts you to chang...

Page 285: ...t login change the password in time to ensure system access security When the mobile phone app connects to the monitoring system the WiFi function of the monitoring system is disabled by default Before connecting the mobile phone app to the monitoring system enable the WiFi function on the WebUI For security you are advised to disable the WiFi function when the app is not in use A password that ha...

Page 286: ...1 Download and obtain the app installation package Log in to Huawei AppGallery https a vmall com search for Service Expert and tap Download to obtain the installation package a Open the browser on the pad enter www baidu com in the address box search for Huawei AppGallery select Ordinary Download and tap Save b Install the Huawei AppGallery If the downloaded file exists in the drop down list box t...

Page 287: ...e page is changed from Initial startup password authentication to Activated the startup password authentication is complete NOTE After the first login change the password in time to ensure system access security When the mobile phone app connects to the monitoring system the WiFi function of the monitoring system is disabled by default Before connecting the mobile phone app to the monitoring syste...

Page 288: ...vice End 5 3 6 Creating a Smart Module Plan View Procedure Step 1 Choose Home Plan View create a micro module in Micro Module View and set the layout and device quantity based on the actual micro module scenario Step 2 Drag the icons of registered devices and devices on the cabinet list to appropriate positions in the layout to create a micro module plan view End 5 3 7 Adding a UPS2000G Prerequisi...

Page 289: ...In this example Device Address is set to 1 During actual configuration set the device address for the UPS2000G L based on the actual situation 3 Click Test Connect to check whether the UPS2000G L connects to the ECC800 Pro properly If the connection succeeds click Confirm The connected devices are displayed in the Number of connected devices list If the connection fails check whether the device is...

Page 290: ...it 7 Confirm that Smoke sensor type is automatically identified as Smoke sensor or Smoke sensor NC 8 Click Unhide All Advanced Signals then click Power Supply Parameters Ensure that I power supply enable AIDI_2 COM1 AIDI_4 COM3 is Enable Step 2 Check the monitoring functions of smoke sensor Table 5 9 Function check Check Method Normal Connection Status Alarm Clearance Method Simulate a smoky envir...

Page 291: ...N indicates 1 and OFF indicates 0 The address range is 1 to 4 Figure 5 14 DIP switch definitions for T H sensors NOTE The numbers 1 4 indicate the DIP switch settings of the T H sensors Table 5 10 DIP switch settings for T H sensors T H Sensor Address Toggl e Switc h 1 Toggl e Switc h 2 Toggl e Switc h 3 Toggl e Switc h 4 Toggl e Switc h 5 Toggl e Switc h 6 Toggl e Switc h 7 Toggl e Switc h 8 1 ON...

Page 292: ... The connected devices are displayed in the Number of connected devices list If the connection is abnormal check whether the device is properly connected to the ECC800 Pro whether the device and the ECC800 Pro are running properly and whether the parameter settings are consistent with the device parameters Step 3 Check functions of the T H sensor Table 5 12 Function check Check Method Normal Conne...

Page 293: ...has been connected to the RJ45 port on the WLDS900 water sensor and the other end has been connected to the AI DI_3 port on the ECC800 Pro Context To use the AI DI sensor enable the corresponding AI DI port and name the sensor The specific alarm then can be reported If the sensor is prefabricated only check its settings The actual value prevails Only the method of the parameter settings is describ...

Page 294: ...Commissioning Cabinet Electronic Clasp Locks When the system type is FusionModule800 and the cabinet electronic clasp locks are installed perform the following steps to configure it Prerequisites The cabinet electronic clasp locks of odd and even numbered cabinets have been cascaded in hand in hand mode respectively One end of a network cable is connected to the RS485_IN port on the first cabinet ...

Page 295: ...tronic clasp locks can be connected in series The cabinet electronic clasp locks of even numbered cabinets are connected in series The addresses start from 1 and a maximum of 12 cabinet electronic clasp locks can be connected in series Set a device address for a cabinet electronic clasp lock by operating the toggle switch on the cabinet electronic clasp lock Toggle switches 1 to 6 specify the devi...

Page 296: ...em Settings Device Management and click Add Device The parameters for adding devices are displayed Device attribute Elock Device type E LOCK Connect to ECC800 Pro Communicat ions port Odd numbered cabinets COM2 Even numbered cabinets COM3 Device address Enter the actual device address of the cabinet electronic clasp lock 4 Click Test Connect to check whether the connection between the cabinet elec...

Page 297: ...oor from the Cabinet door control drop down list box and click Submit to remotely open the door Open cabinet electroni c clasp locks in batches Choose Monitoring Cabinet click the Controls tab Select Open front door Open back door or Open all doors from the Open the door drop down list box select the setting and click Submit The cabinet electronic clasp locks unlock the doors in batches based on t...

Page 298: ...erference between the lock tongue and the cabinet post If they interfere with each other adjust the installation position of the lock tongue FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 286 ...

Page 299: ...e between the castors and the door sill at the bottom of the cabinet If they interfere with each other remove the fastener that secures the castors FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 287 ...

Page 300: ...d Information about a maximum of 20 users who will receive alarm notification can be displayed Prerequisites To implement alarm notification by SMS the following conditions must be met The ECC800 Pro is configured with a 4G module and supports standard SIM card access The ECC800 Pro is connected to a network with an email server through a WAN port Both the Internet and local area network LAN are s...

Page 301: ...ails to be sent check the outbox settings and DNS Server Address If the email is sent successfully click Submit NOTICE If Test email sending failed is displayed check whether the receiver s email server requires CA certificate verification If it is required download the CA certificate from the receiver s email website and upload it in the Mailbox Certificate area Figure 5 19 Email setting page NOT...

Page 302: ... QQ Mail If the email type is not in the list set parameters by referring to the help information of the email type 163 Mail smtp 163 com Non encryption 25 SSL encryption 465 126 Mail smtp 126 com Non encryption 25 SSL encryption 465 QQ Mail smtp QQ co m SSL encryption 465 Sohu Mail smtp sohu c om Non encryption 25 139 Mail smtp 139 com Non encryption 25 Hotmail smtp mail outloo k com TLS encrypti...

Page 303: ...x parameters for receiving emails are correctly set Step 4 Add a mobile number to receive event notifications NOTE The mobile phone number is used only for configuring the SMS function and is not used for other purposes The phone number is encrypted during transmission in the ECC800 Pro to ensure that the personal data of users is fully protected FusionModule800 Smart Small Data Center User Manual...

Page 304: ...navailable Failed to send the test short message is displayed Check whether the mobile phone number is correctly set Step 5 Set the alarm notification delay parameter and the new alarm notification parameter Figure 5 22 Setting the alarm notification parameters FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 292 ...

Page 305: ...e email parameter settings click Modify or Delete 5 3 11 Video Management 5 3 11 1 Reference Documentation Before commissioning a camera prepare the following documents in addition to this document Table 5 19 Commissioning documents Component Document C3220 Huawei C Series SDC 8 0 1 Product Documentation VCN510 VCN520 VCN540 VCN510 VCN520 VCN540 Product Documentation IVS1800 IVS1800 8 1 0 Product ...

Page 306: ...00 Pro avoid high data traffic such as the concurrent display of dynamic monitoring of cameras and VCN or IVS1800 video playback To ensure the normal operating of ECC800 Pro services you can view video from a maximum of two cameras concurrently LAN Switch Networking Scenario If there are multiple VCNs or IVS1800s for multiple smart modules you are advised to evenly distribute the cameras to each V...

Page 307: ...ernet Explorer 10 11 Chrome 38 FireFox 35 51 Supports Windows 8 Internet Explorer 10 11 Chrome 38 FireFox 35 51 Supports Windows 10 Internet Explorer 11 Chrome 38 FireFox 35 51 The Internet Explorer tab plugin needs to be installed for Google Chrome 45 and later versions Only 32 bit browsers are supported 2 Enter the preset user name admin and the preset password HuaWei123 and click Log In NOTE Yo...

Page 308: ...S 1 2 NOTE You must enable TLS 1 1 or TLS 1 2 when the HTTPS protocol is used to access the camera Otherwise the camera WebUI cannot be opened 1 Choose Tools Internet Options The Internet Options dialog box is displayed 2 Click the Advanced tab 3 Select Use TLS 1 1 or Use TLS 1 2 4 Click OK Set Use Pop up Blocker to Disable 1 Choose Tools Internet Options The Internet Options dialog box is display...

Page 309: ...address Camera IP address This parameter is available only when IPv4 address assignment is set to Use the following IP address Enter the planned IP address for example 192 168 1 161 IP addresses starting with 127 are invalid You must enter an IP address starting with a value that ranges from 1 to 223 IPv4 gateway Gateway IP address of the network where the camera is located The default value is 19...

Page 310: ...and set the parameters as shown in the following figures Figure 5 27 Setting primary stream parameters Figure 5 28 Setting secondary stream 1 parameters FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 298 ...

Page 311: ...ncoding process of each slice is independent of each other Therefore the camera can encode and decode multiple slices in parallel improving encoding and decoding performance This parameter is selected by default Encoding protocol Set the coding protocol based on the site requirements The options are as follows H 264 The H 264 protocol requires relatively small bandwidth to ensure video quality MJP...

Page 312: ...t rate The bit rate range depends on the selected resolution Bit rate value Average bit rate when Bit rate type is set to Constant bit rate The bit rate range depends on the selected resolution Bit rate control mode This parameter is available only when you set Bit rate type to Constant bit rate The options are as follows Frame rate priority Ensure the smoothness of the video image Image quality p...

Page 313: ...onfigured Context If the VCN or IVS1800 is not configured and an SD card is chosen perform the following procedure Procedure Step 1 Log in to the Huawei camera WebUI 1 Configure the PC IP address and the camera IP address in the same network segment Enter the camera IP address 192 168 0 120 by default in the address bar of the Internet Explorer and press Enter 2 Enter the preset user name admin an...

Page 314: ...ge Management page is displayed Format the SD card 4 Set the camera stream type and primary stream parameters Path Settings Video Audio Image Video Settings Figure 5 30 Setting audio and video parameters FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 302 ...

Page 315: ...1 Mbit s 66 H 265 720P 25 50 0 8 Mbit s 75 H 264 720P 25 50 1 Mbit s 66 H 265 720P 25 50 0 6 Mbit s 105 H 264 720P 25 50 0 8 Mbit s 75 5 Choose Settings Intelligent Analysis Common Intelligence Select Enable click Add add motion detection areas set motion detection parameters and click Save 6 Set the deployment policy Figure 5 31 Setting the deployment policy 7 Set the alarm linkage policy FusionM...

Page 316: ...ext Before commissioning the C3220 camera set the IP address for the C3220 camera based on customer requirements Configure the internal IP addresses of the camera and VCN or IVS1800 and the IP address of the LAN port on the ECC800 Pro in the same network segment Configure the external IP addresses of the camera and VCN or IVS1800 and the IP address of the WAN_1 port on the ECC800 Pro in the same n...

Page 317: ... the ECC800 Pro 2 Use a network cable to connect the PC to the PoE port on the smart ETH gateway Then set the local IP address of the PC to 192 168 0 11 3 Remove the camera shell and press the reset button for 6s to 10s to restart the camera Figure 5 33 Reset button 4 Open a web browser enter https 192 168 0 120 in the address box and press Enter Enter the default user name admin and preset passwo...

Page 318: ...gs Internet Zone dialog box is displayed 5 Set Automatic prompting for ActiveX controls to Enable and set Download unsigned ActiveX controls and Initialize and script ActiveX controls not marked as safe for scripting to Prompt 6 Click OK Enable TLS 1 1 or TLS 1 2 NOTE You must enable TLS 1 1 or TLS 1 2 when the HTTPS protocol is used to access the camera Otherwise the camera WebUI cannot be opened...

Page 319: ...work Time Second Protocol Parameters and select Enable ONVIF Figure 5 34 ONVIF parameters 6 Remove the network cable from the PC to the PoE port on the ETH gateway 7 Connect the PC to the LAN1 port on the ECC800 Pro using a network cable and reconnect the network cable between the smart ETH gateway and the LAN2 port on the ECC800 Pro Step 2 Set the IP address for the C3220 camera FusionModule800 S...

Page 320: ...lick Log In Figure 5 35 Clicking the camera access link 5 Choose Settings Network TCP IP set Way to obtain IPv4 to Use the following IP address and set an IP address to the planned IP address for the camera The IP address should be in the range of 192 168 248 50 to 192 168 248 199 Step 3 On the ECC800 Pro WebUI click Add under Video Information In the New Video Information dialog box that is displ...

Page 321: ...gure 5 38 Password for accessing the IP camera ONVIF interface Step 4 After entering the video information click Confirm Step 5 In the Video Information list click the link under the Link column and go to the camera WebUI as prompted Step 6 For details about how to commission the camera and set parameters see the documents delivered with the device or the documents obtained by referring to the Pre...

Page 322: ...secondary stream 1 parameters as shown in the following figures NOTICE Set the encoding protocol to H 265 Figure 5 39 Setting primary stream parameters FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 310 ...

Page 323: ...p 1 Log in to the Huawei camera WebUI Step 2 Format the SD card 1 Choose Settings System Configuration Storage Management 2 The Storage Management page is displayed Format the SD card Step 3 Set the camera stream type and primary stream parameters Path Settings Video Audio Image Video Settings FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyrigh...

Page 324: ...deo Storage Duration h H 265 1080P 25 50 1 Mbit s 66 H 264 1080P 25 50 1 Mbit s 66 H 265 720P 25 50 0 8 Mbit s 75 H 264 720P 25 50 1 Mbit s 66 H 265 720P 25 50 0 6 Mbit s 105 H 264 720P 25 50 0 8 Mbit s 75 Step 4 Choose Settings Intelligent Analysis Common Intelligence Select Enable click Add add motion detection areas set motion detection parameters and click Save FusionModule800 Smart Small Data...

Page 325: ...the PC in the same network segment as the IP address of the VCN The version number is subject to the Quick Start delivered with the VCN Procedure Step 1 Enter the OMU portal address the default address for VCN500 is https 192 168 1 100 8443 the default address for VCN510 VCN520 VCN540 is https 192 168 2 101 8443 in the address bar of the Internet Explorer and press Enter NOTE The OMU portal suppor...

Page 326: ...N510 8 rear view Figure 5 45 VCN510 16P rear view If the device is not VCN510 and the software version is V100R003 or later the default user name is admin If the software version is V100R002 or earlier the default user name is Admin End 5 3 11 5 2 Initializing VCN510 Disks Context When the VCN510 is delivered to the site recording data can be stored only after you install and initialize the disks ...

Page 327: ...of disks that work independently NON RAID If disks work independently recording data is stored into two disks in sequence ensuring high disk usage However the data storage reliability of disks that work independently is lower than that of RAID 1 Step 5 Click Start A risk warning is displayed Step 6 Click OK The system starts to initialize the disks NOTE The server will be restarted during the init...

Page 328: ...one disk is synchronizing data in the system partition to the system partition of another disk The synchronization process takes about 20 hours which does not impact services During this process do not remove and insert disks If the OMU portal stays at the Local Disk tab page even if users do not perform any operation for a long period of time the OMU portal will not automatically return to the lo...

Page 329: ...ing to the site requirements Figure 5 50 Configuring the server NOTE Set Business IP to XXX XXX XXX XXX Subnet mask to 255 255 255 0 and Gateway IP to XXX XXX XXX XXX The values here are examples The actual value prevails The VCN automatically restarts after the IP address is modified The restart takes about 5 minutes After the restart use the new IP address to access the VCN 3 Modify the IP addre...

Page 330: ...rPort delete the parameter value 0 from Value leave the value empty and click Save Figure 5 51 Setting the NAT port number for the MU 7 In the search result click Edit in the row where the value of Parameter Name is NatIP and set Value to the external IP address of the VCN Click Save Figure 5 52 Setting the external IP address of the MU NOTE Set NatIP to the external IP address of the VCN which is...

Page 331: ...ing camera NTP synchronization 4 In the search results click Edit in the row where Parameter Name is NTPIPC and set Value to 1 5 Click Save After the camera NTP synchronization function is enabled the camera after being connected to the server will automatically synchronize time with the server End Follow up Procedure Optional Set up a VCN stack For details log in to the https e huawei com search ...

Page 332: ... Software Download tab click the version and patch number corresponding to the current version and download the Client Package zip software package Figure 5 55 Client Package search result 2 Right click HW_IVS_Client exe and choose Run as administrator from the shortcut menu Use the default installation mode until the installation is complete 3 Right click the client program and choose Run as admi...

Page 333: ...eed to access NOTE If there are multiple VCNs for multiple smart modules you are advised to evenly distribute the cameras to each VCN 3 Click Search in each camera record enter the user name and password in the text boxes and click Verify If the camera is verified successfully select cameras to add and click Next 4 Preview live video images click the camera in the camera list on the left and adjus...

Page 334: ...u can select Enable account validity period and set Valid from and Valid to to set the account validity period for the created user Figure 5 56 Creating a user 3 Set Multi point logins to a value greater than 2 4 In the Assign Device View Rights area select the cameras to be browsed and queried by the user Set other parameters based on the documentation delivered with the equipment or the document...

Page 335: ...dress indicates the IP address of the IVS1800 The default IP address is 192 168 3 111 NOTE The OMU portal supports Internet Explorer 10 0 and later versions Step 2 Log in to the OMU portal Set the service system and operating system passwords at the first login 1 Setting the password for the admin user of the service system 2 Setting the password for the admin user of the operating system 3 Settin...

Page 336: ...requirements Figure 5 59 Configuring the server Single Mode by default NOTE Set Business IP to XXX XXX XXX XXX Subnet mask to 255 255 255 0 and Gateway IP to XXX XXX XXX XXX The values here are examples The actual value prevails 2 Change the PC IP address to an address in the network segment of the new IVS1800 IP address enter the IVS1800 IP address in the address box of the Internet browser and l...

Page 337: ...ow where the value of Parameter Name is MUNNatIP and set Value to the external IP address of the IVS1800 Click Save Figure 5 60 Setting the external IP address of the MU NOTE Set MUNNatIP to the external IP address of the IVS1800 which is the same as the external IP address mapped by the IVS1800 on the ECC800 Pro 6 Set Module Name to OMU and click Search 7 In the search result click Edit in the ro...

Page 338: ... Figure 5 62 Configuring camera NTP synchronization Step 6 Create a user When connecting to the IVS1800 on the NetEco you need to log in to the VCN as a non admin user 1 Log in to the OMU portal as the admin user 2 Choose User Management Add User NOTE When creating a user you can select Enable account validity period and set Valid from and Valid to to set the account validity period for the create...

Page 339: ...rt huawei com enterprise and search for and choose iClient In the search result click the Software Download tab click the version and patch number corresponding to the current version and download the software package as required Figure 5 63 iClient software package search result 2 Decompress the software package double click the installation program and complete the installation as prompted 3 Rig...

Page 340: ...hen the IVS1800 is added to the iClient by the admin user the iClient checks whether the login password of the admin user has been set If the password is not set log in to the OMU portal to set the password 6 Click Finish to go to the iClient Step 2 Add a camera For details see the documentation delivered with the device or obtain the documentation by referring to the Reference Documentation secti...

Page 341: ...e Camera Access Figure 5 66 Camera Access 3 Select Auto Batch Access and click Start 4 Set the IP address segment Figure 5 67 Setting an IP network segment FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 329 ...

Page 342: ...are multiple IVS1800s for multiple smart modules you are advised to evenly distribute the cameras to each IVS1800 6 Select the cameras to be added and click Next 7 Click Finish 8 Preview live video On the iClient home page click Live and drag a camera to the live video pane If the live video can be properly played the camera is successfully connected Step 3 Configure a recording policy 1 Select Lo...

Page 343: ... 1 Select Local mode to log in to the iClient On the home page click Device Management 2 Right click an IVS1800 and choose Storage Management 3 Click the Server Recording Plan tab The tab page for configuring a server recording plan is displayed FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 331 ...

Page 344: ...ained the IP address of the ECC800 Pro as well as the user name and password used for WebUI login A PC with an IP address in the same network segment as that of the ECC800 Pro is prepared and the PC has connected to port WAN_1 on the ECC800 Pro Ensure that Enable linkage control function is Yes FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyrig...

Page 345: ...00 Pro reports a critical alarm to remind the customer to close the door manually The alarm is cleared after the door is closed NOTE After the IT cabinet door automatically opens a door open alarm is displayed on the active alarms page of the ECC800 Pro In the Linkage Group area click Link emergency ventilation with cabinet electronic clasp lock open Click to expand the Linkage Logic List Click in...

Page 346: ...in to the ECC800 Pro WebUI as an administrator Step 2 Choose System Settings Linkage Control Step 3 Ensure that Enable linkage control function is Yes Step 4 On the Linkage Group tab page set Link emergency ventilation with clasp lock open to on NOTE Select Link emergency ventilation with clasp lock open under Linkage Group If its value is on the corresponding logic configurations under Linkage Lo...

Page 347: ...new signal name of AI DI_1 to Smoke and click Submit Step 6 Enable the AI DI device 1 Choose Monitoring System ECC800 Running Parameters AI DI_1 Port Settings 2 Set Smoke sensor to Enable and click Submit 3 Confirm that Smoke sensor type is automatically identified as Smoke sensor or Smoke sensor NC 4 Click Unhide All Advanced Signals and click Power Supply Parameters Ensure that III power supply ...

Page 348: ...al name of AI DI_2 to Fire and click Submit Step 6 Enable the AI DI device 1 Choose Monitoring System ECC800 Running Parameters AI DI_2 Port Settings 2 Set Fire sensor to Enable Click Submit to access the AI DI_2 setting page 3 Select Fire sensor type and set it to Normal Open or Normal Close as required 4 Click Unhide All Advanced Signals and click Power Supply Parameters Ensure that I power supp...

Page 349: ...ettings System Parameter s Monitor IP WAN_1 IP address 192 168 8 1 0 Set this parameter based on the IP address assigned by the network administrator Subnet mask 255 255 25 5 0 Set this parameter based on the subnet mask assigned by the network administrator Default gateway 192 168 8 1 Set this parameter based on the default gateway address assigned by the network administrator Step 3 Click Submit...

Page 350: ...em Settings NMS Application NetEco Set Authenticati on Password Authenticatio n password Modifyme _123 Set this parameter based on customer requirements NOTE Requirements for setting passwords a z A Z 0 9 _ 8 32 characters that include at least three of the following types lowercase letters uppercase letters digits and special characters Confirm authenticatio n password Step 5 Click Submit End 5 3...

Page 351: ...er Procedure Step 1 Ensure that the power cables and ground cables are securely connected with correct polarity and good contact Step 2 Ensure that the input power supply of the PDB is off Use a multimeter to test the resistance between the power outputs of the PDF and between the working ground and protective ground It is required that short circuit not occur between power outputs or between the ...

Page 352: ...nging If the number of online users reaches the maximum number supported by the system a message is displayed indicating that you cannot log in In this case contact the system administrator After you enter the incorrect password for three consecutive times you must enter the verification code upon the fourth login After you enter the incorrect password for five consecutive times the user account o...

Page 353: ...com b Obtain iManager NetEco 6000 V600R021C00SPCXXX ReleaseDoc_ENG zip NetEco6000_V600R021C00SPCXXX_Adapters zip and NetEco6000_V600R021C00SPCXXX_DomainAdapters zip from Support Product Support Carrier Cloud Data Center Data Center Facility Fusion Modular Data Center iManager NetEco 6000 Decompress the files and locate the adapter software installation packages in the NetEco6000_V600R021C00SPCXXX_...

Page 354: ...an create DDF Battery Cabinet Rack Modular Power Cabinet Fire Protection Cabinet and Rack Custom under Room You can create Container and Container ShapeNode under ContainerDC You can create Modular Park NetecoSite FusionModule500 and under Subnet You can create DDF Battery Cabinet Rack Modular Power Cabinet and Fire Protection Cabinet and Rack Custom under NetecoSite You can create DDF Battery Cab...

Page 355: ...ck on the toolbar Repeat steps Step 2 1 to Step 2 4 until the configuration is complete Step 3 Click on the toolbar End 5 3 13 1 9 Adding a Smart Module This section describes how to create a smart module in the root node subnet equipment room container or site management domain Prerequisites You have logged in to the NetEco client using a web browser You have created management domains in Data Ce...

Page 356: ...ent Info of the smart module or retain the default values and then click NOTICE The parameters with are mandatory End Follow up Procedure Perform the following operations in the Data Center Planning page as required FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 344 ...

Page 357: ...u delete subdevices in the module Delete one smart module 1 Select Modular and click Delete under as shown in Figure 5 76 Figure 5 76 Deleting one smart module 2 In the displayed Confirm dialog box click Yes Delete multiple smart modules in batches 1 Click on the toolbar to display the Figure 5 77 page FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05...

Page 358: ...u Need To Then Figure 5 77 Deleting multiple smart modules in batches FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 346 ...

Page 359: ...added you can set attributes for the component in the Component Info list in the right pane The system automatically displays values for Parent Name and Control Type and you do not need to manually set them you only need to set Name 4 In the upper area of the current page click 5 3 13 1 10 Creating an ECC800 Pro on the NetEco Prerequisites You have logged in to the NetEco client using a web browse...

Page 360: ... Adding an ECC800 Pro device to the smart module NOTE Click OK and you can view the task information including Type Device Name Region Progress Status Start Time End Time and Information in the displayed Progress window 5 3 13 2 CloudOpera NetEco Management 5 3 13 2 1 Logging In to the EDCM Using a Web Client Prerequisites You have obtained a valid user name and password You have created a free tr...

Page 361: ...umber of online users reaches the maximum number supported by the system a message is displayed indicating that you cannot log in In this case contact the system administrator After you enter the incorrect password for three consecutive times you must enter the verification code upon the fourth login After you enter the incorrect password for five consecutive times the user account or the IP addre...

Page 362: ...named Procedure Step 1 Import the obtained digital certificate to the cer directory of the EDCM folder on the mobile client Step 2 On the mobile client tap the icon of the EDCM app The login screen of the app is displayed Step 3 Tap to access the Settings screen Step 4 Tap Replace the certificate to access the Cert Change screen Step 5 Select the new certificate and tap Yes in the displayed dialog...

Page 363: ...or three consecutive times the system automatically displays Verification code Step 3 Tap Log In NOTE If no data is displayed on the screen or a message indicating a network error is displayed check whether the mobile device has properly connected to a WiFi or mobile network If the network is normal check whether you have been forcibly logged out on the NetEco End 5 3 13 2 6 Setting EDCM Communica...

Page 364: ...gs NMS Application Step 4 Select the NetEco tab In the Communication Parameters area set parameters such as NetEco Deployment Location Server IP and Port Number and click Submit Table 5 33 EDCM parameters Parameter Setting NetEco Location Local Server IP Specifies the IP address of the EDCM server NOTE The IP address of the EDCM server must be on the same network as the IP address of the ECC800 Pr...

Page 365: ... of the network ESN ESN of the ECC controller NOTE Tap to scan the QR code on the ECC controller to obtain the ESN Longitude Longitude of the network You can manually enter the value or use GPS to locate Latitude Latitude of the network You can manually enter the value or use GPS to locate Customer Information Customer information FusionModule800 Smart Small Data Center User Manual 5 Power On Comm...

Page 366: ...Parameter Description Address Address of the network End FusionModule800 Smart Small Data Center User Manual 5 Power On Commissioning Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 354 ...

Page 367: ...ments Otherwise the UPSs may fail to operate properly and the lifespan may be shortened For details about how to upgrade the software version visit https support huawei com carrier docview nid DOC1100723472 to download the upgrade guide 6 1 1 Monthly Maintenance Table 6 1 Monthly preventive maintenance table Maintenance Item Operation Expected Result Troubleshooting Power indicator Observe the ind...

Page 368: ... LCD all units are operating properly No fault or alarm information is found in the active and historical alarm records If an alarm is present rectify the fault by checking the device status and parameters ECC800 Pro AC input Input voltage 200 240 V AC Frequency 45 55 Hz If the input voltage is abnormal check the power grid and input cable connection Output voltage Output voltage 53 5 V DC 5 If th...

Page 369: ...heck the network cable connection Monitor interface network management system or WebUI Export smart cooling product logs alarms temperature humidity as well as the operating status and time of the water sensor door status sensor temperature sensor and smoke sensor from the management system View the historical alarms generated in this month and select the most common five ones If an alarm is gener...

Page 370: ...s generated If there is no alarm replace the water detection cable Smart cooling product Condensate water pan and liquid level detector Check that the condensate water pan and liquid level detector have no scale Clean up the scale from the condensate water pan and liquid level detector Evaporator Check that no foreign matter exists on the evaporator surface Remove foreign matter Indoor fan Check t...

Page 371: ...leshooting UPS Cleanliness When the cabinet surface is wiped using white paper the paper does not turn black Remove the dust especially from the air filter on the front door or replace the air filter Parameters The configuration of the output voltage grade frequency number of batteries and battery capacity meets requirements Reset the parameters Power cables and terminals between the UPS and the p...

Page 372: ...n insulation tester The insulation resistance is greater than or equal to 5 megohms If the cable insulation performance is poor replace the cable Insulation performance of the power distribution subrack Measure the insulation resistance using an insulation tester The insulation resistance is greater than or equal to 10 megohms If the insulation performance is poor check and maintain the components...

Page 373: ...normal contact Huawei technical support Battery operating temperature 1 The ambient battery temperature is 25 5 C 2 The battery operating temperature is lower than 45 C 3 Battery charge and discharge conditions meet the requirements specified in the battery specifications 1 Identify the cause of an abnormal battery operating temperature 2 If the fault persists contact Huawei technical support Fusi...

Page 374: ...k whether the equalized charging voltage and float charging voltage are correctly set for the UPS 3 If the fault persists contact Huawei technical support Battery management parameter settings Check that the settings of battery management parameters meet the requirements in the user manual Set parameters correctly Battery bolts The location of the signs marked on battery terminal bolts indicating ...

Page 375: ...ists contact Huawei technical support Shallow discharge test recommended Conduct a shallow discharge test when the UPS is backed up to verify that the batteries can discharge properly 1 Locate the cause when an exception is identified 2 If the fault persists contact Huawei technical support Capacity test recommended When the UPS is backed up discharge a battery to the undervoltage alarm threshold ...

Page 376: ...tery manufacturer After checking that the battery screws meet the requirements mark the screws for later check 1 Rectify any abnormal connection 2 If the fault persists contact Huawei technical support Glass door steel glass cleaning Use a soft cotton cloth to clean the glass Clean the glass with clean water Do not use any organic solvent such as alcohol thinner or glass cleaner To avoid scratchin...

Page 377: ...s work properly Replace abnormal fuses Check that the cable connection is secure and correct Secure loose cables Check that the electrical components and control components of the indoor unit are free of dust Perform the operation with the power off Use a brush or compressed dry air to remove dust from electrical components control components and voltage detection boards Check that the electrical ...

Page 378: ...nit is secured to the floor Tighten the screws that secure the rack to the floor Check that the fan runs properly without abnormal noise or vibration and the blades rotate properly Replace the outdoor unit by following instructions in 6 4 3 2 1 Replacing an Outdoor Fan Check that the fan air intake and exhaust vents are not blocked Clear obstacles 6 2 Troubleshooting 6 2 1 Power Supply and Distrib...

Page 379: ... the switch again and check whether the system is overloaded Restart the UPS If the UPS is faulty replace it The surge protection function fails The SPD circuit breaker is OFF The SPD ground cable is not connected The surge protection module is abnormal The SPD window is red Check that the SPD circuit breaker is turned on The power distribution subrack monitoring type will prompt an alarm indicati...

Page 380: ...y mode The UPS mains switch is OFF Turn on the UPS mains switch The input cable is not properly connected Check the UPS input power cable connection The UPS fails to communicate The UPS communications cable is not properly connected The UPS parallel cable is not properly connected The UPS is deleted on the ECC800 Pro WebUI Reconnect the UPS communications cable Reconnect the UPS parallel cable Rem...

Page 381: ...es 1 second and then stops 1 second The battery reserve is insufficient The UPS is about to shut down The UPS will soon shut down due to insufficient battery reserve and loads will be powered off The number of batteries and battery capacity are incorrectly set Save load data immediately and shut down primary loads to avoid data loss or damage Connect the UPS input to the backup AC power supply imm...

Page 382: ...umpers may affect control functions and damage equipment Table 6 5 Troubleshooting Cat eg ory Sympt om Possible Cause Measure Ind oor uni t The indoor unit fails to start The indoor fan is damaged Replace the indoor fan by following instructions in 6 4 3 1 1 Replacing an Indoor Fan The connection terminals for the fans are not securely connected Secure the connection terminals Water overflo ws The...

Page 383: ...humidifiers Ou tdo or uni t Abnor mal noise is generat ed during operati on The compressor fan or pipes are loose Check and secure loose parts The compre ssor does not work The high and low pressure switches are triggered Check the high and low pressure switches The circuit breaker fuse or cable is disconnected Check the main circuit breaker fuses and cables The compressor motor is damaged Check w...

Page 384: ...e refrigerant The outdoor fan speed controller fails Replace the fan speed controller The refrigerant leaks Apply soapy water or use a halogen leak detector to check for any leakage If leaking points are found retrieve the refrigerant and weld the leaking points again Contact Huawei technical support The outdoor temperature is too low No action is required The compre ssor suction pressur e is too ...

Page 385: ... n that the compre ssor generat es much noise when it shuts down Liquid is returning to the compressor Check whether the oil temperature and discharge temperature are within the normal range 70 100 C Refrigerant oil is insufficient Add refrigerant oil 6 2 3 Management System Troubleshooting Table 6 6 Common faults and troubleshooting for PSUs Symptom Possible Cause Measure The Power indicator gree...

Page 386: ... on Output overvoltage protection If a single PSU is locked out disconnect the AC input from the PSU and then power on the PSU again after the indicator turns off If the fault persists replace the PSU If multiple PSUs are locked out remove all PSUs and reinstall them one by one to locate the faulty ones Then replace faulty PSUs No output due to a PSU fault Replace the faulty PSU Table 6 7 Common f...

Page 387: ... short circuit 3 The ALM indicator red is steady on Faults and alarms are generated View active alarms on the WebUI and clear them one by one 6 3 Alarm Reference NOTE This chapter provides only measures to clear major and critical alarms for certain components For details about other alarms see the ECC800 Pro WebUI Table 6 8 Alarm list Component Alarm Name Alarm Severit y Possible Cause Measures S...

Page 388: ...tches the output system Fan fault Critical The fan is abnormal Clean up foreign matter around the fan If the fault persists contact Huawei technical support Inverter fault Critical The inverter output short circuits Eliminate the short circuit at the output port cable connection and then power on and start the inverter again If the fault persists contact Huawei technical support Output short circu...

Page 389: ...crews are tightened Check that battery terminals are properly connected to connectors Single Batt Exception Critical The battery shell is broken resulting in electrolyte and electricity leakage The battery loop cable is broken and short circuited to the ground resulting in electricity leakage Check whether the appearances of abnormal batteries are intact and replace abnormal batteries Check whethe...

Page 390: ... the smart cooling product and the smart socket or monitoring host 1 Set the DIP switch correctly for teamwork 2 Check the teamwork cables 3 Change the addresses of the smart cooling product units 4 Configure one smart cooling product unit as the master unit 5 Power on the master unit or configure another unit as the master unit 6 Maintain or replace the ETH converter 7 Maintain or replace the sma...

Page 391: ...e the smart socket 6 Maintain or replace the cables between the smart cooling product and the smart socket or monitoring host Power overvolt Major 1 The power supply voltage is high 2 The outdoor control board is faulty 1 Check the power supply voltage 2 Maintain or replace the outdoor control board Power undervolt Major 1 The power supply voltage is low 2 The outdoor control board is faulty 1 Che...

Page 392: ...he ambient temp is high 4 The supply air HT alarm threshold is inappropriate 5 The temp displayed is different from the actual temp 1 Add more smart cooling product units 2 Check other causes if the alarm persists after startup 3 Check the ambient temp 4 Adjust the supply air HT alarm threshold 5 Calibrate or replace the abnormal sensors Supply air LT Warnin g 1 The load is low 2 The ambient temp ...

Page 393: ...mp is higher than the return air HT alarm threshold during startup 3 The ambient temp is high 4 The return air HT alarm threshold is inappropriate 5 The temp displayed is different from the actual temp 1 Add more smart cooling product units 2 Check other causes if the alarm persists after startup 3 Check the ambient temp 4 Adjust the return air HT alarm threshold 5 Calibrate or replace the abnorma...

Page 394: ...mbient humidity is low 3 The low humidity alarm threshold is inappropriate 4 The humidity displayed is different from the actual humidity 1 Adjust the position of the T H sensors 2 Check the ambient humidity 3 Adjust the low humidity alarm threshold 4 Calibrate or replace the abnormal T H sensors Return air 1 temp invalid Major 1 The cables to the temp sensor are loose or damaged 2 The temp sensor...

Page 395: ...m the T H sensor 2 Maintain or replace the T H sensor Cold aisle humid invalid Major 1 Dirt or water exists around the T H sensor which leads to a detection fault 2 The T H sensor is faulty 1 Remove dirt or water from the T H sensor 2 Maintain or replace the T H sensor Ctrl point sensor disabled Major All the T H sensors of the control point are disabled Enable the T H sensors of the control point...

Page 396: ... 6 The EEV is faulty 1 Identify and repair the leaking point and refill refrigerant after maintenance 2 Clean the condenser fins 3 Check the ambient temp 4 Calibrate or replace the discharge temperature sensor 5 Maintain or replace outdoor fans 6 Maintain or replace EEV Comp discharge HT lock Critical The comp discharge HT alarm is generated frequently Reference to the solutions for the comp disch...

Page 397: ...2 Check the signal cables to outdoor unit 3 Clean the condenser fins 4 Maintain or replace the outdoor fan drive or fan 5 Check cables to the high pressure switch 6 Maintain or replace the high pressure switch 7 Maintain or replace the EEV 8 Decrease certain amount of refrigerant 9 Reinstall the outdoor unit properly Comp HP switch lock Critical The comp HP alarm is generated frequently Reference ...

Page 398: ...aintain or replace the EEV 7 Decrease certain amount of refrigerant Comp discharge HP lock Critical 1 The outdoor unit input power has an open phase incorrect phase sequence or is unavailable 2 Signal cables to the outdoor unit are not properly connected 3 The condenser fins are blocked 4 The outdoor fan driver or fan is faulty 5 The discharge press displayed is different from the actual press 6 T...

Page 399: ...Check for any leakages Fill refrigerant after maintenance or replacement 2 Maintain or replace the solenoid coil or the solenoid valve 3 Check the cables to the press sensor 4 Calibrate or replace the press sensor 5 Maintain or replace the dryer filter 6 Maintain or replace the expansion valve 7 Maintain or replace the indoor fans 8 Check and confirm that stop valve has been opened Power off the i...

Page 400: ...mpressor drive For details about how to rectify the faults of the compressor drive follow the troubleshooting instructions Comp drive DC overvolt Major 1 The power supply voltage is high 2 The comp driver is faulty 3 The comp is faulty 1 Check the power supply voltage 2 Maintain or replace the comp driver 3 Maintain or replace the comp Comp drive DC undervolt Major 1 The power supply voltage is lo...

Page 401: ...for multiple times or the faulty lasts for a long time Maintain or replace the comp driver and clear the accumulated runtime Comp freeze point protection Major 1 The refrigerant leaks 2 The suction pressure sensor displayed is different from the actual pressure 3 The filter dryer is blocked 4 The expansion valve is blocked 1 Check for any leakages Fill refrigerant after maintenance or replacement ...

Page 402: ...ryer filter 6 Maintain or replace the expansion valve 7 Maintain or replace the indoor fans Comp LP switch lock Critical The comp suction LP alarm is generated frequently Reference to the solutions for the comp suction LP alarm Gas pipe temp sensor fault Major 1 Cables to the temperature sensor are not properly connected 2 The temperature sensor is faulty 1 Check cables to the temperature sensor 2...

Page 403: ...ed 2 Maintain or replace the comp driver 1 Check the cables to the comp driver 2 Maintain or replace the comp driver Outdoor unit main board fault Major Outdoor control board is faulty Maintain or replace the outdoor control board Outdoor unit pwr module fault Major Outdoor hardware is fault Maintain or replace the outdoor hardware Indoor fan fault Major 1 The power supply to the indoor fan is abn...

Page 404: ...jor 1 The water supply is insufficient 2 The humidifier float has dropped and is jammed 3 The humidifier float interconnection terminals are abnormal 4 The water inlet solenoid valve cannot open 5 Cables of the water inlet solenoid valve are not properly connected 1 Verify that water supply to the humidifier is normal 2 Verify that the humidifier float can float and drop properly 3 Verify that the...

Page 405: ...locked or bent 4 Clear the foreign matter in the water pan and filter Drain abnormal Major 1 The high liquid level sensor is faulty 2 The condensate water pump is faulty 3 The drainpipe is blocked 4 The drainage filter is blocked 1 Check the cables to the high liquid level sensor clear the obstacles or replace the high liquid level sensor 2 Check the cables to the condensate water pump clear the f...

Page 406: ...t failure Warnin g The power input cables of the PSU are loose or damaged Check the power input cables of the PSU PSU fault Major The PSU is faulty Maintain or replace the PSU PSU comm interrupt Major 1 The communication cables of the PSU are faulty 2 The PSU is faulty 3 The communication port of the control board is faulty 1 Check the communication cables of the PSU 2 Maintain or replace the PSU ...

Page 407: ...tronic expansion valve coil 2 Replace the electronic expansion valve coil 3 Replace the electronic expansion valve 4 Maintain or replace dehumid solenoid valve coil EEV high overheating degree Major 1 The electronic expansion valve coil is loose 2 The electronic expansion valve coil is faulty 3 The electronic expansion valve is faulty 1 Reinstall the electronic expansion valve coil 2 Replace the e...

Page 408: ...es to the electronic expansion valve driver 2 Replace the control board Outdoor fan communication failure Major 1 The indoor and outdoor communications cable is not properly connected 2 The outdoor fan driver is faulty 3 The outdoor unit is not powered on 4 The communication port of the control board is faulty 1 Check the indoor and outdoor communications cable 2 Maintain or replace the outdoor fa...

Page 409: ... radiation on the monitoring point resulting in high temperature 3 The temp displayed is different from the actual temp 1 Measure the ambient temperature 2 Install a sunshade 3 Calibrate or replace the abnormal sensors Outdoor fan drive locked Critical The outdoor fan fault alarm is generated repeatedly during a period of time See the measures for handling the outdoor fan fault alarm Outdoor fan f...

Page 410: ...incorrectly connected 2 Cond temp sensor is faulty 1 Check cables to the temperature sensor 2 Maintain or replace the temperature sensor 6 4 Parts Replacement 6 4 1 Replacing Structural System Components 6 4 1 1 Replacing a Cabinet Electronic Clasp Lock Prerequisites Tool Phillips screwdriver Material A spare cabinet electronic clasp lock is available and functional Context cabinet electronic clas...

Page 411: ...nic clasp lock are slotted holes If the door cannot be properly closed after installation adjust the lock height based on site requirements Step 5 Reconnect the cables to the cabinet electronic clasp lock End 6 4 1 2 Replacing a Gas Spring Prerequisites Tools Phillips screwdriver step ladder Material A spare gas spring is available and functional Context Gas springs are installed on the top of a c...

Page 412: ...the cabinet Step 2 Switch off the output circuit breaker of the power distribution subrack for the PDU2000 Disconnect the power cables and signal cables from the PDU2000 terminal block Step 3 Remove the bolts that secure the PDU2000 using a Phillips screwdriver Step 4 Secure the new PDU2000 to the rear door of the cabinet Step 5 Reconnect the power cables or signal cables to the PDU2000 and switch...

Page 413: ... component to be replaced are powered off after the component is powered off 6 4 2 1 Replacing a Surge Protection Module Prerequisites DANGER Do not replace a surge protection module during a thunderstorm Before replacing a surge protection module wear insulation gloves Tools insulation protective gloves electroprobe Material A new surge protection module of the same model is available and functio...

Page 414: ...During replacement do not touch the energized components in the power distribution subrack Figure 6 5 Replacing a surge protection module Step 5 Install the new surge protection module Step 6 Reinstall the protective panel for the SPD and switch the SPD circuit breaker to ON Step 7 Check whether there are alarms on the ECC800 Pro If there is no alarm the surge protection module is functional End F...

Page 415: ...n a similar way The following figure is for reference only Figure 6 6 Opening the fuse terminal block Step 2 Reinstall the fuse terminal block in the power distribution subrack Step 3 Close the fuse terminal block Step 4 Observe the indicator If the indicator is on the fuse is functional End 6 4 2 3 Replacing an Indicator Prerequisites Tools electroprobe insulation gloves Phillips screwdriver mult...

Page 416: ...g a Fuse Step 2 Optional Open the front door of the Converged Cabinet and remove the indicator protective panel Figure 6 7 Removing the indicator protective panel Step 3 Loosen the screw at the back of the indicator using a Phillips screwdriver and remove the cables NOTE When removing cables label the cables with corresponding terminal ports for later connection FusionModule800 Smart Small Data Ce...

Page 417: ...are UPS of the same model is available and functional The UPS is damaged or faulty and cannot work Scenario with One UPS Step 1 Ensure that the TN system is reliably grounded and that the main ground cable of the Smart Module is reliably connected NOTICE After removing cables wrap exposed terminals with insulation tape and do not block cable labels If cable labels are blocked cables may be connect...

Page 418: ...n the UPS and whether all cables are connected NOTICE Do not connect the manual bypass switch MBS signal cable to the UPS rear at present Step 9 Start the UPS When initialization is complete the setting wizard screen is displayed You can set the language the default language is English system parameters and battery parameters After you complete the settings press The standby screen is displayed St...

Page 419: ...ion tape Step 6 Remove screws from the UPS front panel and pull out the UPS Step 7 Install the new UPS and screw it to the cabinet Step 8 Connect the output power cables signal cable and UPS input power cables in sequence Check whether the cable labels are consistent with the silk screens on the UPS and whether all cables are connected Step 9 Start the UPS When initialization is complete the setti...

Page 420: ...d output power cables battery cables or battery pack cables and signal cables NOTICE Wrap the exposed cable with insulation tape Step 6 Remove screws from the UPS front panel and pull out the UPS Step 7 Install the new UPS and screw it to the cabinet Step 8 Connect the output power cables signal cables and UPS input power cables in sequence Check whether the cable labels are consistent with the si...

Page 421: ...y DC power source provide continuous power supply Replacement Requirements Conditions for the ESM to enter and exit the maintenance mode 1 The intelligent displacement lock function has been disabled When the intelligent displacement anti theft function is disabled hold down the MANUAL ON OFF button for at least 15s to enter the maintenance mode 2 Hold down the MANUAL ON OFF button for at least 15...

Page 422: ... is automatically activated and connects to the power system Step 6 Remove the protective gloves and pack up all tools End Follow up Procedure Put the removed component into the ESD box or bag and then place the ESD box or bag into the carton box with foams or the bag of the new component Fill in the fault card with the information about the removed component Contact your local Huawei office to ha...

Page 423: ...amaged or faulty and cannot work NOTICE Before replacing the ATS subrack ensure that the upstream power supply is disconnected Ensure that the power input is disconnected during replacement Procedure 1 Ensure that the upstream circuit breaker of the ATS is switched off 2 Remove the ATS input and output power cables and monitoring cables 3 Remove the faulty ATS subrack FusionModule800 Smart Small D...

Page 424: ...t power cables and monitoring cables 6 4 3 Replacing Cooling System Components 6 4 3 1 Replacing Indoor Unit Components Figure 6 11 and Figure 6 12 show the components of an indoor unit FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 412 ...

Page 425: ...id valve 3 High liquid level detector 4 Low liquid level detector 5 Condensate pump 6 Low pressure sensor 7 Electronic expansion valve 8 Wet film humidifier optional FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 413 ...

Page 426: ...the front When there are more than six cabinets in the cold aisle the indoor fan is configured with an air director When replacing the fan the air director needs to be removed Procedure Step 1 Shut down the smart cooling product over the EMS Method 1 Log in to the ECC800 Pro mobile phone or pad app as user admin a Choose Home b Tap the cabinet that houses the smart cooling product in the micro mod...

Page 427: ...after the smart cooling product shuts down over the EMS Step 3 Optional Remove the screw from the air director in the cabinet using a Phillips screwdriver and pull out the air director as shown in Figure 6 13 Figure 6 13 Removing the air director NOTICE In a scenario with two smart cooling products if the fan needs to be maintained or replaced for the lower smart cooling product both the upper and...

Page 428: ... to be removed when only fan 3 is replaced Step 6 Cut the cable tie securing the fan terminal using scissors or diagonal pliers and pull out the fan terminal Step 7 Remove the four M4 screws from the fan using a Phillips screwdriver and remove the fan guard and fan as shown in Figure 6 15 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co...

Page 429: ...here is no alarm the indoor fan is functional Set Indoor fan manual control to 0 and click Submit Step 12 Choose Controls Control Information set Diagnostic mode to Exit and click Submit Step 13 Clear up the indoor fan total runtime Method 1 Log in to the ECC800 Pro mobile phone or pad app as user admin a Choose Home b Tap the cabinet that houses the smart cooling product in the micro module view ...

Page 430: ...t in the cabinet layout diagram d Choose Real time Data OFF Method 2 Log in to the ECC800 Pro WebUI as user admin Choose Monitoring Cooling NetCol5000 A1 Controls Control Information choose Startup Shutdown control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails Step 2 Disconnect th...

Page 431: ...tion If there is no exception release the low liquid level detector NOTE It is normal if a condensate pump faulty alarm is generated during the pump operation when there is no water in the pan The condensate pump generates this alarm for self protection The alarm needs to be cleared manually Step 8 Clear up the condensate pump total runtime Method 1 Log in to the ECC800 Pro mobile phone or pad app...

Page 432: ... a smart cooling product control unit Figure 6 17 Front panel of the smart cooling product control unit 1 Ground point 2 Rectifier 3 PSU 4 FE_2 port for connecting a smart ETH gateway PoE or LAN ports on the ECC 5 FE_1 port for connecting a smart ETH gateway PoE or LAN ports on the ECC 6 CAN_IN input port of the teamwork CAN and northbound RS485 port 7 RS485 12 V port for connecting the T H sensor...

Page 433: ... and pull out the PSU from the subrack as shown by 2 in Figure 6 18 Step 5 Insert the spare PSU into the corresponding slot and flip the clip up to lock the PSU Step 6 Start the smart cooling product over the EMS Method 1 Log in to the ECC800 Pro mobile phone or pad app as user admin a Choose Home b Tap the cabinet that houses the smart cooling product in the micro module view c Tap the smart cool...

Page 434: ...ontrol OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails Step 2 Disconnect the power supply from the smart cooling product control unit after the smart cooling product shuts down over the EMS Step 3 Remove the air director and fan baffle plate by referring to Figure 6 13 and Figure 6 ...

Page 435: ...uses the smart cooling product in the micro module view c Tap the smart cooling product to be set in the cabinet layout diagram d Choose Real time Data OFF Method 2 Log in to the ECC800 Pro WebUI as admin Choose Monitoring Cooling NetCol5000 A1 Controls Control Information choose Startup Shutdown control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the ...

Page 436: ...etCol5000 A1 Controls Control Information set Startup Shutdown control to ON and click Submit Step 11 Choose Controls Control Information set Diagnostic mode to Enter and click Submit Step 12 Choose Running Parameters Diagnostic Mode Parameters set Comp manual control to 3000 rpm and click Submit Choose Running Info Compressor Information and read Suction pressure Check that the suction pressure o...

Page 437: ...ol unit after the smart cooling product shuts down over the EMS Step 3 Remove the cover from the electric control box using a Phillips screwdriver open the compartment that houses the fuse as shown in Figure 6 19 and remove the fuse Figure 6 19 Removing a fuse Step 4 Install a new fuse in the original position by performing the preceding steps in reverse order Step 5 After powering on the smart co...

Page 438: ...ng product in the micro module view c Tap the smart cooling product to be set in the cabinet layout diagram d Choose Real time Data OFF Method 2 Log in to the ECC800 Pro WebUI as user admin Choose Monitoring Cooling NetCol5000 A1 Controls Control Information choose Startup Shutdown control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling p...

Page 439: ...after a period of time the electric heater runs properly Set Elec heater manual control to Closed and click Submit No hot air blows out after a period of time Step 8 Choose Controls Control Information set Diagnostic mode to Exit and click Submit End 6 4 3 1 8 Replacing an EEV and Coil Prerequisites Tools flat head screwdriver welding tool refrigerant retrieval device required based on local condi...

Page 440: ... control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails Step 2 Disconnect the power supply from the smart cooling product control unit after the smart cooling product shuts down over the EMS Step 3 Reclaim the refrigerant Step 4 Pry the EEV coil off using a flat head screwdriver as...

Page 441: ...r range Choose Running Info Electronic Expansion Valve Information Check that the EEV suction overheating degree is within the proper range NOTE The proper range of the suction pressure is 0 7 1 6 MPa and the pressure ratio discharge pressure to suction pressure is greater than 1 4 Table 6 9 lists the proper ranges of the air exhaust pressure The proper range of the air suction superheat degree is...

Page 442: ...N Do not maintain or replace outdoor units during thunderstorms Otherwise your personal safety will be in danger NOTICE You are not advised to maintain or replace outdoor units in rainy days If unavoidable take protective measures to prevent water from entering the outdoor unit When opening the electric control box cover clear water from the cover The following figures show the components of the N...

Page 443: ...or fan blade 2 Safety valve 3 High pressure switch 4 Low pressure switch 5 High pressure sensor 6 Compressor 7 Oil heating belt FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 431 ...

Page 444: ...ature sensor 5 High pressure switch 6 Low pressure switch 7 High pressure sensor 8 Filter dryer 9 Safety valve 10 Discharge temperature sensor 11 Compressor 12 Oil heating belt FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 432 ...

Page 445: ...6 High pressure sensor 7 High pressure switch Figure 6 25 NetCol500 A020 components top view 1 Inductor 2 Module board 3 Ambient temperature sensor 4 Condensate temperature sensor 5 Control board 6 Capacitor FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 433 ...

Page 446: ... Inductor 2 High pressure container 3 Control board 4 Capacitor 5 Module board 6 4 3 2 1 Replacing an Outdoor Fan Prerequisites An outdoor fan needs to be replaced A spare outdoor fan of the same model is available and functional Context Tools Phillips screwdriver small wrench cable tie diagonal pliers Preparation Power off the outdoor unit FusionModule800 Smart Small Data Center User Manual 6 O M...

Page 447: ...s Control Information choose Startup Shutdown control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails Step 2 Disconnect the power supplies from the smart cooling product control unit and the outdoor unit after the smart cooling product shuts down over the EMS Step 3 Remove the top c...

Page 448: ...Figure 6 28 Removing panels for NetCol500 A018 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 436 ...

Page 449: ...Figure 6 29 Removing panels for NetCol500 A020 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 437 ...

Page 450: ...ke out the outdoor fan cable from the electric control box Step 5 Remove the screw from the fan using a small wrench and remove the outdoor fan blades as shown in Figure 6 31 Figure 6 32 or Figure 6 33 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 438 ...

Page 451: ...Figure 6 31 Removing the outdoor fan blades for NetCol500 A018 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 439 ...

Page 452: ...Figure 6 32 Removing the outdoor fan blades for NetCol500 A020 FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 440 ...

Page 453: ...p 9 Install the top cover front panel and left front panel Step 10 After powering on the smart cooling product log in to the ECC800 Pro WebUI as user admin choose Monitoring Cooling NetCol5000 A1 Controls Control Information set Startup Shutdown control to ON and click Submit Step 11 Choose Controls Control Information set Diagnostic mode to Enter and click Submit Step 12 Choose Running Parameters...

Page 454: ...ket wrenches welding tool refrigerant retrieval device required based on local conditions nitrogen injection and pressure preservation tool vacuumization tool refrigerant injection tool protective gloves A compressor needs to be replaced A spare compressor of the same model is available and functional Context Before replacing the compressor disconnect the power supply and discharge refrigerant fro...

Page 455: ...ow Step 4 Remove the left front panel and right rear panel of the outdoor unit and remove the thermal insulation cover to expose the compressor completely Step 5 Remove the nut from the connection box on top of the compressor using an 8 mm socket wrench and disconnect the cable Step 6 Remove the inductor cable and oil heating belt from the compressor Step 7 Weld from the suction and discharge pipe...

Page 456: ...or 5 Welding point for the discharge pipe Figure 6 35 Position of the compressor for NetCol500 A020 1 Welding point for the suction pipe 2 Welding point for the discharge pipe 3 Oil separator 4 Compressor 5 Bolts on the compressor base FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 444 ...

Page 457: ...ll the oil heating belt secure it using cable ties and put a thermal insulation cover on the compressor Step 12 Perform a leakage test with nitrogen again After checking that the smart cooling product does not leak vacuumize the smart cooling product and charge refrigerant Step 13 Reinstall the left front panel and right rear panel Step 14 After powering on the smart cooling product log in to the ...

Page 458: ...tep 17 Set Comp manual control to 0 rpm and click Submit Step 18 Choose Controls Control Information set Diagnostic mode to Exit and click Submit Step 19 Clear up the compressor total runtime Method 1 Log in to the ECC800 Pro mobile phone or pad app as user admin a Choose Home b Tap the cabinet that houses the smart cooling product in the micro module view c Tap the smart cooling product to be set...

Page 459: ...product connection sequence The displayed value prevails Step 2 Disconnect the power supplies from the smart cooling product control unit and the outdoor unit after the smart cooling product shuts down over the EMS Step 3 Reclaim all the refrigerant from the system using a refrigerant retrieval device to ensure that there is no pressure inside the system NOTE Discharge the refrigerant if the local...

Page 460: ...ol500 A018 1 Filter dryer 2 Welding point Figure 6 38 Position of the filter dryer for NetCol500 A020 1 Filter dryer 2 Welding point FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 448 ...

Page 461: ...ep 12 Choose Running Parameters Diagnostic Mode Parameters set Comp manual control to 3000 rpm and click Submit Choose Running Info Compressor Information and read the air suction pressure and air exhaust pressure Check that the air suction exhaust pressure of the compressor is within the proper range Choose Running Info Electronic Expansion Valve Information Check that the EEV suction overheating...

Page 462: ... to be set in the cabinet layout diagram d Choose Real time Data OFF Method 2 Log in to the ECC800 Pro WebUI as admin Choose Monitoring Cooling NetCol5000 A1 Controls Control Information choose Startup Shutdown control OFF and then click Submit NOTE 1 in NetCol5000 A1 is variable and subject to changes with the smart cooling product connection sequence The displayed value prevails Step 2 Disconnec...

Page 463: ...ck that the air suction exhaust pressure of the compressor is within the proper range Choose Running Info Electronic Expansion Valve Information Check that the EEV suction overheating degree is within the proper range NOTE The proper range of the air suction pressure is 0 7 1 6 MPa and the pressure ratio air exhaust pressure to air suction pressure is greater than 1 4 For details about the proper ...

Page 464: ...product connection sequence The displayed value prevails Step 2 Disconnect the power supplies from the smart cooling product control unit and the outdoor unit after the smart cooling product shuts down over the EMS Step 3 Reclaim all the refrigerant from the system using a refrigerant retrieval device to ensure that there is no pressure inside the system NOTE Discharge the refrigerant if the local...

Page 465: ...tion pressure is 0 7 1 6 MPa and the pressure ratio air exhaust pressure to air suction pressure is greater than 1 4 For details about the proper ranges of the air exhaust pressure see 6 4 3 1 8 Replacing an EEV and Coil The proper range of the air suction superheat degree is 4 C to 15 C Step 14 Set Comp manual control to 0 rpm and click Submit Step 15 Choose Controls Control Information set Diagn...

Page 466: ...the EMS Step 3 Reclaim all the refrigerant from the system using a refrigerant retrieval device to ensure that there is no pressure inside the system NOTE Discharge the refrigerant if the local laws and regulations allow Step 4 Remove the top cover front panel and left front panel Step 5 Remove the safety valve using a torque wrench Figure 6 40 Removing the safety valve Step 6 Apply 557 glue to th...

Page 467: ...ls about the proper ranges of the air exhaust pressure see 6 4 3 1 8 Replacing an EEV and Coil The proper range of the air suction superheat degree is 4 C to 15 C Step 13 Set Comp manual control to 0 rpm and click Submit Step 14 Choose Controls Control Information set Diagnostic mode to Exit and click Submit End 6 4 3 2 7 Replacing a Switch for the Outdoor Unit Prerequisites This section applies o...

Page 468: ... head screwdriver Step 5 Use a Phillips screwdriver to remove the card slot that secures the switch Step 6 Remove the switch Step 7 Install a new switch in the original position by performing the preceding steps in reverse order and install a handle Step 8 Power on the smart cooling product turn on the outdoor unit switch Remove the top cover and left front panel as shown in Figure 6 29 If the run...

Page 469: ...main control module is damaged login may fail and backup cannot be performed Step 2 Label each cable and antenna based on the corresponding ports on the ECC800 Pro main control module Step 3 Remove the cables and antenna from the ECC800 Pro main control module Step 4 Loosen the captive screws on both sides of the ECC800 Pro main control module and pull the handles on both sides of the module to re...

Page 470: ... 6 4 4 2 Replacing an ECC800 Pro PSU Prerequisites DANGER Do not touch the terminals in the rear of a removed PSU to avoid electric shocks Tool insulation gloves Materials a reserved undamaged and undeformed PSU of the appropriate model Context The PSU is hot swappable Procedure Step 1 Push the locking latch in the upper right corner of the PSU panel leftwards Step 2 Pull out the handle of the PSU...

Page 471: ...del is available and functional Procedure Step 1 Remove the 4G antenna Step 2 Install the spare 4G antenna cable in the original position and connect it to the ECC800 Pro Figure 6 45 Replacing an antenna End 6 4 4 4 Replacing a SIM Card and MicroSD Card FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 459 ...

Page 472: ...des of the panel of the ECC800 Pro main control module Step 3 Pull the handles on both sides of the panel of the ECC800 Pro main control module and remove the main control module Figure 6 46 Removing the ECC800 Pro main control module Step 4 Remove the SIM card from the card slot Figure 6 47 Removing a SIM card Step 5 Insert the new SIM card into the card slot Figure 6 48 Installing a SIM card Fus...

Page 473: ...ailable and functional Context A smart ETH gateway can be installed in the following two positions based on the project conditions If M shaped cable troughs are deployed for the module install the smart ETH gateway on the M shaped cable trough on the top of the Converged Cabinet NOTICE If two smart ETH gateways are configured install them in positions shown in Figure 6 49 If three smart ETH gatewa...

Page 474: ...t deployed for the module install the smart ETH gateway on the top of the Converged Cabinet as shown in Figure 6 50 Figure 6 50 Position 2 for installing a smart ETH gateway 1 Smart ETH gateway FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 462 ...

Page 475: ...0 Pro Controls and delete the device failing in communication Step 6 Check whether the status indicator of the smart ETH gateway is blinking slowly If yes the smart ETH gateway is functional Step 7 Choose Home Plan View and add a new smart ETH gateway in the appropriate position End 6 4 4 6 Replacing an ETH Converter Prerequisites A spare ETH converter of the same model is available and functional...

Page 476: ...al position and connect the cables End 6 4 4 7 Replacing a Camera Prerequisites Recommended tools and materials inner hexagon screwdriver delivered with the product package step ladder 2 m A camera needs to be replaced A spare camera of the same model is available and functional Procedure Step 1 Remove the front cover of the camera in the direction shown in Figure 6 52 and remove the screws on the...

Page 477: ...ng the camera base from the camera mounting plate as shown in Figure 6 54 Figure 6 54 Removing the camera base Step 4 Disconnect the camera network cable and remove the dome camera Step 5 Install a new camera reconnect the network cable and secure the network camera to the base using screws FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies ...

Page 478: ...1800 disconnect the power supply of the IVS1800 remove the cables from the IVS1800 label the cables and record the original connection positions of the cables NOTICE After removing cables wrap exposed terminals with insulation tape and do not block cable labels If cable labels are blocked cables may be connected incorrectly Step 2 Remove the faulty IVS1800 from the cabinet Step 3 Carry the device ...

Page 479: ...re replacing a faulty disk ensure that the power switch on the rear panel is off and disconnect the power cable to power off the device Context Recommended tools and materials Phillips screwdriver ESD wrist strap or ESD gloves Procedure Step 1 Put on an ESD wrist strap or ESD gloves and insert the ground terminal into the ESD jack in the cabinet Step 2 Remove the faulty hard disk 1 Use a PH2 screw...

Page 480: ...isk port as shown in the lower left figure Figure 6 58 Installing hard disks 2 Insert the hard disk tray back at 45 degrees with the opening of its locking buckle facing downwards hold the screw in the red framed part to lower the hard disk tray until it is level and fasten the black screws on the left and right sides and the white screw on the top Figure 6 59 Fastening the screw on the panel and ...

Page 481: ...rd disk works abnormally contact Huawei technical support 6 4 4 10 Replacing an Aisle T H Sensor 02312PBL Prerequisites Recommended tools Phillips screwdriver flat head screwdriver A T H sensor needs to be replaced A spare T H sensor of the same model is available and functional Procedure Step 1 Open the front door of the cabinet Step 2 Remove the cables from the T H sensor FusionModule800 Smart S...

Page 482: ...or remember the DIP switch setting on it When you install a new T H sensor you need to set the same DIP switch setting for the new one Figure 6 62 Removing a T H sensor Step 4 Install the new T H sensor on its base Step 5 Reconnect the cables to the T H sensor Step 6 Choose Monitoring System ECC800 Controls and delete the device failing in communication FusionModule800 Smart Small Data Center User...

Page 483: ...after it is shut down on the controller home screen Step 2 Remove the cables from the T H sensor NOTICE After removing cables wrap exposed terminals with insulation tape and do not block cable labels If cable labels are blocked cables may be connected incorrectly later Step 3 Remove the faulty T H sensor Step 4 Attach the new T H sensor to an appropriate position on the IT cabinet door frame based...

Page 484: ...able and functional Procedure Step 1 Cut the cable ties on the temperature sensor using diagonal pliers and remove the network cable from the temperature sensor Figure 6 63 Removing a temperature sensor Step 2 Install the spare temperature sensor bind it to the original position using cable ties and connect cables to it FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 ...

Page 485: ...w temperature sensor works properly If its status is displayed on the WebUI of the ECC800 Pro the new temperature sensor works properly 6 4 4 13 Replacing a Smoke Sensor Prerequisites Recommended tools and materials Phillips screwdriver insulation tape step ladder 2 m A smoke detector needs to be replaced A spare smoke detector of the same model is available and functional Context The smoke detect...

Page 486: ...e new smoke detector and reconnect the cables to the new smoke detector Step 4 Install the smoke detector on the base Step 5 Blow smoke towards the smoke detector using a smoke pistol until the smoke detector indicator changes from blinking once every 6s to steady on If a smoke detector fire alarm is triggered the smoke detector is functional End FusionModule800 Smart Small Data Center User Manual...

Page 487: ...verged Cabinet and bound to the rack rail using cable ties The binding position is 5 U away from the cabinet bottom Figure 6 65 Sensor positions 1 Smoke detector A water sensor consists of a water detection rope water detector and conversion cable The water detection rope is laid out on the floor and connected to the water detector placed near the collector by the conversion cable FusionModule800 ...

Page 488: ...nd A connected to the conversion cable 6 Water detection cable Procedure Step 1 Replace the water detector 1 Remove the conversion cable at the conversion port for the water detector and conversion cable 2 Remove the cover from the water detector Figure 6 67 Removing the cover from the water detector FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Tec...

Page 489: ...rring to the preceding steps 5 Connect the new water detector to the conversion cable Figure 6 69 Connecting a conversion cable to a water detector Step 2 Replace a water detection cable 1 Remove the faulty water detection cable from the port 2 Install a new water detection cable FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 477 ...

Page 490: ...End 6 4 4 15 Replacing an Electrode Water Sensor Prerequisites Recommended tools and materials Phillips screwdriver crimping tool A water sensor needs to be replaced A spare water sensor is available Procedure Step 1 Disconnect the cable between the water sensor and the ECC800 Pro Step 2 Remove the faulty water sensor Step 3 Place the new water sensor in the correct position Step 4 Connect the wat...

Page 491: ...ht Actuator Impact on the System The eLight strip light is off during replacement Prerequisites Tools ESD gloves Phillips screwdriver step ladder label marker Material eLight actuator Figure 6 71 Positions of the eLight actuator and power module 1 eLight actuator 2 eLight power module Procedure Step 1 Label each cable based on the corresponding ports on the eLight actuator Step 2 Remove cables fro...

Page 492: ...1 eLight actuator 2 eLight power module Procedure Step 1 Disconnect the upstream fuse for the eLight power supply Step 2 Label each cable based on the corresponding ports on the eLight actuator Step 3 Remove cables from the eLight actuator Step 4 Remove the old eLight actuator from guide rails Step 5 Install the spare eLight actuator in the original position and connect the cables Step 6 Connect t...

Page 493: ...nected to the power over Ethernet PoE port on the access actuator Step 3 Remove other cables connected to the access actuator and label the cables Step 4 Replace the faulty access actuator with a new one Step 5 Connect cables to the new access actuator Step 6 Reinstall the cover for the waterproof box of the access actuator FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02...

Page 494: ...print and Card Reader with a Keypad Prerequisites Recommended tool Phillips screwdriver A fingerprint and card reader with a keypad needs to be replaced A spare fingerprint and card reader with a keypad of the same model is available and functional Context Figure 6 75 Fingerprint and card reader with a keypad Procedure Step 1 Remove the screws that secure the fingerprint and card reader with a key...

Page 495: ... delivered with it Step 7 Choose Monitoring System ECC800 Pro Controls and delete the device failing in communication Step 8 Refer to the section about commissioning the in room access control system in the installation guide and check that the fingerprint and card reader with a keypad functions properly End 6 4 4 21 Replacing a Fingerprint and Card Reader Prerequisites Recommended tool Phillips s...

Page 496: ...1 2 and 3 in Figure 6 78 Figure 6 78 Removing the bottom plate Step 2 Remove the original bottom plate as shown by 4 in Figure 6 78 Step 3 Take out the bottom plate of the new fingerprint and card reader and secure it Step 4 Connect the cable FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 484 ...

Page 497: ...t the fingerprint and card reader with a keypad functions properly End Follow up Procedure Configure the new fingerprint and card reader by following the instructions provided in the document delivered with the ECC800 Pro 6 4 4 22 Replacing a Card Reader with a Keypad Prerequisites Recommended tool Phillips screwdriver A card reader with a keypad needs to be replaced A spare card reader with a key...

Page 498: ...tem ECC800 Controls and delete the device failing in communication Step 8 Refer to the section about commissioning the in room access control system in the installation guide and check that the fingerprint and card reader with a keypad functions properly End Follow up Procedure Configure the new card reader with a keypad by following the instructions provided in the document delivered with the ECC...

Page 499: ... 82 3 Remove the screws that secure the base as shown by 4 in Figure 6 82 4 Disconnect cables and remove the emergency door release button Figure 6 82 Removing an emergency door release button Step 2 Install a new emergency door release button 1 Connect cables 2 Tighten screws on the base as shown by 1 in Figure 6 83 3 Install the glass panel as shown by 2 and 3 in Figure 6 83 FusionModule800 Smar...

Page 500: ...elease button Step 4 Remove the cover of the emergency door release button using a Phillips screwdriver and remove the glass If the room door can be opened normally the emergency door release button is functional Step 5 Install the emergency door release button End FusionModule800 Smart Small Data Center User Manual 6 O M Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 488 ...

Page 501: ... 5 Power system 380V 400V 415V 3Ph N 50Hz 60Hz Voltage range 342 456 V Voltage frequency range 50 60 Hz 3 Hz Total IT equipment power 8 5kW Maximum power of a single cabinet 7 kW high temperature condition 6 kW IP rating IP20 Altitude 0 4000 m derated when the altitude exceeds 1000 m Installation mode Installed on a concrete floor a raised floor or an ESD floor FusionModule800 Smart Small Data Cen...

Page 502: ... be routed out from the top or bottom Operating temperature Indoor 0 C to 40 C outdoor 20 C to 45 C normal temperature version 40 C to 45 C low temperature version outdoor 10 C to 55 C high temperature version Storage temperature Without refrigerant 40 C to 70 C With refrigerant 40 C to 55 C Storage humidity 95 RH non condensing FusionModule800 Smart Small Data Center User Manual 7 Technical Speci...

Page 503: ...capacity equal to that of the compressor shortens the compressor runtime and saves energy The fluorine pump mode also provides 12 5 kW cooling capacity when the outdoor temperature lower than 5 C outdoor is low The total power of the equipment is 2 6 kW when the compressor is running and it is about 1 2 kW when the fluorine pump is running The cooling capacity in 1 2 kW fluorine pump mode is basic...

Page 504: ... Suction sensor 19 Indoor unit gas pipe stop valve 20 Outdoor unit gas pipe stop valve 21 Low pressure sensor 22 Gas liquid separator 23 Pre compressor solenoid valve 24 Compressor bypass check valve 25 Low pressure switch Figure A 2 Refrigerant flow diagram compressor mode Figure A 3 Refrigerant flow diagram fluorine pump mode FusionModule800 Smart Small Data Center User Manual A Fluorine Pump Pr...

Page 505: ...a level 15ºC Table B 1 Derating coefficients of the UPS2000 G Altitude Unit m Derating Coefficients 1000 1 0 1500 0 95 2000 0 91 2500 0 86 3000 0 82 3500 0 78 4000 0 74 4500 0 7 5000 0 67 FusionModule800 Smart Small Data Center User Manual B Equipment Derating Coefficients Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 493 ...

Page 506: ...ommunication interface module CPLD complex programmable logical device D DC direct current DSP digital signal processing E ECO economy control operation EOD end of discharge EPO emergency power off ESM energy storage module ESMU energy storage management unit ESN equipment serial number FusionModule800 Smart Small Data Center User Manual C Acronyms and Abbreviations Issue 01 2021 02 05 Copyright H...

Page 507: ...2 Recommended Standard 232 RS485 Recommended Standard 485 S SELV safety extra low voltage SOC state of charge SOH state of health SPD surge protective device SSH Secure Shell T THDv total harmonic distortion of output voltage TNV telecommunication network voltage U UPS uninterruptible power system USB Universal Serial Bus FusionModule800 Smart Small Data Center User Manual C Acronyms and Abbreviat...

Page 508: ...V VRLA valve regulated lead acid FusionModule800 Smart Small Data Center User Manual C Acronyms and Abbreviations Issue 01 2021 02 05 Copyright Huawei Technologies Co Ltd 496 ...

Reviews: