Check Item
Requirement
Compliance
Surge protection
Complies with requirements
in
.
□
Y
□
N
□
N/A
Power supply facility
Complies with requirements
in
.
□
Y
□
N
□
N/A
Electromagnetic shielding
Complies with requirements
in
□
Y
□
N
□
N/A
3.1.3 Instruments Required for the Installation
This section describes the instruments and meters for installing the USG.
lists the required instruments and meters for USG installation.
Table 3-2
Required instruments and meters
Category
Instrument/Meter
Measuring and
lineation instruments
l
Ruler: used to measure length.
l
Marker: used to indicate specific lengths with drawn lines.
Fastening tools
l
Flat-head screwdriver: used to fasten small screws and bolts.
l
Phillips screwdriver: used to fasten small screws and bolts.
Drilling tools
l
Hammer drill: used to drill mounting holes during wall-
mounting.
l
Vacuum cleaner: used to remove dust and debris produced
while drilling holes.
l
Hammer: used to drive the hollow wall anchors into mounting
holes.
Pliers
l
Needle-nose pliers: used to hold small fittings and twist fine
wires in a narrow workplace.
l
Diagonal cutting pliers: used to cut insulated sleeves and tie
wraps.
Auxiliary tools
l
Knife: used to peel the insulated sleeve from the cable.
l
Ladder: used to access overhead cabling.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
244