background image

About This Document

Purpose

This document describes the battery boxes designed for the UPS2000-A-(1 kVA–3

kVA) series in terms of appearance, technical specifications, installation, and

connections.

Intended Audience

This document is intended for:

Technical support engineers

Hardware installation engineers

Commissioning engineers

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Remarks

Indicates a hazard with a high level of risk

which, if not avoided, will result in death or

serious injury.

Indicates a hazard with a medium level of

risk which, if not avoided, could result in

death or serious injury.

Indicates a hazard with a low level of risk

which, if not avoided, could result in minor

or moderate injury.

Indicates a potentially hazardous situation

which, if not avoided, could result in

equipment damage, data loss, performance

deterioration, or unanticipated results.
NOTICE is used to address practices not

related to personal injury.

UPS2000-A-(1 kVA–3 kVA) Battery Box

Quick Guide

About This Document

Issue 05 (2022-05-23) Copyright © Huawei Digital Power Technologies Co., Ltd.

ii

Summary of Contents for UPS2000-A-1 kVA

Page 1: ...UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide Issue 05 Date 2022 05 23 HUAWEI DIGITAL POWER TECHNOLOGIES CO LTD ...

Page 2: ... features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been mad...

Page 3: ...igh level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss ...

Page 4: ...36V12 9 2AHBPVBB C ESS 72V12 9 2AHBPVBB C and ESS 96V12 9 2AHBPVBB01 C which are applicable only in China 04 2016 05 15 Updated the documentation 03 2015 10 20 Updated the diagrams of connections between battery boxes and a UPS 02 2015 08 29 Updated the document specifications 01 2015 06 25 This is the first official release UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide About This Document Issue 0...

Page 5: ...on Procedure 7 3 1 Unpacking and Checking 8 3 2 Installation Preparations 8 3 3 Procedure 9 4 Connecting Battery Boxes to a UPS 10 4 1 Connecting Battery Boxes to a 1 kVA UPS 10 4 2 Connecting Battery Boxes to a 2 kVA UPS 10 4 3 Connecting Battery Boxes to a 3 kVA UPS 11 A Acronyms and Abbreviations 12 UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide Contents Issue 05 2022 05 23 Copyright Huawei Digi...

Page 6: ...n the case of fire use a dry powder extinguisher Liquid extinguishant may cause electric shocks Do not touch uninsulated battery terminals Otherwise electric shocks may occur Using incorrect battery models may cause explosion Dispose of used batteries by following instructions Cut off power supply and remove metal objects such as watches and rings before maintenance Do not transport the equipment ...

Page 7: ...e 3 kVA UPS with long backup time is ESS 96V12 9 2AHBPVBB01 or ESS 96V12 9 2AHBPVBB01 C applicable only in China The three models of battery boxes have similar appearances This document uses the standard battery box ESS 96V12 9 2AHBPVBB01 for the 3 kVA UPS with long backup time as an example as shown in Figure 2 1 Figure 2 1 Appearance and external ports of the standard battery box ESS 96V12 9 2AH...

Page 8: ...BPVBB C applicable only in China two strings of 9 Ah 36 V DC built in batteries Interior Contains two battery strings Each string contains three 9 Ah 12 V DC batteries The output voltage of the battery box is 36 V DC Basic Features Appearance black Panel material plastic Rear panel color gray SECC SGCC Dimensions H x W x D 220 mm x 145 mm x 397 mm Weight 20 kg UPS2000 A 1 kVA 3 kVA Battery Box Qui...

Page 9: ... in China two strings of 9 Ah 72 V DC built in batteries Interior Contains two battery strings Each string contains six 9 Ah 12 V DC batteries The output voltage of the battery box is 72 V DC Basic Features Appearance black Panel material plastic Rear panel color gray SECC SGCC Dimensions H x W x D 318 mm x 190 mm x 421 mm Weight 40 4 kg UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide 2 Appearance a...

Page 10: ...12 9 2AHBPVBB01 or ESS 96V12 9 2AHBPVBB01 C applicable only in China two strings of 9 Ah 96 V DC built in batteries Interior Contains two battery strings Each string contains eight 9 Ah 12 V DC batteries The output voltage of the battery box is 96 V DC Basic Features Appearance black UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide 2 Appearance and Characteristics Issue 05 2022 05 23 Copyright Huawei...

Page 11: ...nterior Figure 2 6 ESS 96V12 9 2AHBPVBB01 or ESS 96V12 9 2AHBPVBB01 C battery box interior left Figure 2 7 ESS 96V12 9 2AHBPVBB01 or ESS 96V12 9 2AHBPVBB01 C battery box interior right UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide 2 Appearance and Characteristics Issue 05 2022 05 23 Copyright Huawei Digital Power Technologies Co Ltd 6 ...

Page 12: ...boxes of different models together For details see the nameplate on the enclosure The following figures are for reference only Figure 3 1 Same model Figure 3 2 Different models UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide 3 Installation Procedure Issue 05 2022 05 23 Copyright Huawei Digital Power Technologies Co Ltd 7 ...

Page 13: ...he equipment by holding the front panel or wiring port covers Do not wear rings watches or other metal objects when moving the battery box 3 2 Installation Preparations NOTICE Get tools insulated to prevent electric shocks Table 3 1 Installation tools Name Specifications and Appearance Multimeter Phillips screwdriver PH2 x 150 mm PH3 x 250 mm Flat head screwdriver 2 mm x 80 mm Torque screwdriver W...

Page 14: ...draulic pliers Cable tie 3 3 Procedure A tower mounted battery box does not need any additional installation procedure but can be placed on a stable installation surface UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide 3 Installation Procedure Issue 05 2022 05 23 Copyright Huawei Digital Power Technologies Co Ltd 9 ...

Page 15: ...er Before connecting cables ensure that the battery box circuit breaker is OFF Figure 4 1 Connection between the ESS 36V12 9 2AHBPVBB or ESS 36V12 9 2AHBPVBB C battery boxes and a UPS 4 2 Connecting Battery Boxes to a 2 kVA UPS A maximum of two ESS 72V12 9 2AHBPVBB or ESS 72V12 9 2AHBPVBB C applicable only in China battery boxes can be connected in parallel A battery box has two output ports that ...

Page 16: ...as two output ports that are connected in parallel and have the same functions If one of the output ports is used to connect to a UPS or battery boxes connected in parallel the other can be used to connect to an external charger Other spare ports on the battery box can also be used to connect to the external charger Before connecting cables ensure that the battery box circuit breaker is OFF Figure...

Page 17: ...nyms and Abbreviations U UPS uninterruptible power system UPS2000 A 1 kVA 3 kVA Battery Box Quick Guide A Acronyms and Abbreviations Issue 05 2022 05 23 Copyright Huawei Digital Power Technologies Co Ltd 12 ...

Reviews: