Table 6-1
Basic configuration for the emergency WS
Item
Configuration
CPU
2 × Intel Xeon DP 2.4 GHz or higher
Hard disk
2 × 36 GB 10000RPM SCSI hard disks or more
Memory
1 GB or more
Network adapter
2 × 1000M integrated network adapters
2 × 1000M extended network adapters
RAID card
Built-in RAID. RAID 0 and RAID 1 are supported.
Video adapter
Integrated ATI Rage XL video controller with 8 MB
buffer
6.5 Communication Gateway Software
Except Ethernet, the communication gateway provides another communication way
between the BAM and workstations, namely, serial communication. To achieve such
communication, you can interconnect the BAM and respective workstations through
serial cables. Communication gateways include MRS6100 Server Gateway Tool and
MRS6100 WorkStation Gateway Tool. They fulfill the protocol conversion between
the TCP/IP network interface and the RS232 serial port.
The communication gateway software of the BAM and workstations includes the
communication gateway software at the BAM and that at the WS. The BAM can be
accessed to the alarm box after the MRS6100 Server Gateway Tool is configured,
including setting serial port numbers and setting the client application type (New
AlarmBox Class).It is suggested that the alarm box be accessed to the emergency
workstation, as shown in Figure 6-6.