TP48200A-D14A1 Telecom Power
User Manual
5 System Maintenance
Issue 04 (2019-12-20)
Copyright © Huawei Technologies Co., Ltd.
27
5
System Maintenance
5.1 Routine Maintenance
The TP48200A-D14A1 is maintained every six months. If faults are identified, clear them
immediately.
Table 5-1
Maintenance
Item
Check Whether
Check Method
Repair When
Measures
Electricity
The voltage output
is normal.
Using a multimeter
The BLVD or
LLVD voltage
exceeds the
threshold.
For details, see
section 5.2
Troubleshooting
Preventive
maintenance
inspection (PMI)
Indicators are
normal.
Observing
indicators
Alarms are
generated.
Cabinet appearance
The paint or the
electroplated
coating on the
cabinet are flaking
off or scratches
occur.
Observing the
cabinet
The cabinet surface
is damaged or
distorted.
Repaint and repair
the cabinet.
5.2 Troubleshooting
5.2.1 Troubleshooting Common Faults
Table 5-2
Common faults and troubleshooting methods
Fault Type
Fault Analysis
Handling Method
AC power off
AC input cable fault
1.
Check whether the DC input cable is correctly and