Parameter Name
Description
Communication
disconnection fail-safe
In the SUN2000 anti-backfeeding
scenario, if this parameter is set to
Enable, the SUN2000 will derate
according to the active power
derating percentage when the
communication between the
SUN2000 and the Smart Dongle is
disconnected for a period longer than
Communication disconnection
detection time.
Communication
disconnection
detection time
Specifies the time for determining the
communication disconnection
between the SUN2000 and the
Dongle.
This parameter is displayed when
Communication disconnection fail-
safe is set to Enable.
----End
7.2.1.2 Battery Control
Function
If the SUN2000 connects to a battery, you need to set battery parameters.
Forcible Charge and Discharge
Step 1 On the home screen, choose Power adjustment > Battery control > Forced
charge/discharge and perform operations as required. Tap Submit.
Figure 7-11 Forced charge/discharge
SUN2000-(2KTL-6KTL)-L1
User Manual
7 Man-Machine Interaction
Issue 04 (2021-04-01)
Copyright © Huawei Technologies Co., Ltd.
71