Prerequisites
l
You must be logged in to the system through a local serial port. For the configuration
process, see
3.1.1 Configuring Management Through a Local Serial Port
.
l
The IP address of the maintenance terminal must be properly configured.
NOTE
In the following operations, the configurations of the MA5616 must be performed through a local serial
port.
Networking - LAN
shows an example network for configuring inband management over a LAN in the
telnet mode.
Figure 3-16
Example network for configuring inband management over a LAN in the telnet
mode
MA5616
PC
PC
PC
LAN
LAN Switch
Data Plan - LAN
provides the data plan for configuring inband management over a LAN in the telnet
mode.
Table 3-3
Data plan for configuring inband management over a LAN in the telnet mode
Item
Data
Upstream port of the
MA5616
l
VLAN ID: 30
l
Port ID: 0/0/0
l
IP address: 10.10.20.2/24
Ethernet port of the
maintenance terminal
IP address: 10.10.20.3/24