The procedure for performing a calling party emulation test is as follows:
1.
The user runs the
pots emulational-caller caller-port
command to start the calling
party emulation test on the voice service port.
2.
The calling party calls the called party that uses the test phone.
3.
After hearing ringing tones, the called party picks up the phone.
4.
After hearing announcements, the called party presses
*
to confirm the off-hook.
5.
The device exports the emulation test result. The calling party emulation test is
complete.
l
The procedure for performing a call emulation test is as follows:
1.
The user runs the
pots emulational-call
command to start the call emulation test on the
voice service port.
2.
The device automatically performs the test and exports the emulation test result.
----End
Result
After completing the call emulation test, the device directly outputs the test result. The test result
is used to check whether the call is normal.
Reference
In a calling or called part emulation test, the voice service port on the MA5612 can be used for
the calling or called party manually. A call emulation test is a test in which two ports on the
MA5612 work as the calling and called parties respectively. In this case, the system emulates
on-hook and off-hook by the calling and called parties without manual operations and stops the
test after the call lasts several minutes.
The test phone is placed in the test station. The call emulation test can be performed between
this phone set and the user configured on the MA5612. In this manner, you can remotely check
whether the voice service on the MA5612 is normal.
The call emulation test can be used only to check whether the communication on the network
side of the device is normal.
8.9 PPPoE Dialup Emulation Test
In the PPPoE dialup emulation test, the test device is emulated as the PPPoE client to perform
the dialup test on the BRAS. Thus, the test is used to check whether the PPPoE dialup is
successful through the check on the connectivity between the MA5612 and the BRAS. When
the PPPoE dialup fails, the result of the PPPoE dialup emulation test is used to locate faults.
Context
l
The configuration of the PPPoE user is correct.
l
If the VLAN that the service stream belongs to is QinQ VLAN, the MA5612 does not
support the PPPoE dialup emulation.
l
Currently, the MA5612 supports the dialup emulation of one user at a time.