excessively long distance between the equipment and the position where the cable is
secured.
Coil the excess of the fiber optic cables near the equipment on the tower before securing
the cables on the tower.
8.2 RRU Cable Connections
This section describes RRU cable connections.
The RRU does not support power cable cascading.
Figure 8-9 and Figure 8-10 show the cable connections of a single-mode RRU.
When the following scenarios need to be monitored by RRUs,
If the external power supply system needs to be monitored and supports modulating RS485 and dry
contact alarm signals using power cables, you do not need to install the MEB.
In other scenarios, you need to install MEB. For details about MEB and MEB cable installation, see
MEB06D User Guide
.
Figure 8-9
Cable connections of a single-mode RRU (MEB not installed)
(1) RRU PGND cable
(2) RRU RF jumper
(3) RRU AISG multi-wire cable
(4) RRU AISG extension cable
(5) RRU power cable
(6) CPRI optical fiber