Appendix
Making OT Terminals by Using a Cable Peeler (Recommended)
b
Add two OT terminals to the end of the power cable connecting to the RRU.
The assembling of OT terminals to the power cable must be complete before the RRU is installed on a
metal pole.
Determine lengths of power cables for different
operations according to the scales on the inner
side of the cover plate of the cabling cavity.
Based on the determined length, remove the
jacket and shielding layer off the power cable.
Add an OT terminal to each wire.
Strip a 15 mm jacket off the power cable to
reveal the shielding layer of the power cable
Remove the jacket from each wire.
Label for preparing
the power cable
-48V DC power cable
Shielding layer
OT terminals
NEG ( - )
RTN ( + )