a.
Open the plastic clip and place the power cable in the plastic clip. See step (1) in
Figure3 Connecting a power cable (secured with the PSU using a plastic clip)
.
Then close the plastic clip. See step (2) in
Figure3 Connecting a power cable
(secured with the PSU using a plastic clip)
.
Figure 7-17
Connecting a power cable (secured with the PSU using a plastic clip)
b.
Open the lock of the plastic clip. See a of step (3) in
cable (secured with the PSU using a plastic clip)
. Slide the plastic clip towards
the PSU socket to ensure that the plastic clip is close to the connector of the power
cable. See b of step (3) in
Figure3 Connecting a power cable (secured with the
.
----End
7.10.2 Installing a DC PSU
Install a DC PSU to replace the original one.
A DC PSU needs to be added to improve reliability when the RH2288 V3 is configured with
only one DC PSU.
Procedure
Step 1
Wear an ESD wrist strap. For details, see
Step 2
Remove the PSU to be replaced. For details, see
Step 3
Take the spare DC PSU out of its ESD bag.
Step 4
Push the spare DC PSU along the guide rails into a slot (for example, slot 1) until you hear a
sound.
The PSU latch snaps in so that the PSU does not move. See
RH2288 V3 Server
User Guide
7 Replacing Parts
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
144