Parameter
Description
Status
This parameter indicates the running status of a fan. The status can be
Normal
or
Fault
.
----End
Exception Handling
l
If the running status of the fan is
Fault
” in the
OceanStor S5000 Series
Storage System Alarm Reference
.
l
If an alarm that is related to the fan is displayed on the alarm interface, handle it by referring
to the suggestion in the alarm items.
If the fault persists, contact the technical support engineers.
5.4 Checking the Status of the Power Supply
This section describes how to check the power supply on the controller subrack through the
OSM.
Reference Standard
l
No new alarms related to the power supply are displayed on the alarm interface.
l
The running status of the power supply is
Normal
.
Procedure
Step 1
Log in to the OSM.
Step 2
On the main menu, click
Device
.
Step 3
In the navigation, click
Controller Subrack xx
(
xx
indicates the controller subrack ID).
NOTE
The parameters of the power supply in the disk subrack is the same as controller subrack. To check the
status of the power supply in the disk subrack, click
Device
on the main menu, and then click
Disk Subrack
xx
(
xx
indicates the disk subrack ID) in the navigation tree.
Step 4
In the navigation tree, click
PEM
.
Step 5
Click the
PEM0
or
PEM1
tab to view the information about the PEM. The parameter description
Table 5-4
Parameter description of power supply status interface
Parameter
Description
Subrack ID
This parameter indicates the ID of the disk subrack where the PEM is located.
OceanStor S5000 Series Storage System
Routine Maintenance
5 Routine Maintenance Guide of the OSM
Issue 01 (2010-04-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5-7