Operation Manual – 802.1x
Quidway S3100 Series Ethernet Switches
Chapter 3 System-guard Configuration
Huawei Technologies Proprietary
3-2
Table 3-2
Configure system-guard related parameters
Operation
Command
Description
Enter system view
system-view
—
Configure
system-guard-related
parameters
system-guard mode
rate-limit
interval-time
threshold timeout
Required
The default
system-guard-related
parameters are as follows.
z
interval-time
: 5 seconds
z
threshold
:
64
z
timeout
: 60 seconds
3.2.3 Specifying system-guard-enabled ports
Table 3-3 lists the operations to specify system-guard-enabled ports.
Table 3-3
Specify system-guard-enabled ports
Operation
Command
Description
Enter system view
system-view
—
Specify
system-guard-enabled
ports
system-guard permit
interface-list
Required
3.3 Displaying and Debugging the System-guard Function
After the above configuration, you can display and verify your configuration by
performing the operation listed in Table 3-4.
Table 3-4
Display and debug the system-guard function
Operation
Command
Description
Display
system-guard
configuration
display system-guard
config
This command can be
executed in any view.
3.4 System-guard Configuration Example
I. Network requirements
S3100-2 and S3100-3 have users directly attached. They are connected upstream to
S3100-1.