Field
Value Range
Description
Effective Status
Valid, Invalid
Specifies whether the clock
source is valid. This
parameter is used for query
only.
Lock Status
Lock, Unlock
Default value: Unlock
The
Lock Status
parameter
indicates the lock status of a
clock source in the priority
table.
You can click
information.
Switching Source
For example: 1-SL1D-1
(SDH-1)
Displays the clock source to
be traced by the NE after the
switching.
Switching Status
Forced Switching, Manual
Switching, Normal
Displays the switching status
of the current clock source.
2.8.3 Clock Quality and Status Management
You can manage the quality and status of a clock to ensure the stability and precision of the
clock source that is currently traced.
lists the parameters that are used for managing the quality and status of a clock.
Table 2-6
Parameter description: clock synchronization status
Field
Value Range
Description
NE Name
For example: NE(9-5595)
Displays the name of the NE.
NE Clock Working Mode
Normal Mode, Holdover
Mode, Free-Run Mode
Default value: -
The
NE Clock Working
Mode
parameter is used to
set the current working mode
of the system clock to the
normal, holdover or free-run
mode.
You can click
display the detailed
information.
2 Creating the Network
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
2-30
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)