Field
Value Range
Description
Clock Source Threshold
No Threshold Value, G.813
SETS Signal, G.812 Lock
Clock Signal, G.812 Transit
Clock Signal, G.811 Clock
Signal
Default value: No Threshold
Value
The
Clock Source
Threshold
parameter
indicates the lower quality
threshold of 2M external
clock source. When the clock
quality level of the external
clock source that is selected
from the 2M phase-locked
source priority table is
inferior to the threshold, the
2M phase-locked source
becomes invalid, and the
action specified for 2M
phase-locked source failure
is invoked to control the
external clock source output.
You can click
to display
the detailed information.
lists the parameters that are used for configuring the 2M phase-locked source attributes
of an external clock.
Table 2-4
Parameters for configuring the 2M phase-locked source attributes of an external clock
Field
Value Range
Description
2M Phase-Locked Source
Number
For example: NE
(9-5595)-2M phase-locked
source 1
Displays the number of the
external clock source output
of the NE.
External Clock Output
Switch
Open, Close
Specifies the output switch of
the external clock source.
External Clock Output Mode 2 MHz, 2 Mbit/s
Default value: 2 Mbit/s
The
External Clock Output
Mode
parameter is used to
set the output mode of the
external clock source to 2
Mbit/s or 2 MHz.
You can click
to display the detailed
information.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
2 Creating the Network
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-25