4.5.4 Configuration Process (End-to-End Mode)
4.5.1 Networking Diagram
The completely isolated data services of two users at a station must be transported to another
station.
Service Requirement
In the network as shown in
, the service requirements are as follows:
l
The two branches of user A that are located at NE1 and NE3 need to communicate with
each other over Ethernet. A 10 Mbit/s bandwidth is required.
l
The two branches of user B that are located at NE1 and NE3 need to communicate with
each other over Ethernet. A 20 Mbit/s bandwidth is required.
l
The services of user A must be isolated from the services of user B.
l
The Ethernet equipment of user A and user B provides 100 Mbit/s Ethernet ports of which
the working mode is auto-negotiation, and does not support VLANs.
Figure 4-24
Networking diagram of the EPL services
NM
NE3
NE2
NE1
NE4
User A2
PORT1
PORT2
PORT1
PORT2
VCTRUNK
User A1
User B1
User B2
6-SL4D-
1
6-SL4D-
1
6-SL4D-
2
6-SL4D-
2
4-EFS8
6-SL4D-1
NE3:
NE1:
6-SL4D-1
6-SL4D-2
NE2:
Line board
Ethernet board
4-EFS8
6-SL4D-2
Line board
Ethernet board
Line board
Line board
4 Configuring Ethernet Services