6 Initializing the Storage System 

18 

Install the following host software programs on the application server: 

1. BCManager eReplication. For details about how to install BCManager eReplication, refer to 

the OceanStor BCManager 

eReplication User Guide

2. UltraPath, a multipathing program. For details about how to install UltraPath, refer to the 

OceanStor UltraPath for Windows 

User Guide, OceanStor UltraPath for Linux User Guide, OceanStor UltraPath for Solaris User Guide, OceanStor UltraPath 

for AIX User Guide, 

or 

OceanStor UltraPath for vSphere User Guide

3. eService. For details about how to install eService, refer to the 

OceanStor eService User Guide

4. SystemReporter. For details about how to install SystemReporter, see the corresponding 

OceanStor SystemReporter User 

Guide

 For details about initializing the storage system, refer to the 

OceanStor Dorado3000 V3, Dorado5000 V3, and 

Dorado6000 V3 V300R002 Installation Guide

 The default user name and password of the storage system are 

admin

 and 

Admin@storage

 respectively. 

 You must change the default password immediately after you have logged in to the storage system for the first time 

and periodically change your password in the future. This reduces the password leakage risks. The command to 

change password is 

change user_password

.

 

For details about how to change the password in DeviceManager, see 

the 

OceanStor Dorado V3 Series V300R002 Administrator Guide. 

 If you do not change the IP address of the management network port, use the port's default IP address (see the 

appendix) to log in to OceanStor DeviceManager. Ensure that the maintenance terminal has been connected to the 

management network port of the storage system using a network cable, and the IP address of the maintenance 

terminal is on the same network segment as the default IP address of the management network port. 

7 (Optional) Installing Host Software 

After you have powered on the storage system, perform the following steps to initialize it: 
1. Connect the serial port on the controller enclosure to the maintenance terminal.  
2. Log in to the CLI of the storage system using remote login software (such as PuTTY, and set 

Speed

 to 

115200

). 

3. Run the 

change system management_ip 

command to change the IP address of the management network port. 

4. Log in to OceanStor DeviceManager on the maintenance terminal using the IP address of the management network port. 

a. Run Internet Explorer on the maintenance terminal.  
b. In the address box, type 

https://

XXX.XXX.XXX.XXX

:8088

 and press 

Enter

.  

 
 
 

 
 
 
 
 
 
 
 
c.

Type the user name and password in 

Username

 and 

Password

.  

5. In DeviceManager, follow the 

Settings

 > 

Initial Configuration 

wizard to change the basic information, configure the device 

time, disk domain, and alarm notification, and import license files. If you do not perform the initial configuration as prompted, 
follow-up configuration and use of services will be affected. 

 Obtain the documentation related to the software from the Huawei technical support website. For more 
information about installing host software, refer to the 

OceanStor Dorado3000 V3, Dorado5000 V3, and 

Dorado6000 V3 V300R002 Installation Guide. 

 After installing the storage system, log in to 

https://support.huawei.com/enterprise/

, choose 

TECHNICAL 

SUPPORT 

Product Support 

Enterprise Data Center 

Enterprise Storage

, and click the product 

model to go to the document page of the product. Then, search for, browse, and download the 

Acceptance 

Test Guide

 

of the corresponding version.  

 You can download PuTTY from chiark website. 

 You are advised to use the latest version of PuTTY. Otherwise, you may fail to log in to the storage system. 

In V300R002C00 or in V300R002C10 and later where OceanStor Dorado NAS units are not configured, 

XXX.XXX.XXX.XXX

 indicates the IP address of the management network port on the controller enclosure of 

the storage system. 

In V300R002C10 and later where OceanStor Dorado NAS units are configured, 

XXX.XXX.XXX.XXX

 indicates 

the IP address of the management network port on the OceanStor Dorado NAS unit upon your first login. 

If a firewall is configured, you should enable port 8088 for the system to provide web services externally. 

Your web browser may display a security certificate error. If the IP address is correct, you can neglect the 
prompt and continue to access the storage system. 

Summary of Contents for OceanStor V300R002

Page 1: ...asy management This guide describes how to quickly install OceanStor Dorado3000 V3 and Dorado5000 V3 storage systems For more information see the OceanStor Dorado3000 V3 Dorado5000 V3 and Dorado6000 V3 V300R002 Installation Guide You can obtain the product documentation from https enterprise huawei com You can also register for a Huawei support account at this website to browse and download valuab...

Page 2: ...trap whose ground terminal is a metal clip Safety Information CAUTION Do not remove or insert controllers disks or cables during the power on process to prevent data loss Ensure that a storage system is properly grounded before powering it on to prevent the storage system from being damaged NOTICE 2 Wearing ESD gloves Wearing an ESD wrist strap 1 Stretch your hand through the ESD wrist strap 2 Fas...

Page 3: ...ecting Cables Powering On the Storage System Checking Hardware Installation Optional Installing Host Software Checking installation tools Checking circuit breakers Checking components Planning device installation positions Removing filler panels from device installation positions Determining device installation positions using installation templates Installing guide rails Installing storage device...

Page 4: ...000 V3 SAS support 2 U SAS disk enclosures and Dorado5000 V3 Enhanced Edition SAS supports both 2 U SAS and NVMe disk enclosures The following sections describe the process for installing the Dorado5000 V3 NVMe The process for installing the Dorado3000 V3 and Doardo5000 V3 series SAS is similar 4 Checking installation tools Checking circuit breakers 1b 1a NOTICE Controller enclosure 2 U Applicable...

Page 5: ... V3 Enhanced Edition SAS is equipped with four 2 U disk enclosures the space required by a cabinet can be calculated as follows 10 U 2 U 2 U x 4 Note The height of the storage system is measured by the unit of U 1 U equals 44 45 mm 1 75 inches Tips 5 Install the controller enclosure in the middle of a cabinet between 19 U and 20 U Controller enclosure 2 U Disk enclosure 2 U Disk enclosure 2 U Disk...

Page 6: ...age devices Installation positions of 2 U device fixing screws Installation positions of guide rail fixing screws 6 NOTE Installing guide rails 2d The adjustable guide rails are 600 mm 23 62 inches to 900 mm 35 43 inches long The adjustable guide rails are preconfigured with positioning pins before delivery Two paired adjustable guide rails must be positioned exactly parallel to one another Front ...

Page 7: ...s later If a controller is inserted into a different location a system power on failure may occur NOTICE 2f Optional Installing disk modules If disks have not been installed into the storage devices install the disks before installing the storage devices To ensure high performance for heat dissipation insert disks in the sequence of disk slot IDs If the disk module is not fully configured cover fi...

Page 8: ...e OceanStor Dorado3000 V3 Dorado5000 V3 and Dorado6000 V3 V300R002 Installation Guide 3c 3d 3e 3f and 3g in the figure map to the sections respectively Section 3c is inapplicable to Dorado5000 V3 NVMe V300R002C00 while section 3e is inapplicable if no Dorado NAS unit is used The following figure uses AC power modules as an example to describe cable connection 3b Optional Connecting ground cables ...

Page 9: ...port EXP1 of each controller enclosure must be connected to port P0 and port P1 of disk enclosure 0 instead of different disk enclosures Port P0 and port P1 of the 12 Gbit s SAS interface module of each controller enclosure must be connected to port P0 and port P1 of disk enclosure 1 instead of different disk enclosures Each controller connects to ports P0 and P1 of a disk enclosure via two cables...

Page 10: ...Each controller connects to port P0 of a disk enclosure via one cable That is each controller enclosure connects to a disk enclosure via two cables Controller enclosure Connecting SAS disk enclosures to Dorado3000 V3 and Dorado5000 V3 Enhanced Edition SAS ...

Page 11: ...es A PCIe port can only connect to one disk enclosure Each controller connects to port P0 of a disk enclosure via one cable That is each controller enclosure connects to a disk enclosure via two cables The following shows the appearance of the PCIe cable mini SAS HD 8X It has two connectors at each end Controller enclosure PCIe cable mini SAS HD 8X ...

Page 12: ... details such as cable appearance and types of interface modules may be different from those at your site Dorado3000 V3 supports the following types of front end ports 8 Gbit s 16 Gbit s or 32 Gbit s Fibre Channel 10GE 25GE 40GE and 100GE Dorado5000 V3 NVMe and Dorado5000 V3 Enhanced Edition SAS support the following types of front end ports 8 Gbit s 16 Gbit s or 32 Gbit s Fibre Channel 10GE 10 Gb...

Page 13: ... between the Dorado NAS unit controller enclosure and application server For more topologies see the OceanStor Dorado3000 V3 Dorado5000 V3 and Dorado6000 V3 V300R002 Installation Guide The following figures are an example of cable connections The details like cable appearance and types of interface modules may be different from those at your site Direct attached connection between the Dorado NAS u...

Page 14: ...Maintenance terminal AC power modules enable the storage system to connect to two power supplies To ensure high availability of the storage system and avoid unexpected power failures connect the storage system to two power supplies 3g Connecting power cables Controller enclosure External power Complete view of the AC power cables A controller enclosure is used as an example The connections for dis...

Page 15: ... connections for disk enclosures and NAS units are similar When you connect DC power cables ensure that the black cable leading from the anode of the DC power source connects to the RTN terminal and that the blue cable leading from the cathode of the DC power source connects to the NEG terminal Controller enclosure DC PDU 15 ...

Page 16: ...he black cable connects to the NEG terminal 4 Checking Hardware Installation 5 Powering On the Storage System To avoid electric shock do not wear an ESD wrist strap when the storage system is powering on Do not change cable connections between enclosures after power on Otherwise the storage system may malfunction If the expansion cables are incorrectly connected power off the device reconnect the ...

Page 17: ...ndicator of the disk module off If NAS units are configured use the same method to check their indicators When checking disk indicators you only need to check the disks in slots 0 to 3 on the NAS units For details about indicators and troubleshooting suggestions refer to the OceanStor Dorado3000 V3 Dorado5000 V3 and Dorado6000 V3 V300R002 Product Description NOTICE 5d Installing front panels Alarm...

Page 18: ...nce terminal 2 Log in to the CLI of the storage system using remote login software such as PuTTY and set Speed to 115200 3 Run the change system management_ip command to change the IP address of the management network port 4 Log in to OceanStor DeviceManager on the maintenance terminal using the IP address of the management network port a Run Internet Explorer on the maintenance terminal b In the ...

Page 19: ...product information self service platform https enterprise huawei com topic Self_service_2013_en knowledge html Appendix Information about the default IP address of the storage system is shown as follows Storage Device Management Network Ports Default IP Address Utility of the IP Address IP Address Setting Method Controller enclosure management network ports on controllers A 192 168 128 101 You ca...

Reviews: