M.2 FRU Indicators
Figure 10-13
M.2 FRU indicators
Table 10-6
M.2 FRU indicator description
Indicator
Description
M.2 FRU fault indicator
l
Off: The M.2 FRU is running properly.
l
Blinking yellow: The M.2 FRU is being located, or RAID
is being rebuilt.
l
Steady yellow: The M.2 FRU is faulty or not detected.
M.2 FRU activity
indicator
l
Off: The M.2 FRU is not in position or is faulty.
l
Blinking green: Data is being read, written, or
synchronized.
l
Steady green: The M.2 FRU is inactive.
NVMe SSD Indicators
Figure 10-14
NVMe SSD indicators
l
If the VMD function is enabled and the latest Intel RSTe driver is installed, NVMe SSDs
support surprise hot swap.
Table 10-7
NVMe SSD indicators (VMD enabled)
Green Indicator
Yellow Indicator
Description
Off
Off
The NVMe SSD cannot be detected.
Steady green
Off
The NVMe SSD is working properly.
Blinking green at 2
Hz
Off
Data is being read from or written to the
NVMe SSD.
Off
Blinking yellow at
2 Hz
The NVMe SSD is being located.
FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
10 Hardware Description
Issue 06 (2019-08-10)
Copyright © Huawei Technologies Co., Ltd.
134