NVMe Drive Indicators
Figure 5-34 NVMe drive indicators
Table 5-18 NVMe drive indicators
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and
operating properly.
Blinking at 2 Hz
Off
Data is being read from or written to
the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The NVMe drive has completed the
hot swap process and is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
M.2 FRU Indicators
The server supports the Avago SAS3004iMR RAID controller card, which supports
two M.2 FRUs.
Figure 5-35 M.2 FRU indicators
Huawei FusionServer Pro 2488H V6 Server
Technical White Paper
5 Hardware Description
Issue 03 (2021-02-01)
Copyright © Huawei Technologies Co., Ltd.
55