● When a single fan is faulty:
●
The maximum operating temperature is 5°C (41°F) lower than the rated value.
●
System performance will be affected if GPU cards are configured.
● If V100 GPU cards are configured:
●
The maximum operating temperature is 30°C (86°F) in the 8 x 2.5" drive pass-
through configuration.
●
V100 GPU cards are not supported in the 12 x 3.5" and 24 x 2.5" drive pass-
through configurations.
●
V100 GPU cards are not supported in the 12 x 3.5" and 25 x 2.5" drive EXP
configurations.
● If T4 GPU cards are configured:
●
The maximum operating temperature is 35°C (95°F) in the 8 x 2.5" drive pass-
through configuration.
●
The maximum operating temperature is 30°C (86°F) in the 12 x 3.5" and 24 x 2.5"
drive pass-through configurations.
●
The maximum operating temperature is 30°C (86°F) in the 12 x 3.5" and 25 x 2.5"
drive EXP configurations.
● If OCP 2.0 mezzanine cards are configured:
●
The maximum operating temperature is 40°C (104°F) in the 8 x 2.5" drive pass-
through configuration.
●
The maximum operating temperature is 35°C (95°F) in the 12 x 3.5" and 24 x 2.5"
drive pass-through configurations.
●
The maximum operating temperature is 35°C (95°F) in the 12 x 3.5" and 25 x 2.5"
drive EXP configurations.
A.3 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can configure these features for better RAS.
For details about how to configure RAS features, see
Platform BIOS Parameter Reference
Table A-3 RAS features
Module
Feature
Description
CPU
Corrected Machine Check
Interrupt
Corrects error-triggered interruption.
DIMM
Failed DIMM Isolation
Identifies a faulty DIMM and isolates it
from others before it is replaced.
Memory Thermal
Throttling
Automatically adjusts DIMM
temperatures to avoid damage due to
overheating.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper
A Appendix
Issue 03 (2020-04-20)
Copyright © Huawei Technologies Co., Ltd.