Faulty DIMM isolation
●
Memory thermal throttling
●
Memory address parity protection
●
Memory demand/patrol scrubbing
●
Device tagging
●
Data scrambling
●
Adaptive double device data correction (ADDDC)
●
ADDDC+1
5.5 Storage
5.5.1 Drive Configurations
Table 5-8 Drive configurations
Configuration
Maximum Front Drives
Drive Management
Mode
4 x 3.5" drive
configuration
4
● Slots 0 to 3 support
only SAS/SATA drives.
1 x RAID controller
card/PCH
a
8 x 2.5" drive
configuration
8
● Slots 0 to 7 support
only SAS/SATA drives.
1 x RAID controller
card/PCH
a
10 x 2.5" drive
configuration 1
10
● Slots 0 and 1 support
only SAS/SATA drives.
● Slots 2 and 3 support
SAS/SATA/NVMe
drives.
● Slots 4 to 9 support
only NVMe drives.
1 x RAID controller
card/PCH
a
10 x 2.5" drive
configuration 2
10
● Slots 0 to 9 support
only SAS/SATA drives.
1 x RAID controller card
b
10 x 2.5" drive
configuration 3
10
● Slots 0 to 5 support
only SAS/SATA drives.
● Slots 6 and 7 support
SAS/SATA/NVMe
drives.
● Slots 8 and 9 support
only NVMe drives.
1 x RAID controller
card/PCH
a
Huawei FusionServer Pro 1288H V5 Server
Technical White Paper
5 Hardware Description
Issue 14 (2020-09-03)
Copyright © Huawei Technologies Co., Ltd.
29