Attribute
Alarm ID
Alarm Severity
Alarm Type
65547
Critical
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
OptModule
Index of the HFA
Case Temperature
Actual temperature of the HFA
Impact on the System
When the EDFA temperature is too high, the PUMP will be shut down.
Possible Cause
The ambient temperature is excessively high or the ventilation is poor.
Handling Procedure
Decrease the ambient temperature.
Alarm Clearing Condition
When the EDFA temperature decreases to the super high temperature alarm threshold minus
1, the alarm is cleared (hysteresis range: 1°C).
2.3.3 EDFA PUMP Alarms
2.3.3.1 ALM-65539 EDFA Pump1 Current Alarm
Description
When the current of EDFA PUMP1 exceeds the preset alarm threshold, this alarm is
generated.