Bare crimping terminals need to be crimped on both ends of the power cable. Terminals vary
according to different devices. The OT bare crimping terminals and JG2 double-hole bare
crimping terminals are usually adopted.
Figure 6-3
OT bare crimping terminal
Figure 6-4
JG2 double-hole bare crimping terminal
6.1.3 E8000E-X16 DC-Input Power Cable
CAUTION
If the power supply distance is longer than 35 m, you need to place the DC power distribution
cabinet near the E8000E-X16. For cables to be selected, see
.
You need to prepare suitable cables according to the surveyed power supply distance between
the E8000E-X16 and the power distribution cabinet.
Power Supply Distance Shorter Than or Equal to 15 m
If the power supply distance is shorter than or equal to 15 m, use the 16 mm
2
power cable to
connect the E8000E-X16 and the power distribution cabinet.
and cable types.
Table 6-1
Cables used when the power supply distance is shorter than or equal to 15 m
Item
Description
Cable type
NEG power
cable (-48 V)
Wire,450/750V,60227 IEC 02(RV)16mm
2
,blue,85A
HUAWEI Eudemon8000E Firewall
Hardware Description
6 Cables
Issue 01 (2012-11-07)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.