DA3100 Evaluation Sample User Manual V1.2
Security Level
2013-05-30
Huawei Proprietary - Restricted Distribution
Page3, Total12
3.3.
Configuration through SMS
Device can be configured via SMS commands. These commands are sent to the device
SIM number and the device will reply with an SMS response. Below are the
commands and responses.
i.
Set the APN according to the network carrier provided (Note: APN MUST be set
upon initialization of device usage. There is no default setting)
SMS Command:
+MTP:1000,<USN>,<PWD>,<NAME>
Response (via SMS):
Tips:APN UserName:<USN>,APN Password:<PWD>,APN
Name: <NAME> setting ok!
<USN>:
APN user name, blank if not applicable
<PWD>:
APN password, blank if not applicable
<NAME>:
APN name
ii.
Set the data upload time (default is 30 second)
SMS Command:
+MTP:1001,<TIME>
Response (via SMS):
Tips:MTP Report Period:<TIME> setting ok!
< TIME >:
upload time in seconds (min is 1 second)
iii.
Retrieve system parameters and status for settings confirmation
SMS Command:
+MTP:1002
Response (via SMS):
Tips:SoftVer:<VER>,APN UserName:<USN>,APN
Password:<PWD>,APN Name:<NAME>,IP:<IP>,PORT: <PORT>,Report Period:
< TIME >,Server Connect Status:OK!
<VER>:
software version, eg. V1.000.20130108
<USN>:
APN user name, blank if not applicable
<PWD>:
APN password, blank if not applicable
<IP>:
IP address, eg. 172.22.44.33 (Note: Huawei server IP address)
<PORT>:
Port number, eg. 12001 (Note: Huawei server port number)
<TIME>:
upload time in seconds
iv.
Set the heartbeat time (default is 1 second)
SMS Command:
+MTP:1004,<TIME>
Response (via SMS):
Tips:Heartbeat Period:<TIME> setting ok!
< TIME >:
heartbeat time in seconds