Power on the AP6010DN and check the indicator status to determine the
System running status.
NOTE
Power-on
Color
Frequency
Description
Type
Green
Green
0.5 Hz
Default status
Running
Steady on
The system is running properly, the Ethernet connection is
correct,and STAs are associated with the AP.
UBOOT:
The AP is just powered on.
Green
Red
Steady on
0.2 Hz
The system is running properly, the Ethernet connection is
correct, no user is connected, and the system is in low power
consumption state.
Alarm
4 Hz
1. The AP is being upgraded.
2. The CAPWAP tunnel is disconnected.
3. The AP is running properly, but does not go online.
Error
A fault that affects services occurs and cannot be rectified
automatically. For example, the system fails to load the DRAM or
system software. The fault needs to be rectified manually.
Technical Specifications
50mm×180mm×180mm
400g
Item
Description
Dimensions (H x W x D)
Weight
12 V DC (Power adapter)
Output: DC 12V ±10%
Input: 100V ~240V AC
Operating temperature
-10
℃
to +50
℃
Relative humidity
10% to 95%
Altitude
Pressure
70kPa to 106kPa
PoE power
-48V
–60 m to 4000 m
7