NOTE
l
Before fixing the adjustable buckle with a screw, adjust the buckle to a proper position based on the
T-rail width.
l
Ensure that the AP is correctly installed on the mounting bracket and there is 200 mm space above
and around the AP for maintenance.
l
In a scenario with heavy vibrations, tighten the AP to the mounting bracket using M4x30 screws
with a torque of 1.4N•m. This prevents the AP falling off from due to vibrations. In normal
scenarios, you do not need to install these screws.
2.6.4 Removing an AP
Flip the spring clip on the mounting bracket and slip the AP towards the spring clip. Release
the spring clip until the rubber feet of the AP enter the mounting keyholes. Remove the AP
from the mounting bracket.
Figure 2-4
Removing an AP
a
b
c
NOTE
If a captive screw is installed, remove the screw and then follow the preceding steps to uninstall the AP.
2.7 Cable Connection
describes the cable connections.