Figure 2-2
Space requirements for installing an AP8182DN (unit: mm)
≥500
≥1000
≥500
≥200
≥200
When determining the AP installation position, comply with the following rules:
l
Do not install the AP in the place with high temperature, dust, noxious gas, or unstable
voltage, or in the place near flammable or explosive materials and interference sources
such as a large radar station, radio station, and transformer station.
l
Place the AP far away from electronic devices that may produce radio interference, such
as other APs, antennas, and other radio communication devices. For details, see
.
l
Install the AP in a hidden position that does not affect daily lives and work of residents.
l
Make the engineering design by fully considering such factors as hydrology, geology,
earthquake, electric power, and traffic. The selected site should comply with the
environment design specifications of communications equipment.
Table 2-3
General anti-interference requirements
Scenario
Deployment Distance Requirement
Outdoor
installation
l
If antennas are mounted to different poles in back-to-back mode, the
horizontal distance between them should be at least 1.5 m.
l
If antennas are mounted to the same pole facing the same direction,
the vertical distance between them should be at least 5 m.
l
The antennas should be placed at least 2 km away from the 4G
signal tower of the carrier.
AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
2 AP Installation
Issue 03 (2019-04-01)