2

MODELS:

 

HY3002 -2 

HY3003 -2

HY3005 -2

HY3002 -3 

HY3003 -3 

HY3005 -3 

HY3002D-2 

HY3003D-2

HY3005D-2

HY3002D-3

HY3003D-3 

HY3005D-3

MODEL 

HY3002F-2 

HY3003F-2

HY3005F-2

HY3002F-3

HY3003F-3 

HY3005F-3 

OUTPUT 

VOLTAGE 

2×0-30V 2×0-30V 2×0-30V 2×0-30V 2×0-30V 2×0-30V 

OUTPUT 

CURRENT 

2×0-2A 2×0-3A 2×0-5A 2×0-2A 2×0-3A 2×0-5A 

FIXED 

OUTPUT 

NO 

NO 

NO 

5V, 3A 

5V, 3A 

5V, 3A 

 

MODEL 

HY5003E-2  HY5003E-3 

HY5005E-2  HY6005E-2  HY6003E-3  HY3010E-2  HY3010E-3 

OUTPUT 

VOLTAGE 

2×0-50V 2×0-50V 2×0-50V 2×0~60V

2×0~60V

2×0~30V 2×0~30V

OUTPUT 

CURRENT 

2×0-3A 2×0-3A 2×0-5A 2×0~5A 2×0~3A 

2×0~10A 

2×0~10A

FIXED 

OUTPUT 

NO 

5V, 3A 

NO 

NO 

5V, 3A 

NO 

5V, 3A 

 

 

Summary of Contents for HY3000-2 Series

Page 1: ...USER S MANUAL DC REGULATED POWER SUPPLY...

Page 2: ...output voltage is the sum of twice the voltage value in series mode and the highest output current is the sum of twice the current value when in parallel mode HY3000F 2 HY3000F 3 series have four LED...

Page 3: ...E 2 0 30V 2 0 30V 2 0 30V 2 0 30V 2 0 30V 2 0 30V OUTPUT CURRENT 2 0 2A 2 0 3A 2 0 5A 2 0 2A 2 0 3A 2 0 5A FIXED OUTPUT NO NO NO 5V 3A 5V 3A 5V 3A MODEL HY5003E 2 HY5003E 3 HY5005E 2 HY6005E 2 HY6003E...

Page 4: ...0mVr m s I 3A CC 6mAr m s I 3A 1 2 4 Protection constant current or short circuit protection 1 2 5 Voltage indication accuracy LED LCD 1 2digits analogue display 2 5 1 2 6 Current indication accuracy...

Page 5: ...nt adjustment of master output 7 Voltage adjustment of slave output 8 Current adjustment of slave output 9 Constant voltage mode indicator light for master output 10 Constant current mode indicator li...

Page 6: ...1 2 For constant voltage mode adjust controls 6 8 clockwise to the maximum position Move switches 2 3 to the voltage display position Switch on the power ON OFF switch and adjust controls 5 7 to the d...

Page 7: ...ed output voltage level connect the variable load to the output terminals 15 with 17 and 18 with 20 respectively then adjust the load to set the output current at the desired level for restricted curr...

Page 8: ...ge identically 2 2 3 2 In parallel mode the output current is adjusted by the master control 6 and slave control 8 has no effect The maximum output current is the sum of the master and slave output cu...

Page 9: ...8 4 ACCESSORIES 4 1 Power cord one piece 4 2 Instruction manual one piece...