HTW X6PW Owner'S Manual Download Page 6

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket
    with even strength, and pull it 
    out from the unit.

There are three ways to remove collected water.
1. Use the bucket

    

When the unit is off,if the bucket is full, the Full indicator

     light will light.
     When the unit is on,if the bucket is full, the compressor
     and the fan turn off, and the Full indicator light will light, 
     the digital display shows P2.
     Slowly pull out the bucket. Grip the left and right 
     handles securely, and carefully pull out straight so 
     water does not spill. Do not put the bucket on the floor 
     because the bottom of the bucket is uneven. Otherwise 
     the bucket will fall and cause the water to spill.
     Throw away the water and replace the bucket. The 
     bucket must  be in right place and securely seated  for the 
     dehumidifier to operate.
     The machine will re-start when the bucket is restored
     in its correct position.

Fig.5

Fig.6

OPERATING  THE  UNIT

3. Pour the water out.

NOTES:

    When you remove the bucket, do not touch any parts 
     inside of the unit. Doing so may damage the product.
     Be sure to push the bucket gently all the way into the 
     unit. Banging the bucket against anything or failing to 
     push it in securely may cause the unit not to operate.
     If the pump hose drops when you remove the bucket 
     (see Fig.7),you must reinstall the pump hose properly 
     to the unit before replace the bucket into the unit 
     (see Fig.8).     
     When you remove the bucket,if there is some water in
     the unit you must dry it.
     When the unit is on, if the bucket is removed, the 
     compressor and the fan turn off, then the unit will beep
     8 times and the digital display shows Eb. 
     When the unit is off, if the bucket is removed, the unit 
     will beep 8 times and the digital display shows Eb.

2. Continuous draining

Water can be automatically emptied into a floor 
drain by attaching the unit with a water hose
(Id

   5/16 , not included) with a female threaded

end (ID:M=1  , not included)
NOTE: On some models, the female threaded
end is included

8

    

 

    Remove the plastic cover from the back drain outlet of 
    the unit and set aside, then insert the drain hose through 
    the drain outlet of the unit and lead the drain hose to
    the floor drain or a suitable drainage facility. (See.Fig.9
    and Fig.10)
    When you remove the plastic cover, if there is some 
    water in the back drain outlet of the unit you must dry it.
    Make sure the hose is secure so there are no leaks and
    the end of the hose is level or down to let the water flow
    smoothly.
    Direct the hose toward the drain,making sure that
    there are no kinks that will stop the warter flowing.
    

Fig.9

NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet,
and dry the water in the continuous drain hose outlet.

Fig.7

Fig.8

Pump hose
drops

Reinstall pump 
hose properly

Fig.10

Remove the
plastic cover
by couter-clockwise
rotation.

    
    
    Select the desired humidity setting and fan speed on the 
    unit for continuous draining to start.

Drain hose

Removing the collected water

3. Pump draining (on some models)

Water can be automatically emptied into a floor 
drain or a suitable drainage facility by attaching 
the pump drain out with a pump drain hose 
(   od=1/4  , supplied).

    Remove the continuous drain hose from the unit and install 
    the plastic cover to the continuous drain hose outlet of the 
    unit by clockwise rotation.(See Fig.11)

  

    Resert the pump drain hose into the pump drain hose
    outlet for depth of 15mm at least (See Fig.11), then lead 
    the water hose to the floor drain or a suitable drainage facility.    
    Press the pump pad of the unit to activated the pump
    operation. When the bucket is full the pump starts to work.
    NOTE: The pump may cause big noise when it starts to 
                work for 3~5 minutes. It is a normal phenomenon.
    Make sure the hose is secure so there are no leaks.
    Direct the hose toward the drain,making sure that there 
    are no kinks that will stop the warter flowing.
    Place the end of the hose into the drain and make sure
    the end of the hose is level or down to let the water flow
    smoothly.Do never let it up.
    Select the desired humidity setting and fan speed on the 
    unit for pump draining to start. 

Pump drain
hose

Pump drain
hose outlet

NOTE: The pump operation on light blinks at 1Hz when the 
pump is operational failure. Please turn off the unit and plug 
the power cord out. Check the following things:

    Cleaning the filter of the pump.
    -Remove the bucket from the unit, take down the pump 
     and clean the filter of the pump (See Fig.12). 
    

Filter of the pump

    Check that the pump drain hose does not link or block.  
    

    

Fig.12

    Empty the water of the bucket.
    Reinstall the pump hose if it drops and reinstall the bucket 
    properly. Turn on the unit. If the error repeats, call for service. 
    
    
    
    
    

OPERATING  THE  UNIT

NOTE: Do not use this operation when the outdoor temperature

O

O

is equal to or less than 0 C (32 F), otherwise water is become
ice that will cause the water hose blocked up and the unit failure. 
Make sure to empty the bucket once a week when using
the pump draining feature. When the pump draining feature is 
not being used, remove the pump drain hose from the outlet.

2,Take the pump 
drain hose out

1,Press the pump drain
hose outlet in

   Press the pump drain hose outlet in and take the pump drain hose 
   out from it (See Fig.13). Make sure do not let the water in the pump 
   hose drip to the floor.   
    

    

Fig.11

Reinstall the
plastic cover

Fig.13

9

Female threaded
end

Summary of Contents for X6PW

Page 1: ...OWNER S MANUAL DESHUMIDIFIER X6PW HTWDB40X6PW HTWDB50X6PW Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Page 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troublesho...

Page 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take sp...

Page 4: ...Up Down pads to set the Auto start and Auto stop time from 0 0 to 24 The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH Relative Humidity in 5 increments For drier air pr...

Page 5: ...over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storag...

Page 6: ...hen the continuous draining feature is not being used remove the drain hose from the outlet and dry the water in the continuous drain hose outlet Fig 7 Fig 8 Pump hose drops Reinstall pump hose proper...

Page 7: ...pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull fi...

Page 8: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com www htwspain com...

Reviews: