MAINTENANCE
Maintenance activities
In order to ensure an optimum operation of the unit, a number of checks and inspections on the unit
and the field wiring have to be carried out at regular intervals, preferably yearly.
Check the water supply and air vent frequently, to avoid lack of water or air in the water loop.
Clean the water filter to keep a good water quality. Lack of water and dirty water can damage
the unit.
Keep the unit in a place where it is dry and clean, and which has good ventilation. Clean the
heat exchanger every one to two months.
Check each part of the unit and the pressure of the system. Replace the defect part if there is
any, and recharge the refrigerant if it is required.
Check the power supply and the electrical system, make sure the electrical components are
good, and the wiring is well. If there is a damaged part or a strange smell, please replace it in
time.
If the heat pump is not used for a long time, please drain out all the water from the unit and seal
the unit to keep it good. Please drain the water from the lowest point of the boiler to avoid
freezing in winter. Water recharge and full inspection on the heat pump is required before it is
restarted.
Do not turn the power ‘OFF’ when you use the unit continuously, or the water in the pipe will
freeze and split the pipe.
Keep the unit clean by means of soft damp cloth, no maintenance is required by the operator.
It is recommended to clean the tank and e-heater regularly to keep an efficient performance.
It is recommended to set a lower temperature to decrease the heat release, prevent scale
and save energy if the outlet water is sufficient.
Clean the air filter regularly to keep an efficient performance.
33
Summary of Contents for VAW 100L
Page 2: ......
Page 3: ...MANUAL DE USUARIO E INSTALACI N ESPA OL ACUMULADOR AEROT RMICO VAW HTW AT O 100VAW...
Page 4: ......
Page 40: ...DIAGRAMA DE CABLEADO Consulte el diagrama de cableado de la caja el ctrica 36...
Page 44: ......
Page 45: ...OWNER S AND INSTALLATION MANUAL ENGLISH SANITARY WATER HEAT PUMP VAW HTW AT O 100VAW...
Page 46: ......
Page 53: ...OVERVIEW OF THE UNIT Parts anddescriptions 7...
Page 81: ...WIRING DIAGRAM Please refer to the wiring diagram on the electric box 35...
Page 86: ......
Page 121: ...DIAGRAMME DE C BLAGE Veuillez vous r f rer au sch ma de c blage sur le bo tier lectrique 35...
Page 125: ...MANUAL DO UTILIZADOR E INSTALA O PORTUGU S BOMBA DE CALOR GUA SANIT RIA VAW HTW AT O 100VAW...
Page 126: ......
Page 162: ...DIAGRAMA DE FILA O Consultar o diagrama da cablagem da caixa el ctrica 36...
Page 166: ......
Page 167: ...MANUALE UTENTE E INSTALLAZIONE ITALIANO ACCUMULATORE AEROTERMICO VAW HTW AT O 100VAW...
Page 168: ......
Page 207: ......