background image

13 

Installation & Operation Manual 

0.5 

1.5 

2.5 

3.5 

4.5 

-15 -7  -2  0  2  7  15 20 25 30 32 35 40 43 

-15 -7  -2  0  2  7  15 20 25 30 32 35 40 43 

RSJ-100/N1-540V-D

COP curve of unit 

Ambient temperature(

°C

COP

W/W

Fig.9-5

Ambient temperature(

°C

10 

11 

12 

13 

14 

15 

Capability

kW

RSJ-100/N1-540V-D

capability  curve of unit 

Fig.9-6

Summary of Contents for RSJ Series

Page 1: ...OWNER S AND INSTALLATION MANUAL HEAT PUMP Thanks for choossing our product Please read carefully this manual before using the product ENGLISH 1H HTW RSJ420SZN1H...

Page 2: ...depand on model The actual shaped shall prevail Air inlet 3 faces Water inlet Scupper Water outlet Scupper RSJ 100 N1 540V D RSJ 200 SN1 540V D Air outlet High presure Connector Low presure Connector...

Page 3: ...CTRIC CONNECTION OF THE UNIT INSTALLING OPTIONAL FITTINGS OF THE UNIT SPECIFICATIONS PARAMETERS OF THE UNIT OPERATION AND PERFORMANCE OF WATER HEATER TRIAL RUN TROUBLESHOOT OF ABNORMAL PHENOMENA 1 1 2...

Page 4: ...t Place where flammable gases or materials exist Place where acid or alkali gases evaporate Other special environments 4 1 Installation Confirm the model serial number and name to avoid mistaken insta...

Page 5: ...ly guard boards to the contacting surface After move onto installing site please comfirm the main unit are placed in horizontal 4 5 Installing multiple units As shown in the figure leave spacing of at...

Page 6: ...let Filter Filter Return pump Valve Water tank One way Valve Hot water outlet Hot water inlet Sent to the user Heat pump heating water 0 unit Heat pump heating water 1 unit Heat pump heating water 15...

Page 7: ...5 DN65 9 12 13 14 15 16 DN80 DN65 DN80 DN80 DN65 DN80 Table 5 2 5 4 Selecting the inlet outlet pipelines of the RSJ 200 SN1 540V D model CAUTION Water heater shall have a specialized power supply whic...

Page 8: ...6 6 4 signal wire wiring Junction box b Water heater Ground wire Water heater Ground wire Water heater Ground wire Water heater Ground wire Water heater Ground wire Water heater 6 Installation Operat...

Page 9: ...ault and the compressor starts up normally y l t c e r i d RSJ 380 SN1 820 D electric wiring diagram 0 0 h t i w e t a c i n u m m o C s t i n u r e h t o h t i w e t a c i n u m m o C r e l l o r t n...

Page 10: ...ity of units connected in parallel 15 18 15 18 15 18 RSJ 100 N1 540V D Flow rate m3 h Lift m Flow rate m3 h Lift m RSJ 200 SN1 540V D RSJ 380 SN1 820 D 1 2 1 5 2 3 2 15 18 15 18 15 18 2 4 3 4 6 4 5 8...

Page 11: ...nt A Operation control Working substance Charged volume Water circulate param Mode Model Diam of water outlet pipe Factory settingtemperature 56 C Adjustable range 48 60 C Testing conditions Outdoor a...

Page 12: ...ce will act when the following circumstances occur Air inlet or outlet are blocked Air in water or refrigerant system exhaust incompletely Voltage is a little higher or lower compare to the voltage ra...

Page 13: ...ig 9 1 RSJ 380 SN1 820 D 0 1 2 3 4 5 6 15 7 2 0 2 7 15 20 25 30 32 35 40 43 COP W W COP curve of unit Ambient temperature C Fig 9 2 0 10 20 30 40 50 60 15 7 2 0 2 7 15 20 25 30 32 35 40 43 Ambient tem...

Page 14: ...2 5 3 3 5 4 4 5 5 15 7 0 2 7 10 15 20 25 30 32 35 40 43 COP W W Ambient temperature C COP curve of unit Fig 9 4 6 8 10 12 14 16 18 20 22 24 26 28 15 7 0 2 7 10 15 20 25 30 32 35 40 43 Ambient tempera...

Page 15: ...2 0 2 7 15 20 25 30 32 35 40 43 15 7 2 0 2 7 15 20 25 30 32 35 40 43 RSJ 100 N1 540V D COP curve of unit Ambient temperature C COP W W Fig 9 5 Ambient temperature C 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Page 16: ...mories the operation status before power failure and records the Time Switch ON signals Other information are return to default values after power be supplied again Due to the signal of Time Switch ON...

Page 17: ...tersale service centre 1 ON OFF operation is ineffective 2 Fuse or RCCB is frequently broken PHENOMENA CAUSE Table 11 1 Not distribute to malfunction Please check that again White aerosol or globule i...

Page 18: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com www htwspain com...