– 7 –
PART 3:
The Installation of Heat Pump
■ Basic Installation Tools and Materials Needed
■ Installation Instructions
1. Machine Moving
● This machine is quite heavy so that it requires two or more people to move and install, or it
may cause in personal injury or other accidents.
● Please transfer the machine as its delivery status, do not disassemble it by yourself.
● In order to avoid scratches and deformation on the surface, please add protection board
over the surface of the machine which may contact hard objects directly.
● Be careful not to touch the wind vane with your hands or other objects.
● Do not transfer the machine as the inclination is over 45°. Do not lay down the machine
recumbently on the floor.
2. Installation Location Selection
● The machine should be installed in the room.
● Please choose the location which can bear the heat pump’s weight, will not cause much
vibration and noise when hanging on it, and have good ventilation. The air outlet place
should avoid facing the wind direction and remain the horizontal line place. If the machined
is installed in the place vulnerable to rain, it is essential to take the necessary measures to
prevent rain and avoid rain erosion.
● Please select the place where easily connecting to the water pipes and electric power suply.
● Please select the place where water can successfully exhaust out of the relief valve when it works.
● Please select the place where water exhausted out of the relief valve will not splash on the
wood floor or furniture.
● When installing, please leave space for installation and maintenance shown as the below
drawings. There should be no obstacles at the machine’s wind outlet within the range of
600mm.
● When install the heater, the inclination should not more than 5°.
NAME
QTY
Usage
Pipe wrench
2 pcs
To connect the water pipes.
Straight screwdriver
Phillips screwdriver
1 pc per each
To disassemble the battery box
and connecting wires.
Wire scissor / stripper
1pc
To trim thread and strip wire.
Percussive drill/wrench
1/2 pcs
To fix the machine’s anchor bolt.
Ball valve
1 pc
To install the tank inlet water pipes.
Water pipe, flexible joint
Depends on the actual need.
PPR pipes, PAP pipes.
Hot water pipe
insulation material
Depends on the length of the
heat pipe.
To insulate.
Summary of Contents for HTW-AT-O-200VA1
Page 23: ...23...