HTP Superstor Pro 100 Installation, Start-Up And Maintenance Instructions Download Page 9

lp-451 Rev. 001 Rel. 001 Date 7.25.17

9

Figure 7 - Thermostat Connection

Part 4 - Heater Control and Wiring

A. Control

A surface mount thermostatic control has been provided for accurate 

temperature adjustment.

B. Wiring

Wiring is to be done in accordance with all applicable local and state 

codes. Turn off all power related to the boiler before starting any 

wiring procedures. It is recommended that a disconnect switch be 

installed between the boiler control and the water heater.

When wiring the water heater and controls be sure to label all wires 

to ease future maintenance. Wiring errors can cause improper and 

dangerous operation.

A thermostat connection has been provided on the top of the water 

heater for easy wiring and accurate control. See Figure 7. Connect the 

wires from the thermostat to the terminals (Positive) or - 

(Negative).

POSITIVE

NEGATIVE

LP-451-H

03/29/17

C. Wiring Diagrams

Figure 8 - Wiring with Circulators

Figure 9 - Wiring with Zone Valves

Summary of Contents for Superstor Pro 100

Page 1: ...o so could result in substantial property damage severe personal injury or death HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical...

Page 2: ...With Local state provincial and national codes laws regulations and ordinances Part 1 General Safety Information This water heater is approved for indoor installations only and is not intended for use...

Page 3: ...d as safe GRAS and having a toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Products 5th edition Ensure the system is permanently labeled to indicate any additives used in...

Page 4: ...d associated equipment Water quality must be professionally analyzed to determine whether it is necessary to treat the water Various solutions are available to adjust water quality Adverse water quali...

Page 5: ...7 ACCESS COVER 40 50 60 80 100 MODELS BOILER IN THERMOSTAT BOILER OUT D C A B E DRAIN VALVE BOILER IN B A C D TOP VIEW 100 80 60 50 40 30 100 80 60 50 40 30 BOILER OUT 266 155 000 10 GPM 2 3 FT 111 LB...

Page 6: ...o any system that uses glycol or other solutions formulated for hydronic systems These auxiliary connections are to be used only in a potable water system Failure to follow this warning could result i...

Page 7: ...death due to scalds This water heater can deliver scalding water Be careful whenever using hot water to avoid scalding injury Certain appliances such as dishwashers and automatic clothes washers may r...

Page 8: ...PIPING NOTES The following notes are applicable to all of the piping applications demonstrated on this page 1 Minimum pipe size should match connection size Upsize pipe accordingly if greater flow is...

Page 9: ...ecommended that a disconnect switch be installed between the boiler control and the water heater When wiring the water heater and controls be sure to label all wires to ease future maintenance Wiring...

Page 10: ...ing the cold water shut off valve Make certain the field installed drain valve is completely closed Purge air from the system by opening a hot water outlet at a fixture in a kitchen or bathroom When w...

Page 11: ...connections Make sure they are tight Relief and Drain Valve Relief Valve Lift and release the relief valve on the water heater Make certain that the valve operates properly by allowing several gallon...

Page 12: ...Recheck Not enough space heat Boiler sized too small Consult chart Slow recovery Circulator head capacity too low T P Valve Discharges Hot Tubs Spas Multiple Showers High Demand Problem Possible Solut...

Page 13: ...istration the warranty period for the water heater shall then be deemed to have commenced thirty 30 days from the date of manufacture of the water heater and NOT the date of installation of the water...

Page 14: ...ranty contact the retailer from whom the water heater was purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of the original receipt complete model...

Page 15: ...omer s Name Date of Installation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Plea...

Reviews: