                                                                                        LP-04 REV. 4.15.14 

 

 

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk 
levels, or to important product information. 

 

 

DANGER

 indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. 

 

 

WARNING

 indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. 

 

 

CAUTION

 indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. 

 

 

CAUTION

 used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property 

damage. 

FOREWORD 

This manual is intended to be used in conjunction with other literature provided with the electric water heater. This includes all related 
control information. It is important that this manual, all other documents included with this system, and additional publications be 
reviewed in their entirety before beginning any work. 
 
Installation should be made in accordance with the regulations of the Authority Having Jurisdiction, local code authorities, and utility 
companies which pertain to this type of water heating equipment. 

FOR THE INSTALLER 

 
This water heater must be installed by qualified and licensed personnel. The installer should be guided by the instructions furnished 
with the water heater, and with local codes and utility company requirements. 
 

INSTALLATIONS MUST COMPLY WITH: 
 

Local, state, provincial, and national codes, laws, regulations and ordinances. 
 
The latest version of the 

National Electrical Code, NFPA No. 70

TABLE OF CONTENTS

 

PART 1 

– GENERAL SAFETY INFORMATION .......................................................................................................................... 3

 

A. PRECAUTIONS .......................................................................................................................................................................... 3

 

B. WHEN SERVICING THE WATER HEATING SYSTEM .............................................................................................................. 4

 

C. HEATER WATER ....................................................................................................................................................................... 4

 

D. INSTALLATIONS IN THE STATE OF CALIFORNIA .................................................................................................................. 4

 

E. WATER CHEMISTRY ................................................................................................................................................................. 4

 

PART 2 

– PREPARE THE WATER HEATER ............................................................................................................................. 4

 

A. SPECIFICATIONS AND PERFORMANCE RATINGS ................................................................................................................ 5

 

 

This manual must only be used by a qualified heating installer/service technician. Read all instructions in this manual before installing. 
Perform steps in the order given. Failure to comply could result in substantial property damage, severe personal injury, or death. 

Summary of Contents for Everlast EV-12

Page 1: ...oduct contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and w...

Page 2: ...rety before beginning any work Installation should be made in accordance with the regulations of the Authority Having Jurisdiction local code authorities and utility companies which pertain to this ty...

Page 3: ...ble materials 0 top bottom sides and back Heater must have room for service 24 front and 6 sides are minimum recommended service clearances A combustible door or removable panel is acceptable front cl...

Page 4: ...CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult...

Page 5: ...22 27 19 41 EV 30 30 4500 240 4 34 39 19 55 EV 30LB 30 4500 240 4 21 28 23 65 EV 45LB 45 4500 240 4 34 42 23 86 EV 50 50 4500 240 4 56 63 19 1 90 EV 80 80 4500 240 5 64 72 23 1 132 Table 1 Specificat...

Page 6: ...result in substantial property damage severe personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to th...

Page 7: ...testing laboratory that maintains periodic inspection of production of listed equipment and materials Install the T P valve into the opening provided and marked for this purpose on the water heater so...

Page 8: ...cold and hot water in branch supply lines Such valves are available from your local plumbing supplier Table 2 details the relationship of water temperature and time with regard to scald injury and ma...

Page 9: ...REV 4 15 14 F INSTALLATION DIAGRAMS Figure 3 Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by loca...

Page 10: ...V 4 15 14 Figure 4 Mobile Home and Point of Use Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by l...

Page 11: ...the 120 volt model the white wire must be connected to the neutral leg 240V electrical installation should be done by a qualified licensed electrician or by your local electric utility All wiring mus...

Page 12: ...protective cover should NOT be removed Set temperature indicator to desired temperature Replace insulation and the black access cover Turn on power to the heater See below for Thermostat adjustment E...

Page 13: ...Screw the element clockwise into tank and tighten with the 1 socket wrench Be sure O ring seats properly STEP 6 Refill the tank with cold water STEP 7 Pressure check the tank for leaks around element...

Page 14: ...for assistance Check the area around the water heater for flammable liquids or combustible materials If any are found remove from the area Vacation Extended Shut Off Periods During extended mild or w...

Page 15: ...at 4 Manual Reset High Limit Switch ECO open a Thermostat s defective b Thermostat out of calibration c Heat build up due to loose wires d Defective High Limit Switch ECO 1 Turn switch ON 2 Rewire per...

Page 16: ...LECTRIC ELEMENT W O RING EV 6 EV 20 1 2 6060P 187 ELECTRICAL BOX COVER 2 3 TP1500 3 4 T P VALVE 100XL 8 1 4 6060P 633 THERMODISC MOUNTING CLIP 2 5 TD1015 UPPER THERMOSTAT CONTROL 1 6 6060P 1009 THERMO...

Page 17: ...17 LP 04 REV 4 15 14 NOTES...

Page 18: ...nstallation Address Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign afte...

Reviews: