background image

3. Introduction to “color palette” sub-menu

2.2. Delete images 

3.1.Color palette description

3.2.  Application of color palette 

When viewing the images, the screen will show the prompt of “Delete 
photo

” by pressing “           ” key. If “yes” is selected at the moment, 

press “        / MENU ” key to determine to delete the image. If “no” is 
selected, press “  SELECT/ENTER ” key to determine not to delete 
the image.

The following is the image of the same object with selection of different
color palettes.

As shown in the figure, press “       /MENU” key to enter the main menu 
and select “          ” (color palette) option and press “        ” key to enter 
the color palette list. Press   “         ” and “         ” keys in navigation to 
select the color palette. Then press “SELECT/ENTER ” key to select 
the color palette. Press “        ” to return. Press “       / MENU ” key to 
exit from the menu.

Spectra

Iron

Cool

White

Black

Color palette

The palette can be used to change the pseudo-color display of the 
infrared image on the display. Some tune
Swatches are better suited for specific applications and can be set 
up as needed. The palette is divided into: rainbow, iron red, cool, 
white hot, black hot, five palettes. These palettes work best with 
high thermal contrast and provide additional color contrast between 
high and low temperatures.
Suitable selection of color palette displays the details of the target 
objective better. Rainbow, iron oxide red and cold color palettes 
focus on display of color. Such color palettes are very suitable for 
high heat contrast and are used to improve the color contrast 
between high temperature and low temperature. But the black & 
white and white & black color palettes provide even linear color.

Iron oxide red

Rainbow

Cold color

White heat

Black heat

www.xintest.com.cn

21

www.xintest.com.cn

22

Summary of Contents for HT-A1

Page 1: ...2 Yuhua Street Hongye Industrial Zone Tangxia Town Dongguan City Guangdong Province Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hytechcn com cn www xintest com cn www xintest en alibaba com Email kevin xintest com cn User Manual Version 1 2 Revised March 5 2019 HT A2 HT A1 ...

Page 2: ...f image overlapping 1 2 Application of Image overlapping 2 Introduction to image sub menu 2 1 View image 2 2 Delete images 3 Introduction to color palette sub menu 3 1 Color palette description 22 23 24 25 26 27 27 29 27 27 27 30 28 23 3 2 Application of color palette 4 Introduction to emissivity sub menu 4 1 Emissivity description 4 2 Emissivity setting 4 3 The emissivity value of common material...

Page 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 7: ... professional optical glasses Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Page 8: ...nterface When the product is off you can charge www xintest com cn 11 www xintest com cn 12 Display screen Model HT A1 HT A2 Infrared image resolution Visible image resolution Field angle Shortest focus length Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette View option Storage medium File fo...

Page 9: ...orage temperature Relative humidity Built in chargeable 1800 battery Micro USB 2 0 Selectable 5 minutes 20 minutes not power off automatically 140mm 80mm 28mm 208g 0 to 45 20 to 60 85 RH working time 2 3 hours Visible light camera Infrared imaging sensor Image capture key LED lighting lamp Micro USB Back 320X240 English Chinese Italian German Setting command Language Unit language dat time informa...

Page 10: ...e screen area It will move with the movement of the lowest temperature The cursor displays red The temperature value is displayed at the central position of the screen www xintest com cn 15 www xintest com cn 16 On off key Menu key Selection key Entry key Navigation key Up down left and right The highest temperature cursor used to indicate the highest temperature position in the screen area It wil...

Page 11: ...cessful the screen will display store photo prompt If yes is selected please press MENU key to determine to save the image If no is selected press SELECT ENTER key to determine not to save the image Image output The saved images through capture may be checked and output by connecting with a computer through Micro USB Read images Open the USB protective cover as shown in Use USB line to connect the...

Page 12: ...t easier for users to understand the infrared images by using aligned visible images and infrared images The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly and share with other people more effectively 1 2 Application of Image overlapping Press the MENU button to enter the main menu and sele...

Page 13: ... exit from the menu Spectra Iron Cool White Black Color palette The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide a...

Page 14: ... less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivity will produce gia...

Page 15: ...lack rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile Substance Thermal radiation Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar Brick Press MENU key to select the setting option in the main menu Press key again to enter the setting sub menu If you select self defined emissivity press the SELECT ENTER button to ent...

Page 16: ...enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes As shown in the figure after selecting set time press in the navigation key to enter the setting time After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 24h Year Month Day Hou...

Page 17: ...tion Then press SELECT ENTER key to determine selection After the setting is completed press key to return Press MENU key to exit from the menu Spot Off On 24h Failure phenomenon The thermal imaging device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new batt...

Page 18: ...尺寸 9cm X 10cm 铜版纸 骑马钉 注意封面封底 必须对应首页跟尾页 ...