Conference set HT‐6800/HT‐9100 User manual
5
Rear panel :
7. AUX IN INPUT
Aux level type. Connect on this input a device with level line such as a cd player, a dvd player, a mixer,… This device will be diffused on
the speakers of all the micro connected to the system.
8. LINE
OUTPUT
This socket is used to connect an external sound system (power amplifier or 100v power amplifier). The conference is reproduced on a
system more powerfull
9. REC
OUTPUT
This output is used to record the conference. Connect on it a recording device as cd recorder or tape recorder
10. MASTER OUTPUT
This socket is used to connect an external sound system (power amplifier or 100v power amplifier). The conference is reproduced on a
system more powerfull
11. VIDEO DVD INPUTS
This system allows the display of video devices on the built-in touchsreen. Video can be movies from DVD player or video from cameras.
Connect on these inputs devices as DVD player, video ouput from computer,...
Device (DVD 1 or 2 inputs ) is selected directly from touchscreen display of main unit ( A = DVD 1, B = DVD 2 ).
12. MIC CONNECTORS
Use this connectors to connect all the mic. If you have more than 4 mic, you must to use connection box HT-D9100 (in option). You can
connect up to 32 mic
Note: Video & sound of the mic are in the same cable.
13. LINK OUTPUT
If you have more than 32 mic, use this connector to connect an additional power supply.
14. DATA CONNECTOR
Connect to this socket a video processor if you to control more than 4 camera
15. POWER SOCKET
Connect on this socket the power supply cable ( 220V )
The fuse is used to protect the main unit. If the fuse use is defect replace it by a fuse with same size and same value
16. CAMERA CONTROLE CONNECTOR
If you use dome in place of camera you can control pan and tilt move directly from software. Connect this socket to the control connector of
domes..
Note : To know connections, read the user manual of the dome.
XLR socket
1- GND
2- +
3- -
RS-485
1- RS-485A+
2- GND
3- RS-485B-
RJ-45e
1- GND
2- GND
3- RS-485A+
4- RS-485B-
5- NC
6- NC
7- GND
8- GND