1.  FOREWORD   

Solar meter: a device used to measure solar power.

 

Mainly applied for solar radiation measurement, solar power 

research, physics and optical laboratories, Identify high performance windows, Meteorological, Agricultural. 
 
Measurement: Expressed by W/m

2

 

or BTU (ft

2

 

*h). 

2.  SAFETY PRECAUTIONS AND PROCEDURES 

This instrument conforms with safety Standard EN 61010-1 related to electronic measuring instruments. 
For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual 
and read carefully all notes   
preceded by this symbol. 

 

 

CAUTION 

For your own safety and to avoid damaging the instrument follow the 

procedures described in this instruction manual and read carefully all 

notes preceded by this symbol 

When taking measurements: 

Be particularly careful when measuring voltages exceeding 20V to avoid risks of electrical shocks.   
Avoid doing that in humid or wet places. 
Avoid doing that in rooms where explosive gas, combustible gas, steam or excessive dust is present. 

 Keep you insulated from the object under test. 

Do not touch exposed metal parts such as test lead ends, sockets, fixing objects, circuits etc. 

 Avoid doing that if you notice anomalous conditions such as breakages, deformations, fractures, leakages of 

battery liquid, blind display etc. 

Summary of Contents for LX-107

Page 1: ...SOLAR POWER METER User s Manual...

Page 2: ...notes preceded by this symbol CAUTION For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this...

Page 3: ...ission through transparent and film glass Convenient no need to adjust data displayed clearly 5 FEATURES Super low price high precision Measurable light sources including all visible light Overload di...

Page 4: ...LCD DISPLAY SHOWS 1 Data hold 2 Peak hold 3 Decimal point 4 Numeral screen 5 W m2 6 BTU ft2 h 7 Low battery indicator 6 2 BUTTONS 1 Power button 2 Data Hold button 3 Lock up Peak 4 Auto Range 5 W m2...

Page 5: ...select a different unit Press the W m2 button to switch from Btu ft2 h to W m2 6 2 5 Data hold button Press the HOLD button to go into hold mode and HOLD appears on the screen to allow you to read the...

Page 6: ...of your house s windows Close the window Press the POWER button on your solar meter and 00 0 comes up on the screen Put the device close to the window and aim it at the sun Compare the value against...

Page 7: ...NEDA 1604 IEC 6F 22 JIS 006P 1 carrying case 8 SAFETY AND MAINTENANCE STANDARDS Operating altitude below 2 000m Operating environment for indoor use expose to pollution level II This is a precision d...

Page 8: ...agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in...

Page 9: ...ld you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing...

Reviews: