Usage
HTC 80 iD
16
1.1
1. Loosen the hose that sits on the bottom edge of the HEPA filter holder and runs
down to the side duct fan from the HEPA filter holder.
2. Loosen all quick fasteners holding the upper and lower cylinder sections
together, and then carefully tip the upper section towards the handle, see
Figure 4-2, page
Figure 4-2. Lower to the service position
Warning!
There is a risk for crush injuries when the dust extractor is lowered to the
service position. Make sure your hands are not in the way when the upper
cylinder sections tips against the handle.
Warning!
The dust that is sucked up is harmful if inhaled. Follow local regulations and
use breathing protection.
4.3
The positions for the pre-separator
Pull out the pin to make it possible to rotate the pre-separator to different positions.
Turn the pre-separator and release the pin to lock it in the desired position.