1. PRECAUTIONS AND SAFETY MEASURES 

The instrument has been designed in compliance with directive IEC/EN61010-1 relevant to 
electronic measuring instruments. For your safety and in order to prevent damaging the 
instrument, please carefully follow the procedures described in this manual and read all 
notes preceded by the symbol 

 with the utmost attention. 

 

Before and after carrying out the measurements, carefully observe the following 
instructions: 

  Do not carry out any voltage or current measurement in humid environments. 

  Do not carry out any measurements in case gas, explosive materials or flammables are 

present, or in dusty environments. 

  Avoid contact with the circuit under test if no measurements are being carried out. 

  Avoid contact with exposed metal parts, with unused measuring probes, circuits, etc. 

  Do not carry out any measurement in case you find anomalies in the instrument such 

as deformation, breaks, substance leaks, absence of display on the screen, etc. 

  Pay special attention when measuring voltages higher than 20V, since a risk of 

electrical shock exists 

 

In this manual, and on the instrument, the following symbols are used: 

 

 

Warning: observe the instructions given in this manual; an improper use could 
damage the instrument or its components. 

 

 

High voltage danger: electrical shock hazard. 

 

 

Double-insulated meter 

 

1.1. PRELIMINARY 

INSTRUCTIONS 

  This clamp has been designed for use in environments of pollution degree 2. 

  It can be used for 

VOLTAGE

 measurements on installations with measurement 

category CAT II 300V. For a definition of measurement categories, see § 1.4. 

  We recommend following the normal safety rules devised by the procedures for 

carrying out operations on live systems and using the prescribed PPE to protect the 
user against dangerous currents and the instrument against incorrect use. 

  Do not test circuits exceeding the specified current and voltage limits. 

  Check that the battery is correctly inserted. 

 

1.2. DURING 

USE 

Please carefully read the following recommendations and instructions: 

 

 

CAUTION 

 

Failure to comply with the Caution notes and/or Instructions may damage 
the instrument and/or its components or be a source of danger for the 
operator. 

 

  When the instrument is connected to the circuit under test, do not touch any unused 

terminal. 

  Don’t execute continuity test when external voltage is present. 

 

1.3. AFTER 

USE 

  If the instrument is not to be used for a long time, remove the batteries. 

Summary of Contents for HT5

Page 1: ... Copyright HT ITALIA 2012 Release EN 2 01 07 02 2012 ENGLISH User manual ...

Page 2: ...ERATING INSTRUCTIONS 5 4 1 Instrument description 5 5 INSTRUMENT FUNCTIONS 6 5 1 Phase detection 6 5 2 Lamp test 7 5 3 Continuity Diode test 8 6 MAINTENANCE 9 6 1 General information 9 6 2 Battery replacement 9 6 3 Cleaning the instrument 9 6 4 End of life 9 7 TECHNICAL SPECIFICATIONS 10 7 1 Technical characteristics 10 7 2 General characteristics 10 7 3 Environment 10 7 3 1 Environmental conditio...

Page 3: ...nt the following symbols are used Warning observe the instructions given in this manual an improper use could damage the instrument or its components High voltage danger electrical shock hazard Double insulated meter 1 1 PRELIMINARY INSTRUCTIONS This clamp has been designed for use in environments of pollution degree 2 It can be used for VOLTAGE measurements on installations with measurement categ...

Page 4: ...measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use and some other equipment for example stationary motors with permanent connection to fixed installation Measurement category II is for measurements performed on circuits directly connected to the low voltage installat...

Page 5: ... are found immediately contact the forwarding agent We also recommend checking that the packaging contains all components indicated in 7 4 In case of discrepancy please contact the Dealer In case the instrument should be replaced please carefully follow the instructions given in 8 2 3 2 INSTRUMENT POWER SUPPLY The instrument is powered by a single 9V battery type NEDA1604 JIS006P IEC6F22 included ...

Page 6: ...CAPTION 1 Test Probe for lamp test voltage test and continuity diode test 2 Test LED 3 Continuity Voltage LED 4 Touch electrode for voltage test and Continuity diode test 5 Button for lamp test 6 Button for torch light 7 Battery case Fig 1 Instrument description ...

Page 7: ...to the device under test Illumination of the LED Continuity Voltage indicates the presence of an AC voltage between 60V and 250V Simultaneously an acoustic sound is audible CAUTION A correct indication is only ensured for AC voltage circuits with a frequency of 40 60 Hz being grounded in accordance with the regulations The quality of the indication may be impaired when testing in unfavourable loca...

Page 8: ...ing low pressure sodium vapour tubes Test tube by contacting the socket pins with test probe and observe if the inner tube is glowing In some cases only part of the tube is glowing The other part should be lit when the test probe touches the second pin Testing high pressure sodium vapour tubes Touch tube with test probe A clear blue line within the arched tube indicates that the tube is in perfect...

Page 9: ...ntinuous sound of the buzzer indicates continuity The continuity test facility enables resistance tests between 0 and approx 5 MΩ The resistance value can be determined by the intensity and the sound level of the acoustic signal A higher sound level indicates a lower resistance value approx 0Ω Simultaneously the LED Continuity is illuminated Diode test procedure Touch contact Electrode see Fig 1 p...

Page 10: ...e carrying out this operation make sure you have disconnected the instrument from all connected circuits 1 Loosen the battery cover fastening screw and remove the cover see Fig 1 point 7 2 Remove the battery from the battery compartment 3 Insert one new battery of the same type 9V IEC 6LR61 Pay attention to the correct polarity 4 Position the battery cover back over the compartment and fasten it w...

Page 11: ...battery NEDA1604 JIS006P IEC6F22 Mechanical characteristics Dimensions LxWxH 255 x 60 x 40mm 10 x 2 x 1in Weight battery included approx 170g 5 ounces Safety standards Compliance with standard IEC EN61010 1 Insulation double insulation Overvoltage category CAT II 300V Max altitude 2000m 6562ft 7 3 ENVIRONMENT 7 3 1 Environmental conditions of use Reference calibration temperature 23 5 C 73 41 F Op...

Page 12: ...ot provided for in the instrument s specifications or in the instruction manual The content of this manual cannot be reproduced in any form without the manufacturer s authorization Our products are patented and our trademarks are registered The manufacturer reserves the right to make changes in the specifications and prices if this is due to improvements in technology 8 2 SERVICE If the instrument...