background image

   HT4010 

 

 

 

 

EN - 8

4.2  FUNCTION KEY DESCRIPTION 
4.2.1 HOLD 

key 

By pushing 

HOLD

 key the parameter’s measured value is frozen on the display and the 

symbol “HOLD” appears on it. Pushing 

HOLD

 key another time deactivates this mode. 

 

4.2.2 

 key 

By pushing and hold

 key for about  1s it’s possible to activate the backlight function on 

the display. By pressing and hold 

 key again for about  3s to exit from the function or 

waiting the automatically disable after about 20 seconds. The function is available on each 
position of the rotary selector. 
 

4.2.3 RANGE 

key 

By pushing 

RANGE

 key, the manual mode is activated and the “AUTO” symbol 

disappears from the display. Press 

RANGE 

cyclically to change the measuring range and 

fix the decimal point on the display. For reading more than the maximum range the “

OL

” 

indication is shown at display. To exit this function keep 

RANGE

 key pressed for at least 1 

second or rotate the selector to another position. This feature is disabled for AC current 
diode test and continuity test measurements. 
 

4.2.4 MAX 

key 

By pushing

 MAX

 key, maximum value are measured. The symbol corresponding “MAX” is 

displayed. This value is stored and automatically updated as soon as an higher value is 
measured by meter. Press 

MAX 

key again or rotate the selector to another position to exit 

from this function. This feature is disabled for resistance, diode test and continuity test 
measurements. 
 

4.2.5 MODE 

key 

By pushing 

MODE

 key the selection of a double measured functions which are present at 

display is possible. In particular this key is active only in 

/

 position to select among 

resistance test, diode test and continuity test. 
 
 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for HT4010

Page 1: ... Copyright HT ITALIA 2012 Release EN 1 01 03 02 2012 ENGLISH User manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ... 2 2 key 8 4 2 3 RANGE key 8 4 2 4 MAX key 8 4 2 5 MODE key 8 4 3 Functions of rotary switch description 9 4 3 1 DC Voltage measurement 9 4 3 2 AC Voltage measurement 10 4 3 3 AC Current measurement 11 4 3 4 Resistance measurement 12 4 3 5 Continuity test and Diode test 13 5 MAINTENANCE 14 5 1 General informations 14 5 2 Battery replacement 14 5 3 Cleaning 14 5 4 End of life 14 6 TECHNICAL SPECIFI...

Page 3: ...High Voltage ranger electrical shock risk Double insulated instrument AC Voltage or Current DC Voltage 1 1 PRELIMINARY This apparatus has been designed for use in an environment of pollution degree 2 Indoor use It measures CURRENT and VOLTAGE on category III up to 600V refer to ground plants For overvoltage categories please see paragraph 1 4 You must comply with the usual safety regulations aimed...

Page 4: ...rotection circuit excessive voltage would cause malfunctioning Before measuring current remove the voltage resistance test leads When measuring current any strong current near or close to the clamp jaw will affect the accuracy When measuring current always put the tested conductor in the middle of the clamp jaw in order to obtain a more accurate reading If the reading value or the sign indication ...

Page 5: ...n boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use and some other equipment for example stationary motors with permanent connection to fixed installation Measurement category II is for measurements performed on circuits directly connected to the low voltage installation Examples are measuremen...

Page 6: ...erfectly sinusoidal wave both families provide identical results In presence of distorted waves instead the readings are different Mean value instruments provide only the value of the fundamental wave while True RMS instruments provide the value of the entire wave including harmonics within the passband of the instrument Accordingly if the same quantity is measured with both kinds of instruments t...

Page 7: ...e tester please keep to the instructions given in paragraph 7 3 2 POWER SUPPLY The instrument is battery supplied One battery 9V IEC 1604 NEDA 6F22 are included in the package When battery is low the symbol BAT appears on the display Replace it immediately following the instructions given in paragraph 5 2 3 3 CALIBRATION The tester complies with the technical features listed in this manual Its per...

Page 8: ...or AC voltage detection without contact 3 Clamp trigger 4 Rotary function selector 5 HOLD key 6 backlight key 7 LCD display 8 MODE key 9 RANGE key 10 MAX key 11 COM input jack 12 VΩ input jack 13 Battery cover Fig 1 Instrument description www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 9: ...re than the maximum range the OL indication is shown at display To exit this function keep RANGE key pressed for at least 1 second or rotate the selector to another position This feature is disabled for AC current diode test and continuity test measurements 4 2 4 MAX key By pushing MAX key maximum value are measured The symbol corresponding MAX is displayed This value is stored and automatically u...

Page 10: ...ature see paragraph 4 2 3 If the voltage value under test is unknown select the highest range 3 Insert the red test lead plug into VΩ jack and the black test lead plug into COM jack 4 Connect the two long ends of test leads to the desired circuit see Fig 2 then reading will be displayed 5 OL message is shown at display if the DC voltage under test is over the maximum value that the instrument is a...

Page 11: ...bol is shown at display 3 Pressing the RANGE key to select the correct range or using the Autorange feature see paragraph 4 2 3 If the voltage value under test is unknown select the highest range 4 Insert the red test lead plug into VΩ jack and the black test lead plug into COM jack see Fig 3 5 Connect the two long ends of test leads to the desired circuit see Fig 3 then reading will be displayed ...

Page 12: ...A and 600A If the current value under test is unknown select the highest range Put the conductor to be tested inside to the clamp jaw see 2 Fig 4 then the current value is shown at display 3 OL message is shown at display the current under test is over the maximum value that the instrument is able to measure 4 For HOLD and MAX functions please refer to paragraph 4 2 www GlobalTestSupply com Find Q...

Page 13: ...ure see paragraph 4 2 3 If the resistance value under test is unknown select the highest range 3 Insert the red test lead plug into VΩ jack and the black test lead plug into COM jack 4 Connect the two long ends of test leads to the desired circuit see Fig 5 then reading value of resistance will be displayed 5 When OL symbol is displayed the resistance under test is over the maximum value that the ...

Page 14: ...the black test lead plug into COM jack and perform continuity test on the object on test see Fig 6 left side Buzzer emits sound if the measured resistance value is less about 150Ω 4 Pushing MODE key and select diode test The symbol is shown at display 5 Connect the red test leads to the anode of diode on test and the black test lead on the cathode ones see Fig 6 right side The correspondent thresh...

Page 15: ...t and trained technicians must perform this operation Remove the test leads or the conductor under test before replacing the battery 1 Rotate the switch on OFF 2 Remove the test leads or the objects to be tested 3 Remove the screw from the battery cover and detach the battery cover from the bottom cover 4 Remove the battery 5 Replace the battery with a same type new one 6 Replace the battery cover...

Page 16: ...ACrms 2 000V 0 001V 1 8 rdg 8dgt 20 00V 0 01V 200 0V 0 1V 600V 1V 2 5 rdg 8dgt AC Current Range Resolution Accuracy Frequency range Overload protection 2 000A 0 001A 2 5 rdg 10dgt 50 60Hz 600Arms 20 00A 0 01A 2 5 rdg 4dgt 200 0A 0 1A 600A 1A 4 0 rdg 8dgt Resistance and Continuity test Range Resolution Accuracy Buzzer Overload protection 200 0Ω 0 1Ω 1 0 rdg 4dgt 150Ω 600VDC ACrms 2 000kΩ 0 001kΩ 1 ...

Page 17: ...LCD with maximum reading 2000 points plus decimal point unit symbol indication and backlight Sample rate 2 times sec Conversion mode Mean value 6 2 ENVIRONMENTAL CONDITIONS 6 2 1 Climatic conditions Reference temperature 23 5 C 73 F 41 F Operating temperature 5 40 C 41 F 104 F Operating humidity 80 RH Storage temperature 20 60 C 4 F 140 F Storage humidity 80 RH This product conforms to the prescri...

Page 18: ... Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual cannot be reproduced in any form without our authorization Our products are patented Our logotypes are registered We reserve the right to modify ...

Reviews: