T2000-T2100
EN – 24
7.2.1. Reference guidelines
Safety: IEC/EN61010-1,
IEC/EN61010-2-032
EMC :
IEC/EN61326-1
Earth resistance :
IEC/EN61557-4 (partial), IEC60364-6 Appendix C.3
Leakage current (T2000): IEC/EN61557-13
Insulation: double
insulation
Pollution level:
2
Measurement category:
CAT IV 300V, CAT III 600V to earth, Max. 20A
7.2.2. General characteristics
Mechanical characteristics
Dimensions (L x W x H):
293 x 105 x 54mm (12 x 4 x 3in)
Weight (batteries included):
1120g (47 ounces)
Max cable size:
31mm (1in)
Max bars sizes:
55 x 31mm (2 x 1in)
Mechanical protection:
IP20
Power supply
Battery type:
4 x1.5V alkaline batteries LR6 AA MN1500
Low battery indication:
the display shows symbol “
”
Inner consumption:
<65mA
Auto Power OFF:
after 5 minutes of idleness
Display:
Characteristics:
4 LCD, decimal sign and point and backlight
Memory:
Memory capacity:
99 locations
Serial communication (T2100 only):
RS232 interface:
half-duplex, baud rate 4800
7.3. ENVIRONMENT
7.3.1. Environmental conditions for use
Reference temperature:
20°C ± 3°C ; (68°F ± 37°F)
Operating temperature:
0°C ÷ 40°C ; (32°F ÷ 104°F)
Allowable relative humidity:
10%RH ÷ 90%RH
Max operating altitude:
2000m ; (6562ft)
This instrument satisfies the requirements of Low Voltage Directive 2014/35/EU (LVD)
and of EMC Directive 2014/30/EU
This instrument satisfies the requirements of European Directive 2011/65/EU (RoHS)
and 2012/19/EU (WEEE)
7.4. ACCESSORIES
PROVIDED
Resistive test loops (1
, 5
, 10
)
RS232 communication cable (T2100)
Batteries
Rigid transport bag
ISO9000 calibration certificate
User
manual