HT7
EN - 11
5.6. CONTINUITY
TEST
CAUTION
Before taking the continuity test, disconnect the circuit under test from any
power source and discharge all capacitors.
Fig. 7: Continuity test
1. Perform the preliminary Autotest (see § 4.3).
2. Connect the L1 and L2 probes to the object under test (see Fig. 7)
3.
Continuity test is active for resistance <2
00k
. The instrument turns automatically on
along with LED
and the buzzer indicating a positive test.
The display and
bargraph values are not significant in this test and do not indicate the resistance
value of the object under test.
4. The instrument automatically turns off when the probes are separated from the object
under test or the applied voltage is lower than 3V DC.
5. Press the key to switch on the white LED illuminator to perform measurements in
dark environments.